17
Installation Instructions
1. If your hot water tank is electric, turn off the power to it to avoid damage to the element
in the tank.
2. If you have a private well, turn the power off to the pump and then shut off the main wa-
ter shut off valve. If you have municipal water, simply shut off the main valve. Go to the
faucet, (preferably on the lowest floor of the house) turn on the cold water until all pres-
sure is relieved and the flow of water stops.
3. Locate the softener tank and brine tank close to a drain where the system will be in-
stalled. The surface should be clean and level.
4. Connect the inlet and outlet of the softener using appropriate fittings. Perform all plumb-
ing according to local plumbing codes.
ON COPPER PLUMBING SYSTEMS BE SURE TO INSTALL A GROUNDING
WIRE BETWEEN THE INLET AND OUTLET PIPING TO MAINTAIN GROUND-
ING.
Any solder joints being soldered near the valve must be done before connecting any piping
to the valve. Always leave at least 6" (152 mm) between the control valve and joints being
soldered when soldering pipes that are connected to the valve. Failure to do this could
cause damage to the valve.
The Fusion NLT is equipped with 1” removable connectors. It is recommended that these
connectors are installed in the plumbing fitting using Teflon tape then lubricate the o-ring
on the connector remove the red clips and push them into the bypass valve once they are
tight in the plumbing fitting. The red clips can then be re-installed to secure the connectors
in the bypass valve.
The inlet and outlet can be identified on the bypass valve. There are arrows stamped in the
bypass valve showing flow (See page 19 diagram). The arrow pointing toward the valve is
the inlet and the arrow pointing away from the valve is the outlet.
All piping should be secured to prevent stress on the bypass valve and connectors.
Содержание FNLT-100-HY
Страница 5: ...5 System Dimensions 15 Brine Tank 17 04 ...
Страница 22: ...22 Visit us online at www USWaterSystems com Give us a call at 1 800 608 8792 Installation Instructions ...
Страница 25: ...25 Installation Overview ...
Страница 35: ...35 Main Repair Parts ...
Страница 38: ...38 Visit us online at www USWaterSystems com Give us a call at 1 800 608 8792 Control Valve Parts List ...
Страница 39: ...39 Power Head Exploded View ...
Страница 40: ...40 Visit us online at www USWaterSystems com Give us a call at 1 800 608 8792 Power Head Parts List ...
Страница 42: ...42 Visit us online at www USWaterSystems com Give us a call at 1 800 608 8792 ...