23
®
4550-CF
INSTALLATION (cont.)
7. Connect the wires from the 120 to 16.5 VAC, 45VA transformer to the
terminal strip positions designated as “AC” on the unit’s terminal strip.
Plug the transformer into a 120 VAC non-switched outlet. Use 18 to 14
gauge insulated copper wire for wire lengths of 10 to 25 feet respectively.
See the UL compliance sections for additional details.
8. Double check to make sure that the RSSI is still showing a good signal
strength level.
9. Before connecting the alarm panel and the 4550-CF, first:
a. Return Dipswitch #4 (S4) to the OFF position.
b. Disconnect the AC transformer from its power outlet.
c. Disconnect the Positive and Negative connections to the battery.
(INSTALLATION continued next page)
CAUTION: Incorrect Connections May result in Damage to the Unit