10
6. Using Your Alarm (non-digital version, 5CO)
Recognising Alarm Signals and Warnings
Feature
What this means
Required Ac1on
Green LED flashes every 30 seconds
Normal opera1on
None
The alarm chirps every 60 seconds and the red
LED flashes
Low ba2eries
Replace ba2eries as soon
as possible
Alarm chirps twice every 30 seconds and the
red LED flashes twice
End of life of the alarm
Replace the alarm
Alarm chirps every 30 seconds and red LED
flashes every 30 seconds
Fault
Replace the alarm
Red LED on and constant tone
Malfunc1on
Replace the alarm
Loud, con1nual alarm (4 beeps – 5 second
pause – 4 beeps...) and the red LED flashes
Dangerous levels of CO
have been detected
Follow emergency
procedures (see Page15)
2532-7202-10_5CO_ASH:_ 2018.10.26 5:43 PM Page 10