Do not obstruct the nozzle when the generator is armed and bag is in.
The value in the first column indicates the volume of the room to be protected, with respective seconds of emission reported in the
second column. The value in m³ varies depending on the density to be obtained. With the suggested value it is possible to get the ma-
ximum density recommended to ensure the absence of any residual. In places where a little residual causes no problems, it is possible
to increase the shooting time. Please note that the more fog released, the more the time required to recover visibility. High levels of fog,
over recommended limits, can leave residual. Any residue usually goes away by itself within 24/48 hours, otherwise, being soluble in
water, it is enough to use a wet cloth for cleaning. If you desire to obtain an average of 1 meter visibility after 60 seconds, as specified
by the standard EN 50131-8 : 2019, as used as reference by all manufacturers of Fog generators, the number of shooting seconds it
is to be reduced in half.
SHOOTING TABLE MODULAR 4 PLUS (max 46 sec.)
SHOOTING TABLE MODULAR 5 PLUS (max 48 sec.)
SHOOTING TABLE MODULAR 8 PLUS (max 69 sec.)
m³ to protect
Seconds of emission
m³ to protect
Seconds of emission
m³ to protect
Seconds of emission
50 (150*) 6 150 (450*) 21 300 (900*)
40
75 (225*) 9
200 (600*) 23 400 (1200*) 46
100 (300*) 12 250 (750*) 35
m³ to protect
Seconds of emission
m³ to protect
Seconds of emission
m³ to protect
Seconds of emission
50 (150*) 6 150 (450*) 16 300 (900*)
27
75 (225*) 9
200 (600) 21 400 (1200*) 37
100 (300*) 12 250 (750*) 24 500 (1500*) 48
m³ to protect
Seconds of emission
m³ to protect
Seconds of emission
m³ to protect
Seconds of emission
50 (150*) 5 200 (600*) 19 500 (1500*) 43
75 (225*)
8
250 (750*) 22 600 (1800*) 51
100 (300*) 10 300 (900*) 26 700 (2100*) 60
150 (450*)
14 400 (1200*) 35 800 (2400*) 69
*
Industrial standard as from other manufacturers
SHOOTING TABLE MODULAR 2 PLUS (max 28 sec.)
m³ to protect
Seconds of emission
m³ to protect
Seconds of emission
m³ to protect
Seconds of emission
50 (150*)
7 100 (300*) 14 200 (600*)
28
75 (225*)
9
150 (450*) 21
SHOOTING TABLE MODULAR 3 PLUS (max 40 sec.)
m³ to protect
Seconds of emission
m³ to protect
Seconds of emission
m³ to protect
Seconds of emission
50 (150*) 7 150 (450*) 21 300 (900*)
40
75 (225*)
9
200 (600*) 28
100 (300*) 14 250 (750*) 35
RECOMMENDED SHOOTING SECONDS ACCORDING TO THE VOLUME SPACE TO PROTECT (m
3
)
Fogging systems Modular CPlus are able to produce fog continuously till the maximum time allowed , according to the model
specifications. There might be cases in which, due to specific characteristic of the location, levels of air temperature and pressure,
degree of the fog density and light in the target area, that the shooting time can be increased or decreased. For example, above
5 m of height the shooting time must be 20% more and above 7 m , every additional meter should be consideredas double.
(HxLxP) x D x V x R x I
HxLxP--------Height x Width x Depth of the area to protect
D-------------Density of the produced fog
V-------------Temperature and air pressure
R-------------Acceptable residue in case of saturation of V parameter
I--------------Intensity of the surface light
The following tables indicate the suggested fog emission in relation to the number of seconds of shooting set in average condition of
temperature, air pressure and humidity.
9
SHOOTING TIME SETTING
To set the shooting time, after removing the plastic front cover , in the middle of PCB is located the FIRETIME (S2) button.Holding down
the button , the 3 coloured front leds will flash and a sound is signal is executed by the buzzer , each flash/beep is equivalent to one
second of fog emission of the device.
Pressing the button again, the shooting time is not added to the one previously set, but will restart from zero.
If the button is pressed for a time higher of the unit capabilities , the fog emission will be set to the maximum allowed for the unit.
N.B. Before opening the cover ensure that the control panel is set to “service”, so that the opening of “anti-sabotage or
tamper” circuit does not cause any shooting.
N.B. Shooting time can be set according to whished seconds, but to correclty activate the bag reserve in full security, it
must be set to a minimun 4 seconds of shooting.
N.B.
To correctly dimension the machines it is needed to verify that the saturation of the area occurs in faster time than the one
supposed for the theft.