DS1092-090
85
4.6
HARDWARE SETTINGS (DIP-SWITCH)
4.6.1 DOME SETTING
To set address, baud rate and communication protocol, remove the external and internal cover of the dome
as follows:
1. Rotate the external cover about ¼ turn counterclockwise to unlock it.
2. Rotate the internal cover about ¼ turn counterclockwise to unlock it.
3. After the two covers have been removed, it is possible to gain access to the dip-switches inside the
dome.
4. Perform the desired adjustments using the provided little screwdriver.
5. Place the internal cover on the stand until the fixing lugs of the dome match the holes on the stand and
rotate clockwise until it is locked.
6. Place the external cover on the stand and rotate it clockwise until it is locked.
4.6.2 ADDRESS SETTING
The dome THERA 5 is factory configured by default with address 1.
To change the address according to the connected devices, set the dipswitch on the dome electronic card,
following the example in the figure.
DEFAULT SETTING
1 2
ON
3
4
5
6 7 8
ON
1
2
3
4
5
6
7
8
1
2
8
128
64
16
4
32
DIP-SWITCH