42
print the results of the latest measurement ( irrespective of unbalance value). Key „28” does not
reset printer automatic operation mode.
If printing is not required switch printer power supply will switch on the back plate. It is
recommended to switch the printer off prior to switching balancing machine power supply off.
15 . NOTES ON OPERATION
Weight should be finally hammered to the wheel rim edge after the whell has been balanced
and removed from balancing machine fixture.
In the case of major unbalance in one plane - e.g. 90g and a minor one in another plane - e.g.
10g, we recommended to fix a 90g weight only and to repeat the measurement as it may happen
that after balancing the „worse” plane the unbalance value of the other plane will drop below
10g value, measured previously.
If the unbalance is more than 100g fix a large weight (e.g. 80g, 90g, 1000g) and shift it several
centimetres from the point indicated by the balancing machine. Then repeat measurement
and fixc additional small weights of masses indicated by the balancing machine.Then repeat
1 6 . W A R R A N T Y
All repairs (if any) and adjustments are performed by the manufacturer. Repairs carried out
by the buyer will entail loos of warranty.