TECHNICAL SPECIFICATIONS
Weight without bag
Max fog emission in a single shot
Total fog emission capacity x bag
Fog bag capacity
Working time without mains power
Average power consumption during heating
Heating time
Average power consumption range
Maximum current consumption at 12 V
Batteries type suggested
Cover tamper
RTC real time clock
5
The “empty” signal does not mean only that the bag is empty,
but also warns that the system has shot at least 100 seconds (Modular 2 CPlus)
or 80 seconds (Modular 3 Cplus).Warning : press “RESET” button only when you
actually exchange the bag or you will lose the seconds counting.
WARNING :
- Do not disconnect the machine immediately after the shot
- Change the battery every two years
- Change the bag as soon as the “empty” signal appears
- The generator must have the side holes free for air ventilation
8 Kg
200 m
3
750 ml
2 hours
170 W + 10
120 minutes
37- 41 W
1,2 A
Pb 2 Ah 12V
microswitch
Yes
800 m
3
Pb 2 Ah 12V
MODULAR 2 PLUS
300 m
3
Pb 2 Ah 12V
MODULAR 3 PLUS
400 m
3
Pb 2 Ah 12V
MODULAR 4 PLUS
500 m
3
Pb 2 Ah 12V
MODULAR 5 PLUS
MODULAR 8 PLUS
9 Kg
10 Kg
10 Kg
11 Kg
1250 m
3
1250 m
3
1700 m
3
1700 m
3
1700 m
3
750 ml
1000 ml
1000 ml
1000 ml
2 hours
2 hours
2 hours
2 hours
170 W + 10
280 W + 10
280 W + 10
280 W + 10
120 minutes
140 minutes
140 minutes
150 minutes
37 - 41 W
42 - 47 W
42 - 47 W
48 - 53 W
1,4 A
1,7 A
1,9 A
2,1 A
microswitch
microswitch
microswitch
microswitch
Yes
Yes
Yes
Yes
LAN & WIFI board support
Yes
Yes
Yes
Yes
Yes
16
14
DEFECTS POSSIBLE SOLUTION
DEFECT FOUND POSSIBLE CAUSE POSSIBLE SOLUTION
Disturbance/ interference
or potential differences
between devices
In the evenience of high noise on mains power
(lightings) an error while reading thermocouple
values can occur. Execute a complete Power Down
(mains and battery) to recover unit. If even recovery
fails the unit may be faulty
In very large installations or with more than one fog
units connected to the same alarm panel , a mains
power difference can occur , in that evenience the
units have to be decoupled
Error in the thermal loop
Error on thermocouple, resistor. Please refer to
technical service
All products are 100% tested
before shipping and a small
ammount of liquid could be
still in the warming unit
This condition is normal and can happen on first
installation, it will completely disappear in a while
when the unit will become completely hot.
Small fog flow coming out from
nozzle
RED Led ON (Error)
Too low battery level or exaust
Replace Battery
Bag in Reserve or Empty Replace fluid Bag
No Mains power
check mains power or F5 fuse
RED Led ON(Fault)
Heater Temperature too high or
thermocouple error
Switch off the unit and verify the screw on TC2
connector
Poor ventilation
Switch off the unit and clean air holes