2. CONTROL MODULE

Temperature

of water

Device

status

Setting

button

Button

on/off

Communication

connector

SET mode: When pressing the SET key and holding for more than 3 seconds, 
the line titled Temperature blinks, repeated pressing SET increases the set 
temperature. After reaching the maximum temperature value and further 
pressing SET the cycle jumps again to the minimal temperature. To save the 
set temperature, hold down SET for 3 seconds again. After that the actual 
temperature in the tank is being displayed . 

1. The temperature is displayed and set in five discrete steps. 

Display mode: The LED line titled Temperatures displays actual temperature 
of water in the tank. The temperature is displayed in discrete values, at 
temperatures up to 40°C inclusive 1 LED is lit, at a temperature in the range of 
41 to 50 ° C inclusive 2 LEDs are lit, etc.

2. LEDs called Status indicate whether LED Heating, thermostat sensor faults 
and temperature fuse are active. If there is a fault on the temperature fuse 
sensor or the fuse is activated, the Fuse Err LED is lit. If the thermostat 
temperature sensor fails, the LED Temp Err lights up. If an EEPROM error 
occurs, General Err LED is on.

3. For turning the heating On / Off use the On / Off button. When the heating 
is on, the On / Off button is backlit.