United States Stove TH100 Скачать руководство пользователя страница 16

16

© 2023 United States Stove Company

CHIMNEY MAINTENANCE

out the chimney, exposure to the gases in closed or 

confined areas can be dangerous. Make sure your stove 

gaskets and chimney joints are in good working order 

and sealing properly to ensure unintended exposure. It is 

recommended that you use both smoke and CO monitors 

in areas having the potential to generate CO.

GLASS CARE

•  Inspect and clean the glass regularly to detect any 

cracks. If you spot one, turn the stove off immediately. 

Do not abuse the glass door by striking or slamming 

shut. Do not use the stove if the glass is broken.

•  If the glass on your stove breaks, replace only with 

the glass supplied from your heater dealer. Never 

substitute other materials for the glass.

•  To replace the glass, remove the screws retaining the 

glass moldings inside the door. Remove the moldings 

and replace the damaged piece with a new one. 

Perform the procedure backward after replacing it. 

When replacing the glass, you should change the glass 

gasket to make sure you keep it sealed.

•  Never wash the glass with a product that may scratch. 

Use a specialized product, available in the stores where 

wood stoves are sold. The glass should be washed only 

when cold.

GASKET CARE

WARNING:

NEVER OPERATE THE STOVE WITHOUT THE 

GASKET OR WITH A DAMAGED OR BROKEN 

GASKET. OPERATING WITHOUT A GASKET OR 

DAMAGED GASKET WILL RESULT IN DAMAGE TO 

YOUR STOVE AND CAN RESULT IN A HOUSE FIRE.

This unit’s door uses a 5/8” diameter rope gasket. It is 

recommended that you change the door gasket (which 

makes your stove door air tight) once a year, in order 

to ensure good control over the combustion, maximum 

efficiency and security. To change the door gasket, simply 

remove the damaged one. Carefully clean the available 

gasket groove, apply a high temperature silicone sold for 

this purpose, and install the new gasket. You may light 

up your stove again approximately 24 hours after having 

completed this operation.

ATTENTION: 

THIS WOOD HEATER NEEDS PERIODIC INSPECTION 

AND REPAIR FOR PROPER OPERATION. IT IS 

AGAINST FEDERAL REGULATIONS TO OPERATE 

THIS WOOD HEATER IN A MANNER INCONSISTENT 

WITH OPERATING INSTRUCTIONS IN THIS 

MANUAL.

For Parts Assistance Call: 800-750-2723 Ext 5051 or Email: parts@usstove.com

The information in this owner’s manual is specific to your unit. When ordering replacement parts the information 

in this manual will help to ensure the correct items are ordered. Before contacting customer service write down the 

model number and the serial number of this unit. That information can be found on the certification label attached 

to the back of the unit. Other information that may be needed would be the part number and part description of the 

item(s) in question. Part numbers and descriptions can be found in the “Repair Parts” section of this manual. Once 

this information has been gathered you can contact customer service by phone 1-800-750-2723 Ext 5051 or Email  

parts@usstove.com.

Model Information

Model Number
Serial Number

HOW TO ORDER REPAIR PARTS

Содержание TH100

Страница 1: ...ses during the installation of this heater Contact local building or fire officials about permits restrictions and installation requirements in your area NEVER OPERATE THIS PRODUCT WHILE UNATTENDED CA...

Страница 2: ...erall Depth x Width x Height 13 330 mm 16 4 417 mm 26 75 680 mm Combustion Chamber Width x Depth 11 25 x 8 5 286 mm X 216 mm Firebox Volume Cubic Feet 59 cubic feet Door Opening Width x Height 9 6 x 9...

Страница 3: ..._________________________________________ If no Date of inspection of the existing chimney system ___________________________________________________________ COMMISSIONING Confirm Hearth Pad Installat...

Страница 4: ...needed See For use in Mobile home transportable buildings section of this manual LEG INSTALLATION Carefully lay the heater on its back and install all four legs with the hardware provided Note To pre...

Страница 5: ...5 16 18 x 1 1 2 bolts 3 washers and 3 weld tabs provided in the parts box 5 16 18 x 1 1 2 BOLT DIFFUSER WASHER GASKET HEATER TOP WELD TAB Above is an illustration of the installation of the flue coll...

Страница 6: ...IS ROOM HEATER SHALL NOT BE INSTALLED IN A FACTORY BUILT FIREPLACE US Stove highly recommends your stove be installed by a qualified NFI US or WETT Canada technician To find the nearest qualified inst...

Страница 7: ...clearances from combustible materials contact your local safety department Floor to ceiling height must be at least 7 2 13m E F E D B A C Key in mm A 13 331 B 13 331 C 14 5 369 D 18 458 E 10 254 F 15...

Страница 8: ...ur local authority having jurisdiction to determine how many points of attachment are required In addition to the previously detailed installation requirements mobile home transportable building insta...

Страница 9: ...dequate draft may cause back puffing into the room and plugging of the chimney An inadequate draft will cause the appliance to leak smoke into the room through appliance and chimney connector joints A...

Страница 10: ...CHIMNEY Ensure that a masonry chimney meets the minimum standards of the National Fire Protection Association NFPA by having it inspected by a professional Make sure there are no cracks loose mortar...

Страница 11: ...nd cover its opening with a 24 gage minimum sheet metal support Maintain the 6 152 4 mm space There should also be a support sized to fit and hold the metal chimney connector See that the supports are...

Страница 12: ...fic varieties have better energy yields than others Higher efficiencies and lower emissions generally result when burning air dried seasoned hardwoods as compared to softwoods or too green or freshly...

Страница 13: ...ons to alter this setting or otherwise operate this wood heater in a manner inconsistent with operating instructions in this manual EFFICIENCIES Efficiencies can be based on either the lower heating v...

Страница 14: ...Lightupthispapertorch and hold it as close as possible to the mouth of the pipe inside the combustion chamber to warm up the chimney Once the updraft movement is initiated you are ready to ignite the...

Страница 15: ...eposit Leave the air control fully open for about 5 min every time you reload the stove to bring it back to proper operating temperatures The secondary combustion can only take place if the firebox is...

Страница 16: ...RESULT IN A HOUSE FIRE This unit s door uses a 5 8 diameter rope gasket It is recommended that you change the door gasket which makes your stove door air tight once a year in order to ensure good cont...

Страница 17: ...e full width of the appliance plus the 200 mm 8 in required on each side of the appliance without a door Where an appliance is installed less than 200 mm 8 in from a wall the ember pad need only exten...

Страница 18: ...TS Key Part Description Qty 1 83432 5 16 18 X 1 1 2 HX HD C S PL 3 2 83045 Washer 5 16 ID X 3 4 OD X 1 16 THK 3 3 893719 Diffuser 1 4 40292A 6 Flue Collar 1 5 88042 1 4 Rope Gasket 1 6 83431 Weld Tab...

Страница 19: ...rts usstove com Key Part Description Qty 1 893910 Wooden Scale Handle 1 2 893730 Handle 1 3 40909 Door 1 4 88126 5 8 Rope Gasket 1 5 893718 Main Glass 1 6 88174 Gasket Flat Glass 3 16T x 3 8W 1 7 8937...

Страница 20: ...____________________ Engineer Name _____________________________________ License No _________________________________________ Company ___________________________________________ Telephone No _________...

Страница 21: ...rvice 07 Date ______________________ Nom de l ing nieur ________________________________ No de licence ______________________________________ Entreprise ________________________________________ N de t...

Страница 22: ...Description Qt 1 893910 Poign e en bois pour cailles 1 2 893730 Poign e 1 3 40909 Porte 1 4 88126 Joint d tanch it de corde de 1 5 cm 5 8 po 1 5 893718 Verre principal 1 6 88174 Joint Plat verre 3 16T...

Страница 23: ...HD C S PL 3 2 83045 Rondelle 5 16 po ID X 3 4 po OD X 1 16 po THK 3 3 893719 Diffuseur 1 4 40292A Collet de conduit de fum e de 15 cm 6 po 1 5 88042 Joint d tanch it de 6 35 mm 1 4 po 1 6 83431 Langu...

Страница 24: ...n cessite pas de protection de plancher radiant Les pi ces ou mat riaux utiliser pour les protecteurs de braises et les surfaces minimales couvrir et leur relation avec le radiateur d appoint ainsi q...

Страница 25: ...OMMAG OU CASS LE FONCTIONNEMENT SANS JOINT D TANCH IT OU ENDOMMAG ENDOMMAGERA VOTRE PO LE ET PEUT CAUSER UN INCENDIE La porte de cette unit utilise un joint de c ble de 5 8 po de diam tre Il est recom...

Страница 26: ...ec Cela permet des br lages propres et des temp ratures de chemin e plus lev es donc moins de d p ts de cr osote Laissez le contr le de l air compl tement ouvert pendant environ 5 min chaque fois que...

Страница 27: ...vous tes pr t allumer le po le en allumant le papier et en allumant le bois l int rieur de la chambre de combustion Lorsque vous avez atteint un bon lit de braises chaudes nous recommandons les proc...

Страница 28: ...s po les bois c est l humidit dans le bois br l qui quitte le po le sous forme de vapeur Le pouvoir calorifique sup rieur c est lorsque l eau quitte le processus de combustion sous forme enti rement c...

Страница 29: ...ions plus faibles r sultent g n ralement de la combustion de bois feuillus s ch s l air par rapport aux bois tendres ou aux bois feuillus trop verts ou fra chement coup s Les ressources suivantes peuv...

Страница 30: ...au conduit de raccordement en m tal Veillez ce que les supports soient solidement fix s aux surfaces murales sur tous les c t s S assurer que les fixations utilis es pour fixer le conduit de raccorde...

Страница 31: ...avant d installer et d op rer le po le Lors de la connexion du po le travers un mur combustible une chemin e en ma onnerie des m thodes sp ciales sont n cessaires Capuchon en b ton D gagement d un pou...

Страница 32: ...la fuite de fum e de l appareil dans la pi ce travers les joints de l appareil et du conduit de raccordement de la chemin e Une br lure incontr lable ou une temp rature excessive indique un tirage ex...

Страница 33: ...ixation sont n cessaires En plus des exigences d installation d taill es pr c demment les installations de maisons mobiles doivent respecter les exigences suivantes Le radiateur doit tre raccord une c...

Страница 34: ...ctez votre service de s curit local La hauteur du sol au plafond doit tre d au moins 2 13 m 7 pi E F E D B A C Cl po mm A 13 331 B 13 331 C 14 5 369 D 18 458 E 10 254 F 15 5 394 G 60 1524 H 84 2134 G...

Страница 35: ...FABRIQU Nous recommandons que nos produits de foyer des au Canada par le programme de formation technique en nergie du bois WETT CERTIFI US Stove recommande fortement que votre po le soit install par...

Страница 36: ...ntilateur CB36 au support du ventilateur vendu s par ment tape 1 Supprimer tape 2 Attachez tape 3 Attachez ASSEMBLAGE DE COLLET DE CONDUIT Montez le collet du conduit de fum e sur le dessus de l unit...

Страница 37: ...s composants de chemin e et de connecteur de chemin e pour votre installation de chemin e particuli re Des articles suppl mentaires pour les maisons mobiles b timents portatifs peuvent tre n cessaires...

Страница 38: ...________________________ Si non date d inspection du syst me de chemin e existant ___________________________________________________________________________ MISE EN SERVICE Confirmez l installation d...

Страница 39: ...16 4 po 680 mm 26 75 po Chambre de combustion Largeur x Profondeur 286 mm x 216 mm 11 25 x 8 5 po Volume de la bo te feu Pieds cubes 0 59 pi cubes Ouverture de la porte Largeur x Hauteur 244 mm x 244...

Страница 40: ...u des incendies pour conna tre les permis les restrictions et les exigences d installation dans votre r gion NE JAMAIS FAIRE FONCTIONNER CE PRODUIT SANS SURVEILLANCE AVERTISSEMENT Veuillez lire ce man...

Отзывы: