ABSENCE OF ELECTRICAL SUPPLY
In case of absence of electrical supply during a cooking program, the oven can resume and take to the end
the afore mentioned cooking program if the electrical supply is restored within a time limit of 5 minutes from
the interruption. After these 5 minutes the oven will interrupt the cooking program (also not recoverable after
a time that long) and will show the corresponding error message (see ALARM CODES)
SOFTWARE UPGRADE
Both the electronic tools (80P and Vision Full Touch) can be on site updated with the last release of the
available software after authorisation by the producing company.
In case of malfunctions due to software issues, contact our assistance service and verify with the
professional any possible software update available.
ALARM CODES:
The error messages provided by the electronic control in case of operating anomalies are
listed below. When one of the following errors is displayed, except for error 009 which
is self-resetting, you must contact your nearest customer service center.
Er. 001
= the power board gives no feedback
Er. 002
= wrong firm-ware
Er. 003
= probe alarm: a probe is disconnected or short-circuited
Er. 004
= heating element anomaly
Er. 005
= program memory not working
Er. 006
= program for delayed start removed after setting
Er. 007
= blackout error: the baking could not resume after a blackout
Er. 008
= no network synchronism: the frequency of the network is unstable, or the power board is faulty.
Er. 009
= motor thermal protection: the power board has blocked the oven because of excessive
heating of the motor. Once the anomaly is resolved, the oven returns operational
Er. 010
= auxiliary board 1, if present, does not answer
Er. 011
= auxiliary board 2, if present, does not answer
Er. 012
= auxiliary board 3, if present, does not answer
Er. 013
= auxiliary board 4, if present, does not answer
Er. 015
= the vacuum-sealed probe has been connected or disconnected during the cooking
program
Er. 016
= communication problem between display board and power board
Er. 017
= communication problem between display board and keyboard
In the presence of one or more errors, before proceeding to ask for assistance, it is recommended to shut
the electrical supply of the oven down for at least 2 minutes. Verify the presence of the irregularity once the
oven is turned on again and, if persistent, contact the assistance service specifying the corresponding error
code.
RDRG
Содержание RDR-GAS
Страница 1: ...RDR GAS ROTATING DOUBLE RACK BAKERY OVEN ...
Страница 8: ...Page 8 VIEW OF THE EQUIPMENTS VOLUMES AND CONNECTIONS OF GAS VERSION OF UNIT RDRG ...
Страница 40: ...Page 40 ELECTRIC DIAGRAM ...
Страница 41: ...Page 41 ...
Страница 42: ...Page 42 ...
Страница 43: ...Page 43 ...
Страница 47: ...Page 47 Phone 603 458 7690 Address P O Box 1062 Windham NH 03079 ...