urmet domus 1083/58 Скачать руководство пользователя страница 12

12 

−−−−

 

sec. 4e

2 VOICE - Technical Manual

CALL FORWARDING DEVICE

b.  now press the button  3  to be programmed and wait for a 

con

fi

 rmation tone from the indoor station.

BEEP

3

 

4.  On your smartphone, open the pedestrian access door. 

 

5.  On the indoor station: 

a. a beep sound will con

fi

 rm that programming has been 

successfully completed;

b.  now hook up the handset of the indoor station - which will 

beep to con

fi

 rm programming mode quitting. 

 

6.  On your smartphone, end the current conversation. 

 

7.  To check the programmed function:

a.  lift the handset off the hook at the indoor station and press 

the programmed key;

b.  check for the presence of the call on your smartphone and 

of a voice feedback when you answer.

 

For intercom call programming in the following video door 

phone models:

 

mod. Aiko   ref. 1716/1 and 1716/2

 

mod. Modo  ref. 1717/12H

 

please refer to the chapter“(Audio/Video) Settings \ Video 

door phone directory \ Adding a record to the directory” 

contained in the instruction manual supplied with the 

product.

TECHNICAL SPECIFICATIONS

Input voltage from BUS line: ...................................................

48 V 

 

External input voltage:  ...........................................................  

24 V 

  

Maximum absorption:  ...........................................................  

200 mA

Absorbed power in operation:  .............................................. 

max 6 W

Operating temperature: .....................................................

-5 ÷ +45 °C

23 ÷ +113 °F

Max humidity: .........................................................................

95% RH

Ethernet interface: ..........................................................

10/100 Mbps

Wi-Fi:  ...............................

2.4 Ghz (conforms to IEEE 802.11 b/g/n)

with internal antenna

Dimensions (LxHxD): ................

140 (~8 DIN modules) x 90 x 60 mm

5.51 x 3.54 x 2.36”

  The product is designed to be powered off a BUS 

line or external supply Ref. 1083/24, via 24V (6 W,

 24 

V  ) terminals, with power supply up to the 

speci

fi

 

ed power source requirements (LPS) and 

protected against short circuits and overcurrents

  according to EN 60950-1:2006+A11+A1+A12+A2

 provisions.

KEY TO SYMBOLS

Symbol Description

       

 

Direct input voltage

Video door phone system trademark

       

DANGER - Presence of safety-critical components

 

CONNECTION DIAGRAMS

SYSTEM WITH CALL FORWARDING DEVICE 

POWERED OFF BUS LINE

IN-OUT connection on the call forwarding device.

SV124-1315

2

2

2

JP  V.INT/V.EXT.: V.INT

JP Z: OFF

A1

C

B

D

E

F

DIP1: OFF

MASTER

LINE

2

LINE

1

3

LINE

LINE

4

LINE OUT

LINE IN

24Vdc

-

+

LAN

LINE

OUT

IN

LINE

LINE

IN

CP

S-

S+

LINE

OUT

CFW

IN-OUT connection on the video door phone.

SV124-1312

DIP1: OFF

MASTER

2

2

2

2

2

2

JP  V.INT/V.EXT.: V.INT

JP Z: ON

A

C

D

A

F

E

A

B

LINE

2

LINE

1

3

LINE

LINE

4

LINE OUT

LINE IN

LINE

IN

CP

S-

S+

LINE

OUT

24Vcc

-

+

LAN

LINE

OUT

IN

LINE

LINE

IN

CP

S-

S+

LINE

OUT

CFW

LINE

IN

CP

S-

S+

LINE

OUT

KEY TO DIAGRAMS

A

Video door phone mod. Miro for 2Voice Adapter for 

video door phone (IN-OUT connection) Ref. 1750/50

A1

Video door phone mod. Miro for 2Voice system

B

To router/modem ADSL or 3G/4G

C

Optional: 

fl

 oor call button

CFW

Call Forwarding device for 2Voice system Ref. 1083/58

D

From the riser column

E

To the riser column

F

4-user distributor Ref. 1083/55

CALL FORWARDING DEVICE FOR 2 VOICE SYSTEM Ref. 1083/58

TECHNICAL SPECIFICATIONS - CONNECTION DIAGRAMS

Содержание 1083/58

Страница 1: ...N FROM THE Urmet CallMe APP 6 CONFIGURATION MENU 8 Urmet CallMe CONFIGURATION MENU 8 DEVICE INSTALLATION 9 Download from www urmet com Technical Manuals area SECTION CONTENTS IN A CONTROL PANEL 9 WALL...

Страница 2: ...w camera By clicking on View camera you can see your visitor s picture before answering the call This feature is particularly useful when you wish to make sure who is at the door before taking any act...

Страница 3: ...he name that is displayed in the top left corner i e the name of your account Although the View camera window may appear in the middle of the black window even if you try selecting it no camera pictur...

Страница 4: ...ailable for reference and you will be able to access the instruction booklet full version of the device Info page 3 By pressing the Settings key you will display the following page 1 3 2 Settings page...

Страница 5: ...will be referred to the Home Page where a few minutes later the green dot will be displayed with a closed chain to indicate that connection was successfully established Home page USE A SAVED ACCOUNT S...

Страница 6: ...ng Instructions After selecting Continue you must turn on the Wi Fi on your mobile phone and access the Wi Fi network created by the device Key in the suggested password WARNING Do not forget to enter...

Страница 7: ...ically switched off daily e g nightly from 11 00 P M until 7 00 A M during these intervals the LED on the Call Forwarding Device will be lit steady orange light Wi Fi Switch off Intervals After settin...

Страница 8: ...you will be ready to start using the application CONFIGURATION MENU Urmet CallMe CONFIGURATION MENU App Configuration Menu Optionally the Urmet CallMe application can help you to Limit incoming calls...

Страница 9: ...heck that your smartphone data plan does not require VoIP data flow locking WARNING Applications that optimise the use of the battery ensure energy saving for your smartphone protect the device antivi...

Страница 10: ...on in the configuration mode Steady green light the device has been correctly registered with the Urmet SIP server and is ready to forward calls to a smartphone Flashing green light the device is conn...

Страница 11: ...e termination must be activated on a device connected at the end of a line without a new section restarting from the LINE OUT terminals Termination on DEFAULT Termination off 8 Dip switch CODE they de...

Страница 12: ...DIN modules x 90 x 60 mm 5 51 x 3 54 x 2 36 The product is designed to be powered off a BUS line or external supply Ref 1083 24 via 24V 6 W 24 V terminals with power supply up to the specified power s...

Страница 13: ...s that can be switched on via the Bus line are reported and on those that are surplus a local power supply Ref 1083 24 is required TECHNICAL DATA Power supply 100 240 Vac 50 60 Hz Power max 12 W Secon...

Страница 14: ...14 sec 4e 2 VOICE Technical Manual CALL FORWARDING DEVICE...

Отзывы: