5
C
B
A
E
F
D
J
I
G
H
ADJACENT WALL
ADJ
A
CENT
W
ALL
K
N
L
L
O
P
M
THROUGH THE WALL
INSTALLATION
INTERIOR VERTICAL
INSTALLATION
FLOOR PROTECTOR CLEARANCES
K Back to Stove
U.S. 1 in (26 mm)
Canada 8 in (204 mm)
L
Side to Stove
U.S. 6 in (153 mm)
Canada 8 in (204mm)
M
Front to Stove
U.S. 6 in (153 mm)
Canada 8 in (204 mm)
N
Back to Flue
2 in (51 mm)
O
Overall Length
31 in (788 mm)
P
Overall Width
38 in (966 mm)
FLOOR PROTECTION
This heater must have a non-combustible floor protector (UL1618 ember protection) installed beneath it if the floor is of
combustible material. US: Floor protector should be UL listed or equal too, needs to extend 6” to the front, 6” to each side,
1” to the rear of the unit. Under and 2” beyond each side of the cleanout tee if an interior vertical instillation.
Canada: Floor protector should comply with CAN/ULC standards. Needs to extend 18” to the front, 8” beyond
each side of the unit.
Installation