CHAPTER 4: USER MAINTENANCE
9100 SERIES REFLOW SOLDERING SYSTEM
4-2
990-606
Clean Vacuum Generator Filter
To change the vacuum generator filter, perform the
following steps:
1 Remove the two hoses connected to the vacuum
generator by carefully pulling them, with a twisting
motion, from the generator (figure 4-1).
2 Remove the two screws securing the generator to the
bottom of the workstation table.
3
Remove four screws from side of vacuum
generator to remove the filter assembly (figure 4-2).
4 Slide out filter assembly and remove filter (figure 4-3).
WARNING:
Wear safety glasses when working with air
under pressure.
5 Clean filter by blowing off dust particles with low-
pressure air.
6 Reassemble the vacuum generator and reinstall it by
reversing the above steps.
Grease Rotary Table Ring Gear and Refill Lubricators
To grease the ring gear and refill lubricators perform the following steps:
1 Remove any pneumatic hoses between any jig and the central wheel hub.
2 Remove all jigs to obtain access to the rotary table mounting screw. Each jig is held in place by four
cap screws.
REMOVE TWO
MOUNTING
SCREWS
PULL OUT
TWO HOSES
Figure 4-1. Removing Vacuum
Generator from Workstation
Figure 4-2. Removing Filter Assembly from
Vacuum Generator
REMOVE FOUR SOCKET
HEAD SCREWS TO
REMOVE FILTER
ASSEMBLY
Figure 4-3. Removing Filter
from Filter Assembly
SLIDE FILTER FROM
FILTER ASSEMBLY
Содержание 9100 Series
Страница 14: ......
Страница 25: ...9100 SERIES REFLOW SOLDERING SYSTEM 990 606 A 1 APPENDIX A SPECIFICATIONS...
Страница 32: ......