Figure 4: Power and Connection board 

 

  Interphone module connector 
  Flat-cable interface connector to communication module 

 

Programmable relay output (100mA max. load) 

  Wired detector zone (Zone 33, 34) 

 

System bus terminal block (hardwire LCD keypad, Wired Zone Module) 

 

Flat-cable interface connector to Main board (LCD keypad, built-in speaker, 
microphone and siren) 

  Front tamper switch 

 

Interface connector to Home Automation module 

 

AC power terminal block 

  Home Automation module terminal block 
  AC power protection fuse 

  Backup battery connector 

 

Содержание iconnect

Страница 1: ...Quick Start Installation Guide For detailed information please refer to the full iConnect Installer Manual provided on our website www electronics line com ...

Страница 2: ... Wireless Allocation 8 4 4 1 Main unit calibration 8 4 4 2 Registering 2 way Wireless Devices 9 4 4 2 1 Detectors 9 4 4 2 2 Keyfobs 11 4 4 2 3 Wireless LCD keypads 12 4 4 2 4 Wireless Siren 13 4 4 3 Delete Wireless Device 13 4 5 Program Communication to Monitoring Station 15 4 6 Set Up Follow Me Destination 16 4 7 Set Time Date 17 4 8 Set Edit Users 18 4 9 GPRS Settings 20 4 10 Connect to ELAS GPR...

Страница 3: ... the back cover and connect the cable to the AC power input on the main board Caution Do not apply AC power at this stage 5 If required connect a network IP cable and or insert a SIM card to the GSM GPRS module 6 Connect the battery pack to the connector If an alarm occurs insert the master user code number default 1234 to silence the alarm 7 Mount the control system to a wall 8 Close the front co...

Страница 4: ...4 3 System Layout 3 1 System Architecture Figure 1 shows the components of the system and the systems interaction with external communication networks Figure 1 System Architecture See Figure 2 ...

Страница 5: ...5 Figure 2 Main board Contrast LCD Speaker Bell Jumper for siren volume Flat Cable ...

Страница 6: ... an additional designed option to be installed inside the plastic housing Figure 3 System layout Power and Connection board Communication module GPRS GSM LAN Backup battery pack 3 2 1 Power and Connection Board The Power and Connection board is the system s main part and connects to various peripheral modules using a number of interface connectors as seen in Figure 5 ...

Страница 7: ...ired detector zone Zone 33 34 System bus terminal block hardwire LCD keypad Wired Zone Module Flat cable interface connector to Main board LCD keypad built in speaker microphone and siren Front tamper switch Interface connector to Home Automation module AC power terminal block Home Automation module terminal block AC power protection fuse Backup battery connector ...

Страница 8: ...t installer code is 1111 3 Using the arrow keys select 9 Programming 4 3 Selecting a language The iConnect supports multiple languages For easy operation select your language as follows 1 Go to the main menu select 9 7 1 Programming Initialize Init All 2 Select default and press Select language Voice LCD display and press 4 4 Wireless Allocation 4 4 1 Main unit calibration The first step in wirele...

Страница 9: ... it must be followed by the deletion of the panel in the detector If this is not done it will lead to an out of Sync situation by design Step 1 Register a detector 1 Go to the main menu select 9 1 1 Programming Devices Zones 2 Using the arrow keys select a specific zone and press The system initiates Registration mode 3 Send a transmission from the detector using the following method Open the dete...

Страница 10: ... 7 Force Arm Arm the system even if a zone is not ready For the force arm feature to function you must also enable force arming in system options Table 2 Parameter settings Note PIR and Camera PIR detector have dedicated parameters They can be defined using quick key 9 1 1 11 4 If required scroll thorough the other menu parameters and modify settings as warranted Step 3 Detectors Test 1 Go to the ...

Страница 11: ...s The iConnect Control System supports up to 19 keyfobs Step 1 Register a keyfob 1 Go to the main menu and select 9 1 2 Programming Devices Keyfobs 2 Select a specific keyfob using the arrow keys and press The system initiates Registration mode 3 Press a button on the keyfob making sure that the keyfob s green LED lights up when the button is pressed Note A red LED indicates a communication proble...

Страница 12: ...714 Refers to button Assign the desired HA unit for the button to control 01 16 or 30 31 for PGM output It is possible to enter 00 to program the button s default function Perimeter arming Table 5 Keyfob parameters Step 3 Testing the keyfobs 1 Go to the main display and press 2 Enter the Installer code default code 1111 3 Select 7 04 2 Service Transmitters TX Test to initiate TX communication Test...

Страница 13: ...he Control System s LCD display press 3 Continue and define the siren parameters WL siren delay time interval the wireless siren is not heard This occurs as soon as an alarm is triggered Siren cut of time Duration of the siren after an alarm has occurred Wired siren Main unit internal siren Enable Disable the build in siren in on the main unit during alarm Step 2 Test the siren 1 Go to the main di...

Страница 14: ...il the red led stops flashing 2 Press for two seconds until the red led stops flashing Wireless keypad Installer menu quick key 9 1 3 Select keypad 3 1 Take out the keypad battery 2 While the back tamper switch is being pressed insert the batteries 3 Within five seconds open the tamper and close it once again LCD Wireless Siren Installer menu quick key 9 1 5 5 1 Take out the siren battery 2 While ...

Страница 15: ...S select GPRS or LAN Accounts 2 6 GSM 9 5 1 4 Two Way Audio Enable Disable two way audio verification conversation between the premises and the operator at the MS 9 5 1 5 Account number Insert up to eight digits Enter leading zeros for account numbers of less than eight digits Use the key to enter hexadecimal digits If the programmed protocol is Contact ID A is not a valid entry in the account num...

Страница 16: ...be used with the Follow me feature It is the only telephone number that can be programmed by the user in the following location only if defined as SMS or TWA Main menu 5 Telephone 1 Follow Me Number 4 Insert the Follow Me telephone number and press 5 Select the protocol from the following options Two Way Audio Follow Me SMS Follow Me Voice Report 6 Define the communication interface for the Follow...

Страница 17: ...sert installer code default code 1111 3 Select 7 01 Service Set Time Date 4 Select 1 Set Time Enter the current time and press 5 The display shows 2 Set Date option Enter the current date and press Notes 1 If the time is set to 12hr format use the key to toggle between AM and PM 2 If the system is connected to the ELAS system the time and date will be automatically updated ...

Страница 18: ...g the control system notifies the central station with an Arm Disarm event message 20 25 Non controlled Codes Non controlled codes do not cause the system to send Arm Disarm event messages to the central station 26 27 Limited Codes Controlled codes valid for 24 hours 28 Duress Code Designed for situations where the user is being forced to operate the system 29 Telecontrol Code Designed to enable t...

Страница 19: ... and press 5 The display shows 1 Edit Code Press 6 Type the new code and press to confirm 7 Scroll to 2 Descriptor option and press 8 Type user name and press to confirm 9 Press X and select another user 10 Repeat stages 4 9 to set the code for additional users Note To delete the code enter 0000 The installer and master codes cannot be deleted ...

Страница 20: ...code is used it should be programmed in the control system before inserting the SIM card in the GSM module 2 Edit the APN Access Point Name of your GPRS connection a Go to the main menu and press b Insert installer code default code 1111 c Select 9 5 7 6 1 Programming Communications Internet GPRS Options APN d Enter the APN name provided by the cellular provider e Press as soon as editing procedur...

Страница 21: ...s password 1 Go to the main display and press 2 Insert installer code 3 Select 9 5 7 4 Programming Communications Internet CP Password 4 Insert a password using the alphanumeric keypad The password length may be up to 16 characters The password must begin with a letter 5 Press If the Control System is unable to connect to ELAS an error message is displayed Table 9 indicates the optional error mess...

Страница 22: ... 160 x 120 Color Define whether the pictures will be colored or black and white Compression Used to compress and resize the image file High compression reduces the file size Flash Define if the flash is disable or automatic enabled PIC Alarm Number of pictures in alarm 1 9 Pictures Delay Delay between pictures 100ms 500ms User monitoring Defines the permission to perform snapshots from the ELAS Zo...

Страница 23: ...ransmitter list The TX list displays the zone device number or descriptor press the key to toggle the display the signal strength of the last received transmission and the last received status of the transmitter 7 0 6 GSM Signal Strength Display the signal strength of the cellular network In severe cases of low GSM signal consider using external GSM antenna 7 0 4 4 RF RSSI level Measure the RF RSS...

Страница 24: ...robbery fire or otherwise or that the product will in all cases provide adequate warning or protection Buyer understands that a properly installed and maintained alarm may only reduce the risk of intruder robbery or fire without warning but is not insurance or a guaranty that such will not occur or that there will be no personal injury or property loss as a result Consequently seller shall have no...