background image

DS1092-229

 

27

 

 

5.5.8 

POWER ON ACTION  SUBMENU OF  MOTION SUBMENU 

 

 

 

Option 

Value 

Explanation 

ACTION 

NONE/PRESET/VECTORSCAN/ 

PATTERN/PANSCAN/AUTOSCAN 

This option allows to select the action to be activated. 

NUMBER 

PRESET:      1/64 

VECTORSCAN:  1/7 

PATTERN:    1/6 

PANSCAN:     1 

AUTOSCAN:    1 

This  option  allows  to  define  in  detail  which  single  action 
has  to be activated.  The single  action  number  that can  be 
selected  changes  according  to  the  previously  selected 
action  (from  1  to  255,  except  the  not  programmable  ones 
for the Presets; from 1 to 6 for VectorScan; from 1 to 3 for 
Patterns, 1 for PanScan, 1 for AutoScan). The selection of 
the  desired  number  is  possible  by  pressing  the  button 
IRIS+ and going to the respective screen.  

RETURN 

 

Closes OSD menu. 

 
 

5.5.9 

LIMIT OPERATION SUBMENU OF MOTION SUBMENU 

 

This option allows to reduce the dome operation limit, according to the previously indicated action to be automatically 
performed (see below). 

 
 

 

 
 

Option 

Value 

Explanation 

PAN START POSITION 

0,0 ÷ 359,9  ÷ 0,0 ÷ 90,0 

This option allows to store the PAN/TILT start position 
coordinates for the zone. By pressing IRIS+ and selecting with 
the arrow buttons the end position frame to be stored for the 
zone, it is possible to see on the monitor also the coordinates 
of the displayed frame. Press again IRIS+ to confirm the zone 
start position storing.        

PAN END POSITION 

0,0 ÷ 359,9  ÷ 0,0 ÷ 90,0 

This  option  allows  to  store  the  PAN/TILT  zone  final 
coordinates.  By  pressing  IRIS+  and  selecting  with  the  arrow 
buttons  the  end  position  frame  to  be  stored  for  the  zone,  it  is 
possible  to  see  on  the  monitor  also  the  coordinates  of  the 
displayed  frame.  Press  again  IRIS+  to  confirm  the  storing  of 
the zone end position. 

DIRECTION 

LEFT/RIGHT 

This  option  allows  to  select  the  motion  direction  of  the  dome 
(Left, Right). 

OPERATION 

ON/OFF 

If set to ON, this option allows to activate the function.   

RETURN 

 

Closes OSD menu. 

 
 

POWER ON ACTION 

 

1 Action       OFF 
2 Number            1 
3 Return 

LIMIT OPERATION 

 

1 Pan Start Position  0.0 
2 Pan End Position    0.0 
3 Direction           Right 
4 Operation           OFF 
5 Return 

Содержание Easy Dome 1092/605

Страница 1: ...DS1092 229 Mod 1092 EASY DOME CAMERA AHD 20X WITH IR ILLUMINATOR Ref 1092 679 USER AND INSTALLATION MANUAL...

Страница 2: ...g functions 13 5 4 5 Preset positions PROGRAM and recalling 13 5 5 Function programming menu 14 5 5 1 Product information menu 15 5 5 2 Display options menu DISPLAY OPTIONS Settings for texts that can...

Страница 3: ...s are listed below Designed for easy and quick installation Sony CMOS IMX238 1 2 8 sensor Sensitivity 0 2 Lux color 0 02Lux B W F1 6 Resolution 720p or 1080p selectable 360 degrees horizontal rotation...

Страница 4: ...the instructions shown in the installation manual Electrical power A switch for performing maintenance operations on the camera must be included Connect the camera only to the electrical power supply...

Страница 5: ...away from rain and dust Do not touch the zoom lens with your fingers If needed use a soft cloth and methylated spirit to remove traces of dust Apply a specific cap to protect the zoom lens when the ca...

Страница 6: ...nstalling Urmet Domus 1092 679 These instructions assume that the installer has a good knowledge of installation techniques and is capable of adopting safe installation methods 4 1 EASY DOME MINIMUM C...

Страница 7: ...acket providing a suitable protection conduit for the cables Insert the connection cables power video data inside of the bracket until they exit from the opposite side Fasten the bracket to the dome s...

Страница 8: ...to maintain the IP protection grade Don t supply the Power Box before the end of the installation Connect the RS485 serial line to AA BB terminal pins Conncet the cables of the alarm sensors to A1 A8...

Страница 9: ...the configuration switch Follow the configuration settings for Easy Dome correct functioning see paragraph Dome settings Close the metal cover 4 1 3 CABLES SPECIFICATIONS The system requires 3 types o...

Страница 10: ...n Display protocol communication parameters camera address and software version EASY DOME 1092 679 CAMERA CTU20AM108 ADDRESS 1 BAUDRATE 2400 PROTOCOL AUTO VERSION 1 0 S N 064501 INITIALIZING Settings...

Страница 11: ...e operation in progress in this way it is possible to start another one or send a command Using a single key Pressing a single key can cause camera action For example the following command will zoom o...

Страница 12: ...camera horizontally clockwise and tip it leftwards to turn it anticlockwise If no advanced options are set e g range limits set and enabled the camera can be turned continuously without interruptions...

Страница 13: ...y direct commands on the keyboards Presets from 192 to 225 can be managed only by direct commands on the keyboards The manual focusing and iris opening settings cannot be stored The following examples...

Страница 14: ...enu simply use CLOSE 1092 621 or IRIS 1092 693 controls also displayed as IRIS in the menus to go back to the previous level menu If you want to exit definitively any level menus simply use the CLOSE...

Страница 15: ...and crosshair Option Value Explanation CAMERA NAME SETUP This operation makes it possible to assign a name to the Easy Dome Pressing IRIS twice accesses the screen page for naming of the device COORD...

Страница 16: ...s for tilt function are reversed V SCAN STILL NA NOT AVAILABLE AUTO FOCUS Z PTZ OFF If activated the Dome will automatically perform the control of images focusing If activated with PTZ the Dome will...

Страница 17: ...ON the Dome tilt limit increases of 5 degrees going from 90 to 95 SPEED LIMIT ON OFF If active with ON limits Dome speed of movement to half the maximum speed IRLED CONTROL It permits to set the mode...

Страница 18: ...ing mode enter the serial number below S N 211237 Device serial number RETURN Exits the OSD menu IR LED CONTROL submenu of the CONTROL OPTIONS menu Option Value Explanation IR LED MODE AUTO ON OFF Sel...

Страница 19: ...D FOCUS submenu Option Value Explanation ZOOM SPEED 1 8 NOT AVAiLABLE DIGITAL ZOOM ON OFF NOT AVAiLABLE AF SENSITIVITY LOW HIGH This option allows to change the sensitivity level of the Auto Focus fun...

Страница 20: ...ing time is fixed to 1 50 second o The autoiris opening is manually varied in the BRIGHT LEVEL menu o Gain control is off 0 dB SLOW SHUTTER ON OFF This function if enabled ON increases the dome sensit...

Страница 21: ...180 vertical rotation H MIRROR ON OFF If enabled ON this function allows to see the images horizontally flipped 180 horizontal rotation D N MODE AUTO COLOR B W The opening and closing of the IR filter...

Страница 22: ...age STORED CALL PRESET This operation allows to recall a stored preset DELETE PRESET This operation allows to delete a stored preset After selecting the preset to be deleted press IRIS and confirm aga...

Страница 23: ...le to define the action kind the number to which it is associated the movement speed and the dwelling time see below RUN A VECTORSCAN This option allows to start the selected VectorScan DELETE A VECTO...

Страница 24: ...n and press again IRIS to confirm the pattern storage RUN This option allows to store the patterns Press IRIS and select with the joystick the frame to be stored press again IRIS to confirm the patter...

Страница 25: ...define the TILT end position With the joystick select the zone end position and confirm with IRIS The coordinates will be automatically stored by the dome NAME This option permits identification of th...

Страница 26: ...1 64 VECTORSCAN 1 7 PATTERN 1 6 PANSCAN 1 AUTOSCAN 1 Allows to select the action to be carried out after power on The selectable value associated to the single action changes according to the previou...

Страница 27: ...d see below Option Value Explanation PAN START POSITION 0 0 359 9 0 0 90 0 This option allows to store the PAN TILT start position coordinates for the zone By pressing IRIS and selecting with the arro...

Страница 28: ...U OF FUNCTION PROGRAM This function determines a continuous movement between two points selected by user Option Value Explanation START POINTER Allows to memorize the coordinates before starting funct...

Страница 29: ...es previously described functions ACTION PATTERN PANSCAN AUTOSCAN PRESET VECTORSCAN Allows to select the action to be associated to each of the available alarm contacts NUMBER PRESET 1 64 VECTORSCAN 1...

Страница 30: ...asswords Master and Operator to access the menu PASSWORD MANAGEMENT The MASTER password first level allows to access USER ADMIN menu and enables the password holder Administrator to lock unlock action...

Страница 31: ...ion allows to make again active all the dome factory settings RESOLUTION 720P 25 720P 30 1080P 25 1080P 30 This option permits to select the video resolution DOME RESTART This option permits to restar...

Страница 32: ...ogram presets CALL PRESET ON OFF If enabled ON this option allows the user to use presets CAMERA SETUP ON OFF If enabled ON this option allows the user to change the dome operation parameters SET PATT...

Страница 33: ...the parameters about Protocol and Baud Rate Dip Switch Protocol 1st Dip 2nd Dip Auto OFF OFF DYNACOLOR ON OFF Dip Switch Baud rate 3rd Dip 4th Dip 2400 OFF OFF 4800 ON OFF 9600 OFF ON 19200 ON ON ON 1...

Страница 34: ...OFF OFF OFF ON OFF OFF OFF 18 OFF ON OFF OFF ON OFF OFF OFF 19 ON ON OFF OFF ON OFF OFF OFF 20 OFF OFF ON OFF ON OFF OFF OFF 21 ON OFF ON OFF ON OFF OFF OFF 22 OFF ON ON OFF ON OFF OFF OFF 23 ON ON O...

Страница 35: ...74 PRESET PRESET 74 ENTER Enables the white balance in outdoor mode 75 SHOT SHOT 75 ENTER Enables the ATW Auto Tracing White balance function 75 PRESET PRESET 75 ENTER Enables the white balance One P...

Страница 36: ...8 alarm input activation 179 SHOT SHOT 179 ENTER Simulates the N 9 alarm input activation 180 SHOT SHOT 180 ENTER Simulates the N 10 alarm input activation 181 SHOT SHOT 181 ENTER Simulates the N 11...

Страница 37: ...e with heating and fan 30 55 C Working temperature inside housing 0 50 C Electricity 24Vac 3A 50 60Hz Consumption 10W Included power supply YES Function Value On screen menu YES Preset number 128 Vect...

Страница 38: ...uto flip YES Waterproof level IP66 Remote control Value Interface RS485 Protocol Pelco D Data rate 2400bps 4800bps 9600bps 19200bps selezionabili tramite dip switch IMPORTANT NOTE Technical features m...

Отзывы: