SPECIFICATION 

 
The main technical features of the 1092/679 cameras are summarised below. 
 

General features

 

Value 

Camera module 

Sony CMOS IMX238 1/2.8” 

Resolution 

720p / 1080p

 

Sensitivity (lux) 

0.2 Lux color / 0.02Lux B/W, F1.6

 

IR Cut mechanic filter 

YES 

 

Lens 

Value 

Optical Zoom  

20X, f=3.5mm – 94.5mm 

Digital Zoom  

NO 

 

Features of the camera

 

Value 

IR light 

LED Array 

IR lighting control 

Manual / Automatic 

IR light maximum range 

100 m 

Working temperature (with heating  and fan)  

-30 

÷

 55ºC 

Working temperature (inside housing) 

÷

 50ºC 

Electricity 

24Vac / 3A, 50/60Hz 

Consumption 

<10W 

Included power supply 

YES 

 

Function 

Value 

On screen menu 

YES 

Preset number 

128 

Vector  Scan  function  (functions  sequence 
and available Preset) 

7 Vector Scan  

Pattern function (settable patterns)  

 

 

Auto 

Scan 

function 

(360° 

horizontal 

movement) 

YES 

Supported protocol 

RS-485 ; PELCO D 

Menu Supported alarm management 

8  

In-Out remote alarms 

8In/1Out 

Alarm options 

Vector Scan-Pattern-Auto Scan -Preset 

Compatibility with additional alarm board (Sch 
1092/685 or 1092/709) 

YES 

Additional  functions  available  with  remote 
alarm board  

8 Preset di allarme 

 

Содержание Easy Dome 1092/605

Страница 1: ...DS1092 229 Mod 1092 EASY DOME CAMERA AHD 20X WITH IR ILLUMINATOR Ref 1092 679 USER AND INSTALLATION MANUAL...

Страница 2: ...g functions 13 5 4 5 Preset positions PROGRAM and recalling 13 5 5 Function programming menu 14 5 5 1 Product information menu 15 5 5 2 Display options menu DISPLAY OPTIONS Settings for texts that can...

Страница 3: ...s are listed below Designed for easy and quick installation Sony CMOS IMX238 1 2 8 sensor Sensitivity 0 2 Lux color 0 02Lux B W F1 6 Resolution 720p or 1080p selectable 360 degrees horizontal rotation...

Страница 4: ...the instructions shown in the installation manual Electrical power A switch for performing maintenance operations on the camera must be included Connect the camera only to the electrical power supply...

Страница 5: ...away from rain and dust Do not touch the zoom lens with your fingers If needed use a soft cloth and methylated spirit to remove traces of dust Apply a specific cap to protect the zoom lens when the ca...

Страница 6: ...nstalling Urmet Domus 1092 679 These instructions assume that the installer has a good knowledge of installation techniques and is capable of adopting safe installation methods 4 1 EASY DOME MINIMUM C...

Страница 7: ...acket providing a suitable protection conduit for the cables Insert the connection cables power video data inside of the bracket until they exit from the opposite side Fasten the bracket to the dome s...

Страница 8: ...to maintain the IP protection grade Don t supply the Power Box before the end of the installation Connect the RS485 serial line to AA BB terminal pins Conncet the cables of the alarm sensors to A1 A8...

Страница 9: ...the configuration switch Follow the configuration settings for Easy Dome correct functioning see paragraph Dome settings Close the metal cover 4 1 3 CABLES SPECIFICATIONS The system requires 3 types o...

Страница 10: ...n Display protocol communication parameters camera address and software version EASY DOME 1092 679 CAMERA CTU20AM108 ADDRESS 1 BAUDRATE 2400 PROTOCOL AUTO VERSION 1 0 S N 064501 INITIALIZING Settings...

Страница 11: ...e operation in progress in this way it is possible to start another one or send a command Using a single key Pressing a single key can cause camera action For example the following command will zoom o...

Страница 12: ...camera horizontally clockwise and tip it leftwards to turn it anticlockwise If no advanced options are set e g range limits set and enabled the camera can be turned continuously without interruptions...

Страница 13: ...y direct commands on the keyboards Presets from 192 to 225 can be managed only by direct commands on the keyboards The manual focusing and iris opening settings cannot be stored The following examples...

Страница 14: ...enu simply use CLOSE 1092 621 or IRIS 1092 693 controls also displayed as IRIS in the menus to go back to the previous level menu If you want to exit definitively any level menus simply use the CLOSE...

Страница 15: ...and crosshair Option Value Explanation CAMERA NAME SETUP This operation makes it possible to assign a name to the Easy Dome Pressing IRIS twice accesses the screen page for naming of the device COORD...

Страница 16: ...s for tilt function are reversed V SCAN STILL NA NOT AVAILABLE AUTO FOCUS Z PTZ OFF If activated the Dome will automatically perform the control of images focusing If activated with PTZ the Dome will...

Страница 17: ...ON the Dome tilt limit increases of 5 degrees going from 90 to 95 SPEED LIMIT ON OFF If active with ON limits Dome speed of movement to half the maximum speed IRLED CONTROL It permits to set the mode...

Страница 18: ...ing mode enter the serial number below S N 211237 Device serial number RETURN Exits the OSD menu IR LED CONTROL submenu of the CONTROL OPTIONS menu Option Value Explanation IR LED MODE AUTO ON OFF Sel...

Страница 19: ...D FOCUS submenu Option Value Explanation ZOOM SPEED 1 8 NOT AVAiLABLE DIGITAL ZOOM ON OFF NOT AVAiLABLE AF SENSITIVITY LOW HIGH This option allows to change the sensitivity level of the Auto Focus fun...

Страница 20: ...ing time is fixed to 1 50 second o The autoiris opening is manually varied in the BRIGHT LEVEL menu o Gain control is off 0 dB SLOW SHUTTER ON OFF This function if enabled ON increases the dome sensit...

Страница 21: ...180 vertical rotation H MIRROR ON OFF If enabled ON this function allows to see the images horizontally flipped 180 horizontal rotation D N MODE AUTO COLOR B W The opening and closing of the IR filter...

Страница 22: ...age STORED CALL PRESET This operation allows to recall a stored preset DELETE PRESET This operation allows to delete a stored preset After selecting the preset to be deleted press IRIS and confirm aga...

Страница 23: ...le to define the action kind the number to which it is associated the movement speed and the dwelling time see below RUN A VECTORSCAN This option allows to start the selected VectorScan DELETE A VECTO...

Страница 24: ...n and press again IRIS to confirm the pattern storage RUN This option allows to store the patterns Press IRIS and select with the joystick the frame to be stored press again IRIS to confirm the patter...

Страница 25: ...define the TILT end position With the joystick select the zone end position and confirm with IRIS The coordinates will be automatically stored by the dome NAME This option permits identification of th...

Страница 26: ...1 64 VECTORSCAN 1 7 PATTERN 1 6 PANSCAN 1 AUTOSCAN 1 Allows to select the action to be carried out after power on The selectable value associated to the single action changes according to the previou...

Страница 27: ...d see below Option Value Explanation PAN START POSITION 0 0 359 9 0 0 90 0 This option allows to store the PAN TILT start position coordinates for the zone By pressing IRIS and selecting with the arro...

Страница 28: ...U OF FUNCTION PROGRAM This function determines a continuous movement between two points selected by user Option Value Explanation START POINTER Allows to memorize the coordinates before starting funct...

Страница 29: ...es previously described functions ACTION PATTERN PANSCAN AUTOSCAN PRESET VECTORSCAN Allows to select the action to be associated to each of the available alarm contacts NUMBER PRESET 1 64 VECTORSCAN 1...

Страница 30: ...asswords Master and Operator to access the menu PASSWORD MANAGEMENT The MASTER password first level allows to access USER ADMIN menu and enables the password holder Administrator to lock unlock action...

Страница 31: ...ion allows to make again active all the dome factory settings RESOLUTION 720P 25 720P 30 1080P 25 1080P 30 This option permits to select the video resolution DOME RESTART This option permits to restar...

Страница 32: ...ogram presets CALL PRESET ON OFF If enabled ON this option allows the user to use presets CAMERA SETUP ON OFF If enabled ON this option allows the user to change the dome operation parameters SET PATT...

Страница 33: ...the parameters about Protocol and Baud Rate Dip Switch Protocol 1st Dip 2nd Dip Auto OFF OFF DYNACOLOR ON OFF Dip Switch Baud rate 3rd Dip 4th Dip 2400 OFF OFF 4800 ON OFF 9600 OFF ON 19200 ON ON ON 1...

Страница 34: ...OFF OFF OFF ON OFF OFF OFF 18 OFF ON OFF OFF ON OFF OFF OFF 19 ON ON OFF OFF ON OFF OFF OFF 20 OFF OFF ON OFF ON OFF OFF OFF 21 ON OFF ON OFF ON OFF OFF OFF 22 OFF ON ON OFF ON OFF OFF OFF 23 ON ON O...

Страница 35: ...74 PRESET PRESET 74 ENTER Enables the white balance in outdoor mode 75 SHOT SHOT 75 ENTER Enables the ATW Auto Tracing White balance function 75 PRESET PRESET 75 ENTER Enables the white balance One P...

Страница 36: ...8 alarm input activation 179 SHOT SHOT 179 ENTER Simulates the N 9 alarm input activation 180 SHOT SHOT 180 ENTER Simulates the N 10 alarm input activation 181 SHOT SHOT 181 ENTER Simulates the N 11...

Страница 37: ...e with heating and fan 30 55 C Working temperature inside housing 0 50 C Electricity 24Vac 3A 50 60Hz Consumption 10W Included power supply YES Function Value On screen menu YES Preset number 128 Vect...

Страница 38: ...uto flip YES Waterproof level IP66 Remote control Value Interface RS485 Protocol Pelco D Data rate 2400bps 4800bps 9600bps 19200bps selezionabili tramite dip switch IMPORTANT NOTE Technical features m...