12
Classic P3 x/x - 15-40
Direct power connection
Connection
Phase
L1
terminal X10:16
Phase
L2 (N)
terminal X10:15
Phase
L3
terminal X10:14
Input fuses
Super fast acting fuses
Power choke
Inductance >200mH
Power connection with a transformer
Transformer performance
1.1 x continuous motor power
Secondary voltage
0.9 x motor power
Transformer fuses
Slow acting
Input fuses
Super fast acting fuses
Attention:
If the secondary voltages produced by the
transformer are inferior to 60% of the rated device
voltage, the voltage watchdog has to be adapted. These modifications may only
be effected in the factory and thus, the transformer secondary voltage has to be
indicated on order.
Internal watchdog for fuse failures
P
o
w
e
r
co
n
n
e
ct
io
n