© UPLIFT Desk
• 800-349-3839 • 512-614-3152 • [email protected] • upliftdesk.com
5
KEYPAD LOCK
The keypad can be locked to prevent accidental activation or movement of the unit.
To lock:
Press and hold “M” button until display changes to “LOC”
To unlock:
Press and hold “M” button until display changes to numeric height setting.
NOTE:
If a power outage occurs, the program will automatically return to the unlocked setting.
MEMORY SETTINGS
Save up to two commonly used heights and recall them quickly.
l. Press the UP or DOWN button to move the unit to the desired height.
2. Press the “M” button.
3. Press the “1 or 2” button to assign the current height to a number on the keypad.
4. To recall any of those heights, press the numbered button to bring unit to assigned height.
HEIGHT CALIBRATION
Make sure the numeric display matches the actual height of the worksurface at its lowest position.
1. Press the DOWN button until the desk reaches the lowest position.
2. Measure the height from the floor to the underside of the worksurface. If the displayed height
does not match your measurement, follow the next steps.
3. Press the DOWN button until display flashes “RST”.
4. Press the “M” button until the numeric display begins flashing.
5. Press the UP or DOWN button to set unit to the measured height.
6. Once display changes back to “RST”, press the DOWN button until the unit lowers slightly, then
rises slightly and the display changes back to the numeric height setting.
*Note:
“RST” will look like
“ASr” on the display
CONSTANT-TOUCH & ONE-TOUCH
These steps allow the unit to be set to either One-Touch or Constant-Touch. One-Touch requires only
a single touch of the “1 or 2” button to move the unit to a preset memory location.
One-Touch is the
default setting.
Constant-Touch requires a continuous touch of the “1 or 2” button to move the unit to
a preset memory location.
Change between One-Touch and Constant-Touch:
l. Press the DOWN button until the unit reaches the lowest position.
2. Press the DOWN button again until display flashes “RST”.
3. Press the “1” button until display shows “10.1” (One-Touch) or “10.2” (Constant-Touch)
and goes back to “RST”.
Note:
While “RST” is still flashing, you can press the “1” button as many times as you’d like
to toggle between the two settings.
4. Press the DOWN button until the unit lowers slightly, then rises slightly and the display
changes back to the numeric height setting.
[x] POWER CABLE
[x] CONNECTING CABLE
(get from FRM200 instructions)
VESA screw
#10-24x1/2’’
Pan Head
M5x10
Pan Head
M6x10
Fla
t Head
Socket cap
These programming instructions are compatible only with
the Keypad that is included in this package.
PROGRAMMING (Memory keypad only)