4G PRIMARY CELLULAR
ALARM COMMUNICATOR
®
4530EX
11
12
TECHNICAL SUPPORT
Technical support is available
Monday through Friday, 8:00 AM to 8:00 PM ET
excluding
holidays. Before calling technical support please ensure you have read the
installation guide completely. Technical support requires the caller to provide:
• Login name
• Password
• Serial number of the 4530EX
Uplink Security, LLC.
3330 Cumberland Blvd.
Suite 700
Atlanta, GA 30339
888-9-Uplink (888-987-5465)
www.uplink.com
INSTALLATION
A. General Considerations
Determine where to mount the unit. Keep the following in mind:
a. Where to obtain the best transmitted and received signal strength for the
cellular radio. (If the installer does not have a very strong cellular signal
in his area, he may want to first power the unit from a portable 12V DC
source, switch on S4 and move the unit to a location that gives him the
best signal strength.)
b. Proximity to the alarm panel and where to route the 4530EX’s relay output
that connects to an alarm panel input.
B. DIP Switch Settings
The 4530EX has a four-position dipswitch. The dipswitches function as follows:
SWITCH NO.
SETTING FUNCTION
S1: Default Load
OFF
Normal Operations
ON
Load Defaults
S2: OTA Operation
OFF
OTA configuration allowed
ON
OTA configuration blocked
S3: Reserved
OFF
N/A
ON
N/A
S4: LED Function
OFF
Normal Operations
ON
RSSI Measurements
(INSTALLATION continued next page)