26
15. Turn the switch (6) to position 1. Engine will start if all electrodes are under water.
16. Regulate engine speed with throttle (4), to necessary speed
WARNING
If the pump vacuum lift is set too high, cavitation in the pump set is possible and this can be
recognized by High levels of vibration, a crackling noise in the pump, decreased capacity
and pressure. If this condition is allowed to persist for long periods it will cause damage the
pump set. Continued running of the pump set in this condition will invalidate the warranty
DANGER
When float switches are used the pump unit may start automatically. Therefore
always switch off the power when working on the pump unit
WARNING
If vibration occurs during starting, stop the pump immediately and eliminate the cause
before starting again.