Page | 19
The next step is to set the turret RPM and cycle time. To accomplish this, input the number from the
keypad and press ENTER. The arrow keys allow scrolling between RPM and time. Pressing CONTINUE
will display the separator and elevator controls. This is final screen of the interview.
4.4.2 Separator Controls
To control the parts/media separator and rinse systems, utilize the screen illustrated below in Figure
4.15. Through this screen, the separator speed and maximum run time can be set. The speed should
be adjusted so the parts and media flow evenly across the screen deck without bouncing. The run
time sets the amount of time the separator and elevator operate before automatically shutting down.
This time should be adjusted to allow the operator time to unload and load all four barrels and clear
the separator of any parts and media (approximately 10 to 20 minutes). Once the separator shuts
down, the elevator will continue to operate for 20 seconds to empty the buckets completely.
RPM
&
T
IME
F
IGURE
4.14