4G CELLULAR
ALARM COMMUNICATOR
UL COMPLIANCE SECTION
PART 1– INSTALLATION
REQUIREMENTS (cont.)
Activation of this zone must annunciate locally at the keypad which shall
be programmed to display the message “For trouble see panel” or similar.
Furthermore, the Loss of Cellular Service must be programmed, via the website,
to annunciate locally within 2 minutes.
13. The Model 4550-CF Output Relay #2 must be programmed for Failure to
Receive ACK from the Central Station (i.e., Communications Failure), must be
connected to a reporting zone on the alarm panel, and the zone must be set
up as closed in the normal state and open in the off-normal state. Activation of
this zone must annunciate locally.
14. If the antenna which protrudes through the Model 4550-CF’s enclosure is
used, then the area where the unit is installed must be protected by a motion
detector which is wired back to Input No. 2 on the Model 4550-CF terminal
strip. This input must be programmed as an instant activation, 24 hour
reporting zone.
15. All connections to the base terminal block must be made with insulated
stranded copper wires using the wire gauge and length recommendations
below:
Recommended Wire Size
Maximum Length
18 gauge
20 ft
16 gauge
40 ft
14 gauge
60 ft
16. All connections to the UL battery must be made with stranded copper
insulated wires using the wire gauge and length recommendations in the
proceeding instruction. Additionally, connections to the battery shall be made
with insulated terminal connectors with a current rating of 2A or greater.