16
Classic P3 x/x - 15-40
A
ct
u
a
l
v
a
lu
e
co
n
n
e
ct
io
n
Actual value connection
Tacho
Suitable actual value encoders:
- DC tacho generator
- Brushless tacho generator with evaluation electronics
- Incremental encoders with evaluation electronics
- AC or three-phase tacho with rectification
Connection
Control electronics (see Manual REG)
In case of a positive command value
Tacho positive
X 1:8b
Tacho negative
X 1:9
Shield
X 1:8
Armature voltage
Ground referenced actual value
Fuses
2x 0.1A/500V
directly in the armature circuit
For armature voltage
>180V=
additional resistors are required
Use unit UNITEK EXZU-UA1
(including 2 fuses and 2 resistors in an insulated housing)
REGxx
* only for
Содержание Classic P3 400/450-15
Страница 1: ...MANUAL Classic P3 1 Quadrant Thyristor Drive 15 to 40 A P3 15 40A Edition 0308 1...
Страница 8: ...8 Classic P3 x x 15 40A Dimensions P3 15 25A Enable Enable ignition...
Страница 9: ...P3 15 40 9 2 Mechanical Installation Dimensions P3 40A Enable Enable ignition...
Страница 24: ...24 Classic P3 x x 15 40A Connection Diagram...