MAINTENANCE

CHECK & CLEAN THE HOPPER

Check the hopper periodically to determine if there is any 

sawdust (fines) that is building up in the feed system or 

pellets that are sticking to the hopper surface. Clean as 

needed.

DOOR & GLASS GASKETS

Inspect the main door and glass window gaskets 

periodically. The main door may need to be removed to 

have frayed, broken, or compacted gaskets replaced 

by your authorized dealer. This unit’s door uses a 3/4” 

diameter rope gasket.

BLOWER MOTORS

Clean the air holes on the motors of both the exhaust 

and distribution blowers annually. Remove the exhaust 

blower from the exhaust duct and clean out the internal 

fan blades as part of your fall start-up. If you have indoor 

pets your power motors should be inspected monthly to 

make sure they are free of animal hair build up. Animal 

hair build up in blowers can result in poor performance or 

unforeseen safety hazards.

PAINTED SURFACES

Painted surfaces may be wiped down with a damp cloth. 

If scratches appear, or you wish to renew your paint, 

contact your authorized dealer to obtain a can of suitable 

high-temperature paint.

GLASS

We recommend using a high-quality glass cleaner. Should 

a buildup of creosote or carbon accumulate, you may wish 

to use 000 steel wool and water to clean the glass. DO 

NOT use abrasive cleaners. DO NOT perform the cleaning 

while the glass is HOT. Do not attempt to operate the unit 

with broken glass. Replacement glass may be purchased 

from your U.S. Stove dealer. If the glass is broken, follow 

these removal procedures:
1.  Once the heater has cooled, remove the door from 

the heater.

2.  Remove the rope gasket from the door followed by 

the nuts holding the glass retainer in place.

3.  While wearing gloves, carefully remove any loose 

pieces of glass from the door frame.

4.  Replace the glass and gasket, making sure the gasket 

runs the full perimeter of the glass edge.

5.  Re-install the retainer and eight nuts and rope gasket 

using high-temperature silicone to adhere the gasket 

to the door.

6.  Never use substitute materials for the glass.

DO NOT abuse the door glass by striking, slamming, or 

similar trauma. Do not operate the stove with the glass 

removed, cracked, or broken.

FALL START UP

Prior to starting the first fire of the heating season, 

check the outside area around the exhaust and air intake 

systems for obstructions. Clean and remove any fly ash 

from the exhaust venting system. Clean any screens on 

the exhaust system and on the outside air intake pipe. 

Turn all of the controls on and make sure that they are 

working properly. This is also a good time to give the 

entire stove a good cleaning throughout.

SPRING SHUTDOWN

After the last burn in the spring, remove any remaining 

pellets from the hopper and the auger feed system. Scoop 

out the pellets and then run the auger until the hopper 

is empty and pellets stop flowing (this can be done by 

pressing the “ON” button with the viewing door open). 

Vacuum out the hopper. Thoroughly clean the burn pot, 

and firebox. It may be desirable to spray the inside of the 

cleaned hopper with an aerosol silicone spray if your stove 

is in a high humidity area. The exhaust system should be 

thoroughly cleaned.

MAINTENANCE SCHEDULE

Use the following as a guide under average use conditions. 

Gaskets around door and door glass should be inspected 

and repaired or replaced when necessary.

Daily

Weekly

Monthly or 

as needed

Burn Pot

Stirred

Empty

Combustion 

Chamber

Brushed

Ashes

Check

Empty

Interior Chambers

Vacuumed

Combustion 

Blower Blades

Vacuumed 

/ Brushed

Convection Blower 

Impeller

Vacuumed 

/ Brushed

Vent System

Cleaned

Gaskets

Inspected

Glass

Wiped

Cleaned

Hopper (end of 

season)

Empty & 

Vacuumed

Содержание King

Страница 1: ...d this entire manual before you install or use your new room heater Failure to follow instructions may result in property damage bodily injury or even death Improper Installation Will Void Your Warran...

Страница 2: ...s burning wood pellet fuel this heater has been shown to deliver heat at a rate of 8 932 to 25 701 Btu hr This heater achieved a particulate emissions rate of 1 3 g hr when tested to method ASTM E 277...

Страница 3: ...________________________________ If no Date of inspection of existing venting system _________________________________________________________________ COMMISSIONING Confirm Hearth Pad Installation as...

Страница 4: ...TER PLUG OR SEVER THE GROUNDING PLUG DO NOT ROUTE THE ELECTRICAL CORD UNDERNEATH IN FRONT OF OR OVER THE HEATER DO NOT ROUTE THE CORD IN FOOT TRAFFIC AREAS OR PINCH THE CORD UNDER FURNITURE CAUTION BU...

Страница 5: ...lation Canadian installations require 18 450 mm in front of the unit B B D C A B B C Dimensions in mm A Rear through wall 1 25 B Side 6 152 C Front 6 152 D Rear interior vertical 2 50 Canada installat...

Страница 6: ...sher to penetrate paint or protective coating to ensure grounding Vent must be 3 or 4 inch PL Vent and must extend a minimum or 36 914 mm above the roof line of the mobile home and must be installed u...

Страница 7: ...pellet vent pipe is not furnished with the unit and must be purchased separately PELLET VENT INSTALLATION The installation must include a clean out tee to enable collection of fly ash and to permit pe...

Страница 8: ...d your warranty HORIZONTAL EXHAUST VENT INSTALLATION 1 Locate your pellet stove in a location which meets the requirements of this manual but in an area where it does not interfere with the house fram...

Страница 9: ...nowdrift line This same installation can be used if your heater is below ground level by simply adding the clean out section and vertical pipe inside until ground level is reached With this installati...

Страница 10: ...ll with too much fuel and the fire will smother out To much air will result in a flame that is overactive or aggressive The flame in this situation is typically very blue at the bottom and resembles a...

Страница 11: ...ordance to the heat range setting However this speed can be manually operated by pressing the Draft Fan arrows up or down Draft Fan when pressed the display will show Df A which is automatic Press the...

Страница 12: ...the stove cycle between the preselected desired heat range setting 1 to 5 and the minimum heat range setting of 1 The T Stat will not turn the stove on and off When the desired room temperature has be...

Страница 13: ...reduced performance Store your pellets in a dry place DO NOT store the fuel within the installation clearances of the unit or within the space required for refuelling and ash removal Doing so could re...

Страница 14: ...e stove will have to fully shut down and turn off before you will be able to restart the stove IGNITOR 1 Fill hopper and clean burn pot 2 Press the On Off button Make sure the green light comes on 3 A...

Страница 15: ...switch shutting the fuel feed off The stove will shut down and show E2 on the two digit display The stove has to fully shut down before restarting INTERIOR CHAMBERS Burn Pot Periodically remove and c...

Страница 16: ...brush specifically designed for the type of chimney in use A qualified chimney sweep can perform this service It is also recommended that before each heating season the entire system be professionally...

Страница 17: ...gloves carefully remove any loose pieces of glass from the door frame 4 Replace the glass and gasket making sure the gasket runs the full perimeter of the glass edge 5 Re install the retainer and eigh...

Страница 18: ...nd or replace door gaskets Check that all outside connections are clear of any obstructions Check the exhaust system clean as needed Checkthatthepressureswitchconnectiontothefireboxisfreeofashorclearo...

Страница 19: ...he stove is in the Shut Down state waiting for the off button or for a 15 minute period after the stove was turned off or for the stove to cool down or for the door to be closed Flashing dash in Heat...

Страница 20: ...20 2021 United States Stove Company REPAIR PARTS 47 46 48 49 50 1 3 2 4 5 6 8 7 9...

Страница 21: ...30 69763 Exhaust Duct Weldment 1 31 88117 Exhaust Duct Gasket 1 32 80473 Exhaust Blower 1 33 88100 Exhaust Blower Gasket 1 34 80480 Thermistor 1 35 86633 Ignitor Tube Weldment 1 36 80619 Ignitor Cartr...

Страница 22: ...s are ordered Before contacting customer service write down the model number and the serial number of this unit That information can be found on the certification label attached to the back of the uni...

Страница 23: ...______ Engineer Name _____________________________________ License No _________________________________________ Company ___________________________________________ Telephone No _______________________...

Страница 24: ...24 2021 United States Stove Company NOTES...

Страница 25: ...20...

Страница 26: ...gement Weldment 1 20 891141 Vrille 1 21 891189 Top Bushing Plate 1 22 891132 Bague 1 23 83534 Retaining Ring 1 24 69719 Auger Cover 1 25 891161 Bottom Plate Retenue 1 26 25495 Moteur d entra nement Br...

Страница 27: ...18 Sch ma des pi ces 47 46 48 49 50 1 3 2 4 5 6 8 7 9...

Страница 28: ...17 Sch ma de c blage CORRECT FAUX Assurez vous que les ls sont connect s aux deux broches inf rieures de l interrupteur de la tr mie comme illustr...

Страница 29: ...deux fois par seconde Cela indique que le po le fonctionne normalement et qu une condition de temp rature excessive existe provoquant l arr t du combustible Indicateur de r glage du niveau de chaleur...

Страница 30: ...ire V ri ez que le raccordement du pressostat au foyer ne contienne aucune cendre ni obstruction Le syst me vis sans n est bloqu ou il y a une vo te de combustible dans la tr mie qui emp che le combus...

Страница 31: ...lev es VITRE NETTOYAGE RETRAIT ET REMPLACEMENT DE LA VITRE CASS E DE LA PORTE Nettoyage Nous recommandons l utilisation d un nettoyant pour vitres de bonne qualit Si une accumulation de cr osote ou d...

Страница 32: ...r un po le chaud N utilisez jamais le po le avec une vitre cass e une fuite de gaz de combustion pourrait se produire AVERTISSEMENT LE et la chemin e connecteur doit tre maintenu en bon tat et propre...

Страница 33: ...permanents au r chauffeur PREMIER FEU R glez la gamme de chaleur et la vitesse du ventilateur sur un r glage de 3 et laissez le po le fonctionner de cette mani re pendant environ trois 3 heures ou plu...

Страница 34: ...e voyant DEL ON Marche est allum Si l interrupteur de la tr mie est ouvert couvercle ouvert le voyant DEL Heat Range du degr de chaleur s allumera Si le couvercle est ferm le voyant DEL Heat Range du...

Страница 35: ...pas correctement l unit Lorsque vous ajustez le r glage du ventilateur de tirage essayez seulement 1 r glage au dessus ou en dessous du r glage de chaleur Il est pr f rable de laisser le po le en mod...

Страница 36: ...9 Raccordement Du Thermostat...

Страница 37: ...mporte quelle qualit de combustible br le ef cacement en respectant les proc dures d taill es dans le reste de ce manuel Comme une pression de tirage forc e est n cessaire au processus de combustion l...

Страница 38: ...rts appropri es du plafond et le chaperon de toiture fournis par le fabricant de tuyaux respectez les indications du fabricant de tuyaux Il est important de remarquer que si votre section verticale de...

Страница 39: ...pable de vous fournir un kit qui g rera la grande partie de cette installation celui ci devra comprendre un manchon mural qui permettra d obtenir le d gagement correct travers le mur combustible Une f...

Страница 40: ...ines ou nuisibles TYPE DE TIRAGE D AIR POUR GRANUL S Un syst me d vacuation de type PL de 3 ou 4 pouces list UL doit tre utilis pour l installation et connect au raccord de conduite fourni au dos du p...

Страница 41: ...e doit tre suf samment grand pour s tendre sur au moins 6 po 153 mm l avant 6 po 153 mm de chaque c t et 1 po 26 mm derri re le po le La protection du plancher doit s tendre sous et 2 po 51 mm de chaq...

Страница 42: ...ll s r duiront les performances Rangez vos pellets dans un endroit sec NE stockez PAS le carburant dans les d gagements d installation de l appareil ou dans l espace requis pour faire le plein et enle...

Страница 43: ...e Les cendres doivent tre jet es dans un conteneur m tallique avec un couvercle d ajustement serr Le conteneur ferm dans lequel se trouvent les cendres devra tre plac sur une surface non combustible o...

Страница 44: ...s exigences d inspection et d terminer si vous avez besoin d un permis de construire Cet appareil n est pas destin tre utilis en tant que principale source de chaleur U S Environmental Protection Agen...

Отзывы: