6
© 2022 United States Stove Company
IMPROPER INSTALLATION
The use of other components other than stated herein
could cause bodily harm, heater damage, and void your
warranty. The manufacturer will not be held responsible
for damage caused by the malfunction of a stove due to
improper venting or installation.
FLOOR PROTECTION
This heater must have a non-combustible floor protector
(UL1618 ember protection) installed beneath it if the floor
is of combustible material. The floor protector should
be listed to UL 1618 or equivalent to type 1 ember floor
protection. The floor protection must extend 6” to the
front, 6” on each side and 1” to the rear of the appliance
See diagram for further information
A Back to Stove
1”
26mm
B Side to Stove
6” 153 mm
C Front to Stove
6” 153 mm
D Back to Flue
2”
51 mm
CLEARANCES
Your pellet stove has been tested and listed for installation
in residential, mobile home in accordance with the
clearances given below. For safety reasons, please adhere
to the installation clearances and restrictions. Any
reduction in clearance to combustibles may only be done
by means approved by a regulatory authority.
E Side Wall to Stove
8”
235 mm
F Side Wall to PL Vent Pipe
10”
254 mm
G Back Wall to Stove
9.25”
235 mm
H Back Wall to PL Vent Pipe
3”
76 mm
J Ceiling to Floor
60”
1524 mm
K Ceiling to Stove
27.5
699 mm
L Wall to Stove
7-1/2”
191 mm
M Side Wall to PL Vent Pipe 11-1/4”
286 mm
N Wall to PL Vent Pipe
7-1/2”
191 mm
OUTSIDE AIR SUPPLY
(OPTIONAL, UNLESS
INSTALLING IN A MOBILE HOME)
Depending on your location and home construction,
outside air may be necessary for optimal performance.
Your stove is approved to be installed with an outside air
intake (69FAK) which is necessary for a mobile home.
You can purchase the 69FAK through your heater dealer.
INSTALLATION
FOR CUSTOMER SERVICE CALL: 800-750-2723 EXT 5050
Содержание KING KP5513
Страница 28: ...28 2022 United States Stove Company NOTES...