Specification and dimensions  

 

 

Standard technical specification 
 

Pump type............................Betsy 125H 
Max. flow..............................385 m3/hour  
Max. head............................32 mwc  
Dimensions L x W x H ......... 2612 x 1040 x 1756 mm 
Dry weight…………………..1900 kg 
Fuel tank .............................. 300 ltr  
Solids handling ....................100 mm  
 

Engine 

Engine brand ....................... Deutz 
Engine type .......................... F3L 
Flywheel power .................... 23.8 kW (32 Hp) 
Max. engine speed .............. 1800 RPM 
Fuel consumption ................ 4 l/h  
Displacement ....................... 2.2 l 
Number of cylinders ............. 4 
Cooling system .................... Water cooled 
 

 

 

 

Содержание Betsy 125H

Страница 1: ...www uprent eu P U M P I N G A N D E N E R G Y S O LU T I O N S PUMP USER MANUAL...

Страница 2: ...ead 32 mwc see curve Maximal suction lift 8 5m Suction connection 6 Discharge connection 6 Free passage Up to 100mm Dimensions L x W x H 2612mm x 1040mm x 1756mm Weight 1900kg Engine Diesel engine Eng...

Страница 3: ......

Страница 4: ...1 User manual Betsy 125H...

Страница 5: ...p unit 10 5 1 Moving the pump unit with a forklift 11 6 Pump unit installation 12 6 1 Outdoor use 13 6 2 Indoor use 14 7 Daily maintenance of the pump 15 7 2 Priming the fuel system 16 7 3 Engine oil...

Страница 6: ...of 8 to 9 meters or a suction length of 70 to 100 meters All pumps are supplied in a sound attenuated version These pumps are ideal for moving sewage water and dirty liquids containing large solids T...

Страница 7: ...control box 17 Suction side 18 Check valve 1 3 Intended use Pump are suitable for use in the following sectors contracting rental industry shipping waste water environmental protection water boards ir...

Страница 8: ...ot permitted to deploy a standard pump or pump unit in an ATEX environment Use the pump only for those applications listed on the pump specification sheet It is not permitted to use the pump for any a...

Страница 9: ...Max head 32 mwc Dimensions L x W x H 2612 x 1040 x 1756 mm Dry weight 1900 kg Fuel tank 300 ltr Solids handling 100 mm Engine Engine brand Deutz Engine type F3L Flywheel power 23 8 kW 32 Hp Max engine...

Страница 10: ...7 3 Performance curve...

Страница 11: ...and maintained by persons who have received appropriate training and are aware of the associated dangers The installer operator and maintenance personnel must comply with the local safety regulations...

Страница 12: ...ting oil B Diesel is hazardous to the environment with substantial remediation costs if it leaks into a drain waterway or the ground C Caution hot surface D Caution crushing danger E Oil F Hazardous o...

Страница 13: ...lifting eye on the engine nor the lifting eye of the bare shaft pump may be used for transport of the pump unit WARNING Lifting forces must be as vertical as possible the maximum lifting angle is 15 P...

Страница 14: ...d into these pockets to lift the pump unit WARNING Use certified lifting equipment with an adequate lifting capacity and always lift from directly above Lifting from an angle can lead to dangerous sit...

Страница 15: ...l Such use results in forfeiture of the right to assert any warranty or damage compensation claims Place the pump unit on a flat surface capable of supporting the load Make sure the pump unit is place...

Страница 16: ...can be fitted with safeguards for the following parameters temperature overpressure under pressure direction of rotation oil level overload 6 1 Outdoor use The pump unit is suitable for outdoor use In...

Страница 17: ...e area has adequate ventilation Make sure the exhaust gases are discharged outdoors Ensure that there is sufficient free space around the air intake so the engine is able to draw as much air as it nee...

Страница 18: ...e glass in the sidewall of the oil reservoir 2 and add if necessary 3 Check the oil level of the engine and add if necessary 3 4 Check the level of the fuel in the fuel tank and add if necessary 5 Che...

Страница 19: ...system Prime the fuel system before starting the engine for the first time after the fuel tank has been drained completely or after replacement of the fuel filter s 1 Open the bleeder screw 1 2 Squeez...

Страница 20: ...enance engine must be stopped 1 The engine must be in horizontal position before adding oil or checking the oil level 2 Pull out dipstick 4 and add engine oil of the correct specification and viscosit...

Страница 21: ...tches 1 2 3 Cable with red marking 1 is Maximum level cable with blue marking is Minimum level but cable in green marking 3 is grounding Installing sensors important is sensor 3 is always under water...

Страница 22: ...tic operation 6 Rood red electrode pin position High 7 Blue blue electrode pin position Low 8 Yellow green green and yellow earth electrode pin position Bottom 9 Electrode level socket Note The hour c...

Страница 23: ...2 Check the oil levels of the vacuum pump 3 Check the oil level of the engine add if necessary 4 Check the level of the fuel in the fuel tank and add if necessary 5 Check the state and tension of the...

Страница 24: ...mp unit Make sure the pump unit can draw adequate fresh air 3 Check whether the prescribed safety provisions are in place 4 Connect the hoses 5 Perform daily maintenance 6 Make sure there is sufficien...

Страница 25: ...22 11 Turn the switch 3 H 0 A in the position HAND 12 Turn the throttle 4 to maximum speed 13 Turn the switch 5 to position 1 Engine will start...

Страница 26: ...n WARNING If the pump vacuum lift is set too high cavitation in the pump set is possible and this can be recognized by High levels of vibration a crackling noise in the pump decreased capacity and pre...

Страница 27: ...ump unit can draw adequate fresh air 3 Check whether the prescribed safety provisions are in place 4 Connect the hoses 5 Perform daily maintenance 6 Make sure there is sufficient fuel in the fuel tank...

Страница 28: ...25 12 Turn the switch 3 H 0 A in the position AUTOM 13 Plug automatic level control socket 4 set the minimum an maximum electrodes 14 Turn the throttle 5 to maximum speed...

Страница 29: ...a crackling noise in the pump decreased capacity and pressure If this condition is allowed to persist for long periods it will cause damage the pump set Continued running of the pump set in this condi...

Страница 30: ...stop 3 Observe whether the system comes to a gradual smooth stop 4 When you suspect that the liquid is beginning to freeze drain the pump while the medium is still in the liquid state 5 Switch off ear...

Страница 31: ...g ports covers plugs 1 2 Make sure the canopy draining ports covers plugs 1 are not clogged with solids clean them if clogged 3 Open valves 2 make sure they are not clogged clean it if clogged and dra...

Страница 32: ...ient tension on divisible belt vacuum pump Check the tension of the divisible belt vacuum pump Tighten divisible belt with tensioning slide rails vacuum pump Opened drain tap in bottom pump house or f...

Страница 33: ...ssible Otherwise use a different type of pump The liquid has a higher s g or viscosity than that for which the pump is intended Change temperature of liquid if possible Otherwise use a different type...