DS1092-090
54
WALL MOUNTING WITH POWER BOX REF. 1092/628 (not provided)
Before starting installation, check that all devices to be connected are not powered.
Make the holes on the support base and fix the Power Box using the 4 holes on the device ends.
With a Phillips screwdriver unscrew the 4 screws on the Power Box front unit in order to open it and
make the following connections.
When the Power Box is open, make the connections for the RS485 line. Insert in the largest hole on the
lower side, provided with grommet, a 2-wire cable of suitable length and section (see Requirements for
connection cables). This cable must be connected to terminal pins AA (+) and BB (-) on the card.
Connect the video signal RG cable by putting the cable of suitable length and type (see Requirements
for connection cables) in the largest hole provided with grommet, present on the lower side of the Power
Box (the same used for RS485 line) and connect it to the BNC connector present in the cable provided
with the Power Box.
UNSCREW TO OPEN
UNSCREW TO OPEN
Содержание THERA 5 Ref.1092/602
Страница 90: ...DS1092 090 90 NOTE...
Страница 91: ...DS1092 090 91 NOTE...