Page | 42
6.3 Premature System Halt
Possible Problem
Item to Check
Remarks
No power to the
machine
Verify that the Power
Indicator is lit
Follow the procedures under “Interface Not
Functioning”
Drive error or
overload
Check Drive Keypad for
error code.
Refer to the instruction manual for the drive that
was supplied with the machine or contact
UNITED SURFACE SOLUTIONS for support.
Human error
Attempting to open the
Shutter Door while the
machine is running may
result in the cycle being
canceled.
The Stop Button may have
been accidentally pressed.
If the cycle timer has reset, human error is likely
the problem. If the machine is stopped and the
timer is still running, human error must be
discounted.
E-Stop activated
Check the CPC Touch
Screen to determine if the
E-Stop has been activated.
If the E-Stop has been activated the timer will
display the remaining time. Proceed to Manual
Mode Screen to determine time remaining and
finish the current process.
Loose wire or
defective component
Turn the main disconnect
to the “Off” position and
carefully check and
retighten electrical
connections beginning at
the main disconnect.
If you are certified to work with high voltage AC,
re-energize the Disconnect and follow the
voltage paths until you find the problem.