background image

IN WHICH CONFIGURATION DO YOU USE TRANSIT?

Door 1 controlled by channel 1

Door 2 controlled by channel 2

GO TO PAGE N° 8

Door 1 controlled by channel 

1

Door 2 controlled by the 

proximity key or the proximity 

key integrated in the remote 

control

GO TO PAGE N°10

Door 1 controlled by the 

proximity key or the proximity 

key integrated in the remote 

control

Door 2 controlled by channel 2

GO TO PAGE N°12

Door 1 and Door 2 controlled 

by the proximity key or the 

proximity key integrated in the 

remote control

GO TO PAGE N°14

1

2

3

4

7

50-000-611 DOC TRANSIT GB FDI 

C

Содержание FDI Transit FD-010-012

Страница 1: ...VIEW TECHNICALFEATURES OPERATING PRINCIPLES IN WHICH CONFIGURATION DO YOU USE TRANSIT CONFIGURATION N 1 CONFIGURATION N 2 CONFIGURATION N 3 CONFIGURATION N 4 CONTROLLER PARAMETERS PROGRAMMATION WIRING...

Страница 2: ...nts of the European Community Directive R TTE 99 5 CE Assessment of the product s compliance with requirements based on the following standards Regarding short range devices ETS300683 1997 Regarding r...

Страница 3: ...be accessed The system consists of the following parts SPARE PARTS FORTRANSIT 500 GB 100 020 TRANSIT 500 KEYS WITHOUT RF433 FD 020 080 TRANSIT INT MULLION READER FD 020 084 VANDAL RESISTANT READER FD...

Страница 4: ...10 to 20m coaxial 50 35 m More than 20m of cable less than 35m 1 2 3 4 5 6 7 8 9 10 1112131415161718 19 20 1 Way for wires 2 Buttons for programming 3 3 digit display 4 Programming reader 5 Fixing hol...

Страница 5: ...f a proximity reader connected to door 1 In programming mode indicates access authorisation for door 2 In operation indicates the door opening by a code Power Supply status Dot on correct power supply...

Страница 6: ...t is held for one second 5 Access Authorization The numbers 01 to 500 or 01 to 999 depending on the version correspond to locations in which you can store the access authorisation of a remote control...

Страница 7: ...mity key or the proximity key integrated in the remote control GO TO PAGE N 10 Door 1 controlled by the proximity key or the proximity key integrated in the remote control Door 2 controlled by channel...

Страница 8: ...supply RFAntenna433MHz inoption Coaxcable 50Ohms10mmax Diameter6 10 500mmaxlength Power supply DC power supply 12V DC 0 4 A acceptable range 10 8V to 22V AC power supply 12V AC 12V in nominal value a...

Страница 9: ...ition contains a code at least one of the points on the left or the right of the display lights up To modify the authorisation press Present the remote control on the reading zone on the right of the...

Страница 10: ...oor1 ExitPB Door2 ExitPB Power supply RFAntenna433MHz inoption Coaxcable 50Ohms10mmax Diameter6 10 500mmaxlength Diameter6 10 100mmaxlength Door 1 controlled by channel 1 Door 2 controlled by the prox...

Страница 11: ...the authorisation press Present the remote control or the proximity key on the reading zone on the right of the readout After the code has been read the central point lights up If the code already ex...

Страница 12: ...oor1 ExitPB Door2 ExitPB Power supply RFAntenna433MHz inoption Coaxcable 50Ohms10mmax Diameter6 10 500mmaxlength Diameter6 10 100mmaxlength Door 1 controlled by the proximity key or the proximity key...

Страница 13: ...horisation press Present the remote control or the proximity key on the reading zone on the right of the readout After the code has been read the central point lights up If the code already exists in...

Страница 14: ...lay Door2 Door1 ExitPB Door2 ExitPB Power supply Diameter6 10 500mmaxlength Diameter6 10 100mmaxlength Diameter6 10 100mmaxlength Notconnected Door 1 and Door 2 controlled by the proximity key or the...

Страница 15: ...ode at least one of the points on the left or the right of the display lights up To modify the authorisation press Present the proximity key on the reading zone on the right of the display After the c...

Страница 16: ...now the existing password Enter programming mode Display function F1 using and keys Hold the key pressed down for 1 second the display flashes once and the password is deleted 2 Function F2 State of P...

Страница 17: ...ys then validate using the key If the memory is a 2KS 500 keys version a message DIF advise that only the 500 first keys will be copied The display indicates 1 2 which means a copy of the main memory...

Страница 18: ...2V DC Fail Secure Lock In case of alternative current power supply use a variable resistor instead of a diode Use a power supply suitable for the fail safe lock We strongly recommend using a separate...

Страница 19: ...ply to keep the door locked For instance in the event of power failure the door would become unlocked Controlling a fail safe lock Door 1 Terminal n 8 common Terminal n 9 idle Door 2 Terminal n 16 com...

Отзывы: