-15-

Daily

Weekly

Monthly or as needed

Burn Pot

Stirred

Empty

Combustion Chamber

Brushed

Ashes

Check

Empty

Interior Chambers

Vacuumed

Combustion Blower Blades

Vacuumed / Brushed

Convection Blower Impeller

Vacuumed / Brushed

Vent System

Cleaned

Gaskets

Inspected

Glass

Wiped Cleaned

Hopper (end of season)

Empty and vacuumed

When your stove acts out of the ordinary, the first reaction is to call for help. This guide may save time and money 

by enabling you to solve simple problems yourself. Problems encountered are often the result of only five factors: 

1) poor fuel; 2) poor operation or maintenance; 3) poor installation; 4) component failure; 5) factory defect. You 

can usually solve those problems related to 1 and 2. Your dealer can solve problems relating to 3, 4 and 5. Refer 

to diagrams on page 25 to help locate indicated parts.

For the sake of troubleshooting and using this guide to assist you, you should look at your heat level setting to see 

which light is flashing.

• 

Disconnect the power cord before performing any maintenance! NOTE: Turning the ON/OFF Switch to ”OFF” 

does not disconnect all power to the electrical components of the stove.

• 

Never try to repair or replace any part of the stove unless instructions for doing so are given in this manual. All 

other work should be done by a trained technician.

Display is Flashing “E1”
Possible Causes

Possible Remedies: (Unplug stove first when possible)

The convection blower is overheating and tripping the 

internal temperature shutoff.

Clean any dust off of the windings and fan blade. If 

oiling  the  blower  does  not  help,  the  blower  may  be 

bad.

The  stove  is  being  left  on  the  highest  setting  for 

extended periods of time.

If operating the heater on the highest heat setting, the 

room  temperature  could  increase  enough  and  lead 

to potential overheating situations. If this happens try 

operating at a lower heat setting.

Fuel  other  than  wood  pellets  is  being  burned  in  the 

stove.

This pellet stove is designed and tested to use wood 

pellets. Check for signs of fuel other than wood pellets. 

No  other  types  of  fuel  have  been  approved  for  this 

pellet  stove.  If  there  are  signs  of  other  types  of  fuel 

being used, stop using them immediately.

Power surge or brown out situation.

A power surge, spike, or voltage drop could cause the 

high limit switch to trip. Check to see if a surge protector 

is being used on the stove. If not, recommend one to 

the customer.

High Limit Switch is malfunctioning.

If the other items check out OK, replace the high limit 

switch.

ATTENTION: This wood heater needs periodic inspection and repair for proper operation. It is against federal 

regulations to operate this wood heater in a manner inconsistent with operating instructions in this manual.

Trouble Shooting Guide

MAINTENANCE SCHEDULE

Use  the  following  as  a  guide  under  average  use  conditions.  Gaskets  around  door  and  door  glass  should  be 

inspected and repaired or replaced when necessary.

Содержание VOGELZANG VG5501S

Страница 1: ...es during the installation of this appliance Contact your local building or fire officials about restrictions and installation inspection requirements in your area These Pellet Stove Room Heaters have...

Страница 2: ...ill not feed pellets under these circumstances and a safety concern may arise from sparks or fumes entering the room Allow the stove to cool before performing any maintenance or cleaning Ashes must be...

Страница 3: ...ome Your stove is Certified to ASTM E1509 12 2017 and Certified to ULC S627 00 This manual describes the installation and operation of the Vogelzang VG5501S wood heater This heater meets the 2020 U S...

Страница 4: ...tions CLEARANCES Your pellet stove has been tested and listed for installation in residential mobile home in accordance with the clearances given below For safety reasons please adhere to the installa...

Страница 5: ...tions PELLET VENT TYPE A certified 3 inch or 4 inch type PL pellet vent exhaust system must be used for installation and attached to the pipe connector provided on the back of the stove use a 3 inch t...

Страница 6: ...pipe should be added with a horizontal cap which would complete the installation A support bracket should be placed just below the termination cap or one every 4ft 1 22m to make the system more stabl...

Страница 7: ...ndatory for mobile home installation See Outside Air Supply section and your dealer for purchasing Check with your local building officials as other codes may apply 69FAK OUTSIDE AIR SUPPLY OPTIONAL U...

Страница 8: ...start in approximately 5 minutes The red light located above the POWER button will turn green when pressed and remain green until the stove is turned off After pushing POWER the auger motor is on for...

Страница 9: ...djuster to adjust the amount of fuel allowed to pass into the auger assembly The fuel adjuster is located inside the hopper Note To increase the flow of pellets move the fuel adjuster up To decrease t...

Страница 10: ...means of supporting the fuel Use only the burn pot supplied with this heater Hopper lid must be closed in order for the unit to feed pellets During the start up period 1 Make sure burn pot is free of...

Страница 11: ...ER WARNING This wood heater has a manufacturer set minimum low burn rate that must not be altered It is against federal regulations to alter this setting or otherwise operate this wood heater in a man...

Страница 12: ...exchanger The cleanouts are located inside the cabinet doors on the lower front corners of the heat exchanger To access these clean outs you must remove both side panels The clean outs are secured to...

Страница 13: ...eason the entire system be professionally inspected cleaned and if necessary repaired To clean the chimney disconnect the vent from the stove ASH REMOVAL Remove the ashes periodically to avoid unneces...

Страница 14: ...If glass is broken follow these removal procedures 1 Remove the four 4 screws and glass retainers 2 While wearing leather gloves or any other gloves suitable for handling broken glass carefully remov...

Страница 15: ...le Remedies Unplug stove first when possible The convection blower is overheating and tripping the internal temperature shutoff Clean any dust off of the windings and fan blade If oiling the blower do...

Страница 16: ...air switch Combustion blower failure With the stove on check to see if the combustion blower is running If it is not you will need to check for power going to the combustion blower It should be a full...

Страница 17: ...s that hold the auger bracket to the auger tube The auger bracket will now be able to be removed form the auger tube Remove the two bolts on the side of the auger tube to remove the lower bearing of t...

Страница 18: ...s Use a continuity tester to test the hopper safety switch replace if necessary The auger shaft is jammed Start by emptying the hopper Then remove the auger motor by removing the auger pin Remove the...

Страница 19: ...ible Causes Possible Remedies Unplug stove first when possible There is a leak in the vent pipe system Inspect all vent pipe connections Make sure they are sealed with RTV silicone that has a temperat...

Страница 20: ...Loose wire or connector Check all wires and connectors that connector to the auger motor high limit switch and the Molex connector Bad control board If the fuse is good the wires and connectors check...

Страница 21: ...pect the damper assembly Make sure the damper plate is attached to the damper rod When the damper rod is moved the plate should move with it Blockage in air intake pipe Visually inspect the air intake...

Страница 22: ...22 Parts Diagram...

Страница 23: ...t Covers 2 15 88258 Gasket Ash Clean out 2 16 80607 Igniter 1 17 83538 Shaft Collar Ignitor Tube 1 18 69762 Burnpot 1 19 80599 T Disc Exhaust 1 20 80529 Auger Motor 1 21 892665 Auger Motor Mounting Br...

Страница 24: ...24 Wiring Diagram 1 25A 250V FUSE 7 5A 250V FUSE CORRECT WRONG Ensure the wires are connected to the bottom two prongs of the hopper switch as shown...

Страница 25: ...25 Notes...

Страница 26: ...26...

Страница 27: ...rvice fiable et efficace de votre appareil de chauffage et vous permettre de commander correctement les pi ces de rechange Conservez ce manuel dans un endroit s r pour r f rence future Lors de l critu...

Страница 28: ...25...

Страница 29: ...24 Sch ma De C blage 1 25A 250V Fusible 7 5A 250V Fusible CORRECT FAUX Assurez vous que les fils sont connect s aux deux broches inf rieures de l interrupteur de la tr mie comme illustr...

Страница 30: ...oint de nettoyage des cendres 2 16 80607 Allumeur 1 17 83538 Collier d arbre tube d allumage 1 18 69762 Pot de combustion 1 19 80599 Disque d chappement 1 20 80529 Moteur de vis sans fin 1 21 892665 S...

Страница 31: ...22 Sch ma Des Pi ces...

Страница 32: ...utilis s est peut tre de mauvaise qualit Si possible essayez une autre marque de granul s Essayez aussi une marque compos e d un autre type de bois r sineux plut t que feuillus Des bois diff rents pr...

Страница 33: ...tari re et essayez de le faire fonctionner Si le moteur tourne c est l arbre qui est coinc sur quelque chose Si le moteur ne tourne pas il est d fectueux Tari re bloqu e Commencez par vider la tr mie...

Страница 34: ...ande n envoie pas de courant l allumeur V rifiez la tension qui arrive l allumeur lors du d marrage Ce doit tre la tension nominale Si la tension est inf rieure la valeur nominale v rifiez le c blage...

Страница 35: ...testeur de continuit pour tester l interrupteur de s curit de la tr mie remplacer le si n cessaire L arbre de la tari re est coinc Commencez par vider la tr mie Puis retirez le moteur de la tari re en...

Страница 36: ...le moteur de la tari re en retirant la goupille de la tari re puis retirez les deux boulons qui fixent le support de tari re au tube de tari re Vous pouvez maintenant retirer le support du tube de ta...

Страница 37: ...ateur de combustion Lorsque le po le est en marche v rifiez si le ventilateur de combustion est en fonctionnement Sinon v rifiez l alimentation lectrique du ventilateur de combustion Ce doit tre la te...

Страница 38: ...rchauffe et d clenche l arr t de temp rature interne Enlevez la poussi re des bobinages et pales de ventilateur Si le graissage du ventilateur ne suffit pas il se peut que le ventilateur soit d fectue...

Страница 39: ...rre NE PAS abuser du verre de la porte en frappant en claquant ou en traumatisant similaire N utilisez pas le r chaud avec le verre enlev fissur ou cass MISE EN MARCHE L AUTOMNE Avant de d marrer le p...

Страница 40: ...surez vous que le po le granul s est temp rature ambiante avant de toucher 3 Ouvrez la porte du cendrier retirez le pot de combustion et videz le dans un r cipient m tallique 4 Aspirer pour liminer le...

Страница 41: ...ur acc der ces outs propres vous devez retirer les deux panneaux lat raux Les sorties propres sont fix es la chambre de combustion avec 2 vis 5 16 Retirez les feuilles propres et aspirer les cendres a...

Страница 42: ...tre ou d utiliser ce radiateur bois d une mani re non conforme aux instructions d utilisation de ce manuel GARDEZ LE COUVERCLE DE LA TR MIE FERM TOUT MOMENT SAUF PENDANT LE REMPLISSAGE NE REMPLISSEZ...

Страница 43: ...mat riaux libres qui ressemblent de la sciure ou du sable Il est possible de tamiser les granul s avant de les placer dans la tr mie pour liminer la plupart des fines 2 Des liants Certains granul s s...

Страница 44: ...souhait il revient la plage de chaleur pour laquelle il tait r gl avant de passer en mode T stat si le po le tait r gl sur le niveau de chauffage 5 avant de passer en mode T stat il revient niveau de...

Страница 45: ...rouge situ au dessus du bouton POWER passe au vert lorsqu il est enfonc et reste vert jusqu l arr t du po le Apr s l appui sur le bouton POWER le moteur de la tari re fonctionne pendant 3 5 minutes p...

Страница 46: ...couverte Cela pourrait entra ner un flux d air impr visible au niveau du capuchon de ventilation dans certaines conditions et peut affecter les performances de votre po le ainsi que d autres probl me...

Страница 47: ...le mur est la moins ch re et la plus simple Ne jamais placer la sortie d vacuation sous une terrasse dans une alc ve sous une fen tre ou entre deux fen tres Nous recommandons les kits Simpson Dura Ve...

Страница 48: ...ompos de caoutchouc de silicone r sistant aux variations de temp rature Utiliser une vacuation de 4 po si sa hauteur doit d passer 12 pi 3 66 m ou si l installation se trouve plus de 2 500 pi 762 m d...

Страница 49: ...questions D GAGEMENTS Votre po le granules a t test et r pertori pour une installation dans une maison r sidentielle et mobile conform ment aux d gagements indiqu s ci dessous Pour des raisons de s cu...

Страница 50: ...tre de 1 4 5 16 moins de 8 200 BTU lb humidit inf rieure 8 en poids cendres inf rieure 1 en poids et sel inf rieur 300 parties par million Les granul s mous contenant une quantit excessive de sciure...

Страница 51: ...tes pas fonctionner le po le lorsque la porte d observation est ouverte Dans ce cas la tari re ne distribue pas les granul s et un probl me de s curit peut se poser en raison des tincelles ou des fum...

Страница 52: ...pendant l installation de cet appareil Contactez les autorit s locales du b timent ou des pompiers au sujet des restrictions et des exigences d inspection de l installation dans votre r gion Ces po le...

Отзывы: