background image

KERBEROS POWER

6

3. POWER MODULES

1. Each power module has its display to provide the user with information 
about its current status. When the input voltage is connected, 4 green LEDs 
blink, indicating that the module is OK and waiting for communication with 
the control board to check if the panels are able to deliver some min. power 
(tested at approx. 3W), which lasts for at least 10 to 20 minutes; in case of 
insufficient insolation, the modules do not reach the standby mode (1 green 
LED flashes). After a successful test of communication with the control 
module, the first green LED flashes and indicates that the module is ready to 
deliver power to the load. When the module is active and delivers power to 
the connected load, it displays the value of the power with the permanent 
light of the respective LEDs. E.g. when the power is below 400W, the first 
green LED is lit, the power from 400 to 800W illuminates 2 green LEDs, etc. 
The module fault is signalled by permanent red LED marked Err.

Actual

output

of module

EN