4G PRIMARY CELLULAR
ALARM COMMUNICATOR
®
4530EX
25
26
SPECIFICATIONS
DIGITAL DIALER INTERFACE
Format Compatibility
Contact ID, SIA, Modem IIe/IIIa/IIIa
2
, Pulse
4/2 (:10, :20, or :40 PPS)
Connector
RJ45 and screw terminals
Simulated telco line voltage
48 V DC On-Hook
Dial tone
350 + 440 Hz +/- 0.2%
Receive level minimum
- 45 dBm, 20 dBm S/N
Line impedance
600 ohms
Ringer Equivalence
0.3 REN
Mode
Loop start. 26 mA typical
POWER REQUIREMENTS
Input Voltage
12V DC
Normal Current (On Hook)
125 mA
Maximum Current (Off Hook)
600 mA
Radio during Transmission
- Average Current
- Peak Current
215 - 250 mA
1.3 – 1.5 A
UL Power Requirements
Uninterruptable Class 2 power supply
12V DC/1.2 A
SPECIFICATIONS (cont.)
RADIO
Frequencies
850/1900 MHz
Sensitivity
-106 dB (typical)
ENVIRONMENTAL
Temperature Range
-30° to +70° C
Humidity
0 to 95% non-condensing
PHYSICAL
Height
2.5 inches
Width
5.4 inches
Depth
10.5 inches