18
Classic P3 x/x - 15-40A
Displays
Some important functions are indicated by LEDs:
Display
LED
Drive ready
BTB
Current controller enable
enable
Triggering enabled
enable triggering
Current command value direction
RVI
The green LEDs indicate the active states!
BTB signal - Drive ready
BTB signal
X3:25
>+10V
Error
X3:25
<+2V
Error
Auxiliary voltage supply
+24V, +15V, -15V
Power supply:
Fuse failure
Under-voltage
In case of errors or failure the power section is internally disabled without delay.
Measurements
Measurement advice
Measuring instruments:
multimeters for current
and voltage
shunt or clamp-on ammeter
Measuring faults:
mean value > actual value
acc. to the form factor
approx. 1 to 5%
Measured values
with a positive command value
Voltage:
X10:10 negative, X10:13 positive
max. 1.15 x power supply
Current:
ammeter in the motor circuit
Measured values across REG4
Speed
X2:109
±5V for ±100% speed
Current
X2:111
±5V for ±200% current
GND
X2:104
D
is
p
la
y
s
BT
B
R
VI
En
a
b
le
En
a
b
le
ig
n
it
io
n