P3 15-40
13
3 Elektrical Installation
Motor connection
Connection
Motor-
bolt X10:10
Motor+
bolt X10:13
Armature choke
Inductance:
-L 4[mH
]
= U/I
A
x 0.8
Armature chokes are only necessary for
special applications, e.g. low-noise motor
operation (stagecraft).
Switching in the armature circuit
- dc circuit current-free
- disable inactive
Warning
:
Faulty switching will create arcing across the switch contacts.
Power supply failure - brake resistor
Break contact of the mains contactor K1
in parallel to the motor armature
without separation from the device
Attention:
Power lines have to be shielded and routed separately from
control lines!
For electro-magnetic interferences please refer to the CE advice (page 15).
M
o
to
r
co
n
n
e
ct
io
n
X10: 10
13
Содержание Classic P3 400/450-15
Страница 1: ...MANUAL Classic P3 1 Quadrant Thyristor Drive 15 to 40 A P3 15 40A Edition 0308 1...
Страница 8: ...8 Classic P3 x x 15 40A Dimensions P3 15 25A Enable Enable ignition...
Страница 9: ...P3 15 40 9 2 Mechanical Installation Dimensions P3 40A Enable Enable ignition...
Страница 24: ...24 Classic P3 x x 15 40A Connection Diagram...
Страница 25: ...P3 15 40 25 8 Drawings Circuit diagram P3...