background image

NEVER use an open flame of any kind to test this unit. You might accidentally
damage or set fire to the unit or to your home. The built-in test switch accurately
tests the unit's operation as required by Underwriters Laboratories Inc. (UL).

If you choose to use an aerosol smoke product to test the smoke alarm, be
certain to use one that has been Listed to Underwriters Laboratories, Inc. Safety
Standards and use it only as directed. Use of non-UL Listed products or improper
use of UL Listed products may affect the smoke alarm's sensitivity.

MAINTENANCE:

 The smoke alarm is virtually maintenance free. However, under

dusty conditions, a vacuum hose may be used to clear the sensing chamber of dust.

BATTERY REPLACEMENT

The smoke alarm uses a 9 Volt carbon-zinc battery. The battery should last for at
least one year under normal operating conditions. The smoke alarm has a low battery
indicator, an audible "beep." It will operate at 30-40 second intervals for a minimum of
7 days. When this indication occurs, replace the battery with an Alkaline type (Eveready
Energizer #522, Duracell #MN1604), Carbon-Zinc type (Gold Peak #1604P, Eveready
#216).

REPAIRS AND SERVICES

If the smoke alarm is defective in any way, do not tamper with the unit. Return the unit
for servicing. (See warranty for instructions or in-warranty returns.) There will be a
service charge for repairing out of warranty units.

Page 4

Содержание SS-901

Страница 1: ...nd properties SMOKE ALARMS CANNOT WORK WITHOUT POWER Battery operated units cannot work if the batteries are missing disconnected or dead if the wrong type of batteries are used or if the batteries are not installed correctly AC only powered units cannot work if the AC power is cut off for any reason If you are concerned about the limitations of battery or AC power install both types of units SMOK...

Страница 2: ... mounting on an inside partition is preferred to avoid the thermal barrier that may form at the ceiling When mounting smoke alarm on the ceiling locate it a minimum of 4 10cm from a side wall or corner see Diagram A When mounting smoke alarm on a wall if local codes allow use an inside wall with the top edge of the smoke alarm a minimum of 4 10cm and a maximum of 12 30 5cm below the ceiling wall i...

Страница 3: ...ge products of combustion are present when you start your automobile near appliances or areas where normal combustion regularly occurs kitchens near furnaces gas hot water heaters Use smoke alarms with Silence Control for these areas in areas with high humidity like bathrooms or areas near dishwashers or washing machines Install at least 3 feet 0 9 meters away from these areas in areas of turbulen...

Страница 4: ...nance free However under dusty conditions a vacuum hose may be used to clear the sensing chamber of dust BATTERY REPLACEMENT The smoke alarm uses a 9 Volt carbon zinc battery The battery should last for at least one year under normal operating conditions The smoke alarm has a low battery indicator an audible beep It will operate at 30 40 second intervals for a minimum of 7 days When this indicatio...

Страница 5: ...is all right to do so NATIONAL FIRE PROTECTION ASSOCIATION REQUIRED PROTECTION For your information the National Fire Protection Association s Standard 72 reads as follows 11 5 1 One and Two Family Dwelling Units 11 5 1 1 Smoke Detection Where required by applicable laws codes or standards for the specified occupancy approved single and multiple station smoke alarms shall be installed as follows 1...

Страница 6: ...land 21117 postage prepaid with a payment of 4 00 to cover the costs of return postage and handling You must include a proof of purchase receipt along with the returned product UNIVERSALDOESNOTWARRANTANDSPECIFICALLYDISCLAIMSANY WARRANTY WHETHER EXPRESS OR IMPLIED OF FITNESS FOR A PARTICULAR PURPOSE OTHER THAN THE WARRANTY CONTAINED HEREIN NOIMPLIEDWARRANTYONTHISPRODUCT CREATEDBYSTATE LAW SHALLEXTE...

Отзывы: