INSTALLATION

THROUGH THE WALL INSTALLATION 

(RECOMMENDED INSTALLATION)

TYPICAL THROUGH THE 

WALL INSTALLATION

Canadian installations must conform to CAN/CSA-B365. 

To vent the unit through the wall, connect the pipe 

adapter to the exhaust motor adapter. If the exhaust 

adapter is at least 18” (457 mm) above ground level, a 

straight section of pellet vent pipe can be used through 

the wall. Your heater dealer should be able to provide 

you with a kit that will handle most of this installation, 

which will include a wall thimble that will allow the proper 

clearance through a combustible wall. Once outside the 

structure, a 3” (76 mm) clearance should be maintained 

from the outside wall and a clean out tee should be 

placed on the pipe with a 90-degree turn away from the 

house. At this point, a 3ft (0.91m) (minimum) section of 

pipe should be added with a horizontal cap, which would 

complete the installation. A support bracket should be 

placed just below the termination cap or one every 4ft 

(1.22m) to make the system more stable. If you live in an 

area that has heavy snowfall, it is recommended that the 

installation be taller than 3ft (0.91m) to get above the 

snowdrift line. This same installation can be used if your 

heater is below ground level by simply adding the clean-

out section and vertical pipe inside until ground level is 

reached. With this installation you have to be aware of the 

snowdrift line, dead grass, and leaves. We recommend 

a 3ft (0.91m) minimum vertical rise on the inside or 

outside of the house. The “through the wall” installation 

is the least expensive and simplest installation. Never 

terminate the end vent under a deck, in an alcove, under 

a window, or between two windows. We recommend 

Simpson Dura-Vent® or Metal-Fab® kits.

THROUGH THE ROOF/CEILING INSTALLATION

•  When venting the heater through the ceiling, the pipe 

is connected the same as through the wall, except the 

clean-out tee is always on the inside of the house, and a 

3” (76 mm) adapter is added before the clean-out tee. 

•  You must use the proper ceiling support flanges and 

roof flashing (supplied by the pipe manufacturer; follow 

the pipe manufacturer’s directions). It is important to 

note that if your vertical run of pipe is more than 12ft 

(3.7m), the pellet vent pipe size should be increased to 

4” (102 mm) in diameter. 

•  Do not exceed more than 4ft (1.22m) of pipe on a 

horizontal run and use as few elbows as possible. If 

an offset is required, it is better to install 45-degree 

elbows rather than 90-degree elbows.

Figure 1

B

C

E

A

Figure 2

A

D

Fresh Air Intake

Exhaust Pipe

Содержание King

Страница 1: ...d this entire manual before you install or use your new room heater Failure to follow instructions may result in property damage bodily injury or even death Improper Installation Will Void Your Warran...

Страница 2: ...s burning wood pellet fuel this heater has been shown to deliver heat at a rate of 8 932 to 25 701 Btu hr This heater achieved a particulate emissions rate of 1 3 g hr when tested to method ASTM E 277...

Страница 3: ...________________________________ If no Date of inspection of existing venting system _________________________________________________________________ COMMISSIONING Confirm Hearth Pad Installation as...

Страница 4: ...TER PLUG OR SEVER THE GROUNDING PLUG DO NOT ROUTE THE ELECTRICAL CORD UNDERNEATH IN FRONT OF OR OVER THE HEATER DO NOT ROUTE THE CORD IN FOOT TRAFFIC AREAS OR PINCH THE CORD UNDER FURNITURE CAUTION BU...

Страница 5: ...lation Canadian installations require 18 450 mm in front of the unit B B D C A B B C Dimensions in mm A Rear through wall 1 25 B Side 6 152 C Front 6 152 D Rear interior vertical 2 50 Canada installat...

Страница 6: ...sher to penetrate paint or protective coating to ensure grounding Vent must be 3 or 4 inch PL Vent and must extend a minimum or 36 914 mm above the roof line of the mobile home and must be installed u...

Страница 7: ...pellet vent pipe is not furnished with the unit and must be purchased separately PELLET VENT INSTALLATION The installation must include a clean out tee to enable collection of fly ash and to permit pe...

Страница 8: ...d your warranty HORIZONTAL EXHAUST VENT INSTALLATION 1 Locate your pellet stove in a location which meets the requirements of this manual but in an area where it does not interfere with the house fram...

Страница 9: ...nowdrift line This same installation can be used if your heater is below ground level by simply adding the clean out section and vertical pipe inside until ground level is reached With this installati...

Страница 10: ...ll with too much fuel and the fire will smother out To much air will result in a flame that is overactive or aggressive The flame in this situation is typically very blue at the bottom and resembles a...

Страница 11: ...ordance to the heat range setting However this speed can be manually operated by pressing the Draft Fan arrows up or down Draft Fan when pressed the display will show Df A which is automatic Press the...

Страница 12: ...the stove cycle between the preselected desired heat range setting 1 to 5 and the minimum heat range setting of 1 The T Stat will not turn the stove on and off When the desired room temperature has be...

Страница 13: ...reduced performance Store your pellets in a dry place DO NOT store the fuel within the installation clearances of the unit or within the space required for refuelling and ash removal Doing so could re...

Страница 14: ...e stove will have to fully shut down and turn off before you will be able to restart the stove IGNITOR 1 Fill hopper and clean burn pot 2 Press the On Off button Make sure the green light comes on 3 A...

Страница 15: ...switch shutting the fuel feed off The stove will shut down and show E2 on the two digit display The stove has to fully shut down before restarting INTERIOR CHAMBERS Burn Pot Periodically remove and c...

Страница 16: ...brush specifically designed for the type of chimney in use A qualified chimney sweep can perform this service It is also recommended that before each heating season the entire system be professionally...

Страница 17: ...gloves carefully remove any loose pieces of glass from the door frame 4 Replace the glass and gasket making sure the gasket runs the full perimeter of the glass edge 5 Re install the retainer and eigh...

Страница 18: ...nd or replace door gaskets Check that all outside connections are clear of any obstructions Check the exhaust system clean as needed Checkthatthepressureswitchconnectiontothefireboxisfreeofashorclearo...

Страница 19: ...he stove is in the Shut Down state waiting for the off button or for a 15 minute period after the stove was turned off or for the stove to cool down or for the door to be closed Flashing dash in Heat...

Страница 20: ...20 2021 United States Stove Company REPAIR PARTS 47 46 48 49 50 1 3 2 4 5 6 8 7 9...

Страница 21: ...30 69763 Exhaust Duct Weldment 1 31 88117 Exhaust Duct Gasket 1 32 80473 Exhaust Blower 1 33 88100 Exhaust Blower Gasket 1 34 80480 Thermistor 1 35 86633 Ignitor Tube Weldment 1 36 80619 Ignitor Cartr...

Страница 22: ...s are ordered Before contacting customer service write down the model number and the serial number of this unit That information can be found on the certification label attached to the back of the uni...

Страница 23: ...______ Engineer Name _____________________________________ License No _________________________________________ Company ___________________________________________ Telephone No _______________________...

Страница 24: ...24 2021 United States Stove Company NOTES...

Страница 25: ...20...

Страница 26: ...gement Weldment 1 20 891141 Vrille 1 21 891189 Top Bushing Plate 1 22 891132 Bague 1 23 83534 Retaining Ring 1 24 69719 Auger Cover 1 25 891161 Bottom Plate Retenue 1 26 25495 Moteur d entra nement Br...

Страница 27: ...18 Sch ma des pi ces 47 46 48 49 50 1 3 2 4 5 6 8 7 9...

Страница 28: ...17 Sch ma de c blage CORRECT FAUX Assurez vous que les ls sont connect s aux deux broches inf rieures de l interrupteur de la tr mie comme illustr...

Страница 29: ...deux fois par seconde Cela indique que le po le fonctionne normalement et qu une condition de temp rature excessive existe provoquant l arr t du combustible Indicateur de r glage du niveau de chaleur...

Страница 30: ...ire V ri ez que le raccordement du pressostat au foyer ne contienne aucune cendre ni obstruction Le syst me vis sans n est bloqu ou il y a une vo te de combustible dans la tr mie qui emp che le combus...

Страница 31: ...lev es VITRE NETTOYAGE RETRAIT ET REMPLACEMENT DE LA VITRE CASS E DE LA PORTE Nettoyage Nous recommandons l utilisation d un nettoyant pour vitres de bonne qualit Si une accumulation de cr osote ou d...

Страница 32: ...r un po le chaud N utilisez jamais le po le avec une vitre cass e une fuite de gaz de combustion pourrait se produire AVERTISSEMENT LE et la chemin e connecteur doit tre maintenu en bon tat et propre...

Страница 33: ...permanents au r chauffeur PREMIER FEU R glez la gamme de chaleur et la vitesse du ventilateur sur un r glage de 3 et laissez le po le fonctionner de cette mani re pendant environ trois 3 heures ou plu...

Страница 34: ...e voyant DEL ON Marche est allum Si l interrupteur de la tr mie est ouvert couvercle ouvert le voyant DEL Heat Range du degr de chaleur s allumera Si le couvercle est ferm le voyant DEL Heat Range du...

Страница 35: ...pas correctement l unit Lorsque vous ajustez le r glage du ventilateur de tirage essayez seulement 1 r glage au dessus ou en dessous du r glage de chaleur Il est pr f rable de laisser le po le en mod...

Страница 36: ...9 Raccordement Du Thermostat...

Страница 37: ...mporte quelle qualit de combustible br le ef cacement en respectant les proc dures d taill es dans le reste de ce manuel Comme une pression de tirage forc e est n cessaire au processus de combustion l...

Страница 38: ...rts appropri es du plafond et le chaperon de toiture fournis par le fabricant de tuyaux respectez les indications du fabricant de tuyaux Il est important de remarquer que si votre section verticale de...

Страница 39: ...pable de vous fournir un kit qui g rera la grande partie de cette installation celui ci devra comprendre un manchon mural qui permettra d obtenir le d gagement correct travers le mur combustible Une f...

Страница 40: ...ines ou nuisibles TYPE DE TIRAGE D AIR POUR GRANUL S Un syst me d vacuation de type PL de 3 ou 4 pouces list UL doit tre utilis pour l installation et connect au raccord de conduite fourni au dos du p...

Страница 41: ...e doit tre suf samment grand pour s tendre sur au moins 6 po 153 mm l avant 6 po 153 mm de chaque c t et 1 po 26 mm derri re le po le La protection du plancher doit s tendre sous et 2 po 51 mm de chaq...

Страница 42: ...ll s r duiront les performances Rangez vos pellets dans un endroit sec NE stockez PAS le carburant dans les d gagements d installation de l appareil ou dans l espace requis pour faire le plein et enle...

Страница 43: ...e Les cendres doivent tre jet es dans un conteneur m tallique avec un couvercle d ajustement serr Le conteneur ferm dans lequel se trouvent les cendres devra tre plac sur une surface non combustible o...

Страница 44: ...s exigences d inspection et d terminer si vous avez besoin d un permis de construire Cet appareil n est pas destin tre utilis en tant que principale source de chaleur U S Environmental Protection Agen...

Отзывы: