Display is Flashing “E3”
Possible Causes

Possible Remedies: (Unplug stove first when possible)

The hopper is out of pellets

Refill the hopper.

The air dampener is too far open for a low feed 

setting

If on the low setting, you may need to close the dampener all the 

way.

The burnpot holes are blocked.

Remove the burnpot and thoroughly clean it.

The air inlet, the interior chambers, or exhaust 

system has a partial blockage.

Follow all cleaning procedures in the maintenance section of the 

owner's manual

The hopper safety switch has failed or hopper is 

open.

When operating the unit, be sure the hopper lid is closed so that 

the hopper safety switch will activate. Check the wires leading 

from the hopper safety switch to the control panel and auger 

motor for secure connections. Use a continuity tester to test the 

hopper safety switch; replace if necessary.

The auger shaft is jammed.

"Start by emptying the hopper. Then remove the auger motor by 

removing the auger pin, then remove the two bolts that hold the 

auger bracket to the auger tube. The auger bracket will now be 

able to be removed form the auger tube. Remove the two bolts 

on the side of the auger tube to remove the lower bearing of the 

auger. Pull the auger out of the tube to free the jam.

The auger motor has failed.

Remove the auger motor from the auger shaft and try to run the 

unit. If the motor will turn the shaft is jammed on something. If 

the motor will not turn, the motor is bad.

The Proof of Fire (POF) thermodisc has 

malfunctioned.

Temporarily bypass the POF thermodisc by disconnecting the 

two wires and connecting them with a short piece of wire. Then 

plug the stove back up. If the stove comes on and works, you need 

to replace the POF thermodisc. This is for testing only. DO NOT 

LEAVE THE THERMODISC BYPASSED. Your blowers will never 

shut off and if the fire went out the auger will continue to feed 

pellets until the hopper is empty if you leave the POF thermodisc 

bypassed.

The control board is not sending power to the POF 

thermodisc or other auger system components.

There should be a 5-volt (approximately) current going to the 

POF thermodisc after the stove has been on for 10 minutes.

TROUBLESHOOTING GUIDE

Содержание KING KP5513

Страница 1: ...r fire officials about permits restrictions and installation requirements in your area NEVER OPERATE THIS PRODUCT WHILE UNATTENDED CAUTION Please read this entire manual before you install or use your...

Страница 2: ...OPERATE THIS WOOD HEATER IN A MANNER INCONSISTENT WITH THE OPERATING INSTRUCTIONS IN THE OWNER S MANUAL Heating Specifications Fuel Burn Rate lowest setting 1 65 lbs hr 0 75 kg hr Pellet size may eff...

Страница 3: ...and_____________________________________________ If no Date of inspection of existing venting system ________________________________________________________________ COMMISSIONING Confirm Hearth Pad I...

Страница 4: ...ed wires out of the top of the stove There will be two wire harnesses as shown 2 Unpack the top mount controls and ensure that the wiring harness shown is attached securely 3 Connect the factory insta...

Страница 5: ...IS REQUIRED THIS UNIT MUST BE PLUGGED INTO A 110 120V 60 HZ GROUNDED ELECTRICAL OUTLET DO NOT USE AN ADAPTER PLUG OR SEVER THE GROUNDING PLUG DO NOT ROUTE THE ELECTRICAL CORD UNDERNEATH IN FRONT OF O...

Страница 6: ...urpelletstovehasbeentestedandlistedforinstallation in residential mobile home in accordance with the clearances given below For safety reasons please adhere to the installation clearances and restrict...

Страница 7: ...mobile home all exterior venting must be removed while the mobile home is being relocated After relocation all venting must be reinstalled and securely fastened Outside Air is mandatory for mobile ho...

Страница 8: ...nd to permit periodic cleaning of the exhaust system 90 degree elbows accumulate fly ash and soot thereby reducing exhaust flow and performance of the stove Each elbow or tee reduces draft potential b...

Страница 9: ...ater is below ground level by simply adding the clean out section and vertical pipe inside until ground level is reached With this installation you have to be aware of the snowdrift line dead grass an...

Страница 10: ...venting system You must have the existing chimney system cleaned and or inspected by a qualified chimney sweep before proceeding with the installation of your pellet stove 2 To the right is an exampl...

Страница 11: ...raph starting from heat range 1 to heat range 5 C C F Button The C F button changes the two digit display from degrees Celsius to degrees Fahrenheit D MODE M T BUTTON The Mode of the stove can be swit...

Страница 12: ...paper cardboard saw dust wax and similar substances for the purpose of starting a fire in an affected wood heater Burning these materials may result in release of toxic fumes or render the heater ine...

Страница 13: ...e will emit an odor as the high temperature paint cures or becomes seasoned to the metal Maintaining smaller fires will minimize this Avoid placing items on the stovetop during this period because the...

Страница 14: ...minutes or longer depending on the heat remaining in the appliance After the stove components stop running all lights on the display will go out and the two digit display will begin flashing E3 REFUE...

Страница 15: ...m and the damper should be open for these settings If the door is opened while the stove is in operation it must be closed within 30 seconds or the stove will shut down If the stove shuts down push th...

Страница 16: ...occurred If creosote has accumulated it should be removed to reduce the risk of a chimney fire Inspect the system at the stove connection and at the chimney top Cooler surfaces tend to build creosote...

Страница 17: ...ing the potential to generate CO CHECK CLEAN THE HOPPER Check the hopper periodically to determine if there is any sawdust fines that is building up in the feed system or pellets that are sticking to...

Страница 18: ...ambers Vacuumed Combustion Blower Blades Vacuumed Brushed Convection Blower Impeller Vacuumed Brushed Vent System Cleaned Gaskets Inspected Glass Wiped Cleaned Hopper end of season Empty Vacuumed For...

Страница 19: ...ose the slide about 1 4 after your stove cools down Restart your stove If your display shows E1 again close the slide another 1 4 and restart The convection blower is overheating and tripping the inte...

Страница 20: ...ombustion blower failure With the stove on check to see if the combustion blower is running If it is not you will need to check for power going to the combustion blower It should be a full current If...

Страница 21: ...move the two bolts that hold the auger bracket to the auger tube The auger bracket will now be able to be removed form the auger tube Remove the two bolts on the side of the auger tube to remove the l...

Страница 22: ...ating the unit be sure the hopper lid is closed so that the hopper safety switch will activate Check the wires leading from the hopper safety switch to the control panel and auger motor for secure con...

Страница 23: ...The Home Possible Causes Possible Remedies Unplug stove first when possible There is a leak in the vent pipe system Inspect all vent pipe connections Make sure they are sealed with RTV silicone that...

Страница 24: ...e caused a jam Loose wire or connector Check all wires and connectors that connector to the auger motor high limit switch and the Molex connector Bad control board If the fuse is good the wires and co...

Страница 25: ...l Burnpot holes are blocked Remove the burnpot and thoroughly clean it Blockage in air intake pipe Visually inspect the air intake pipe that leads into the burnpot for foreign material Combustion blow...

Страница 26: ...er Gasket 2 8 80630 Housing PCBA Controller 1 9 80631 Power Board 1 10 80491 Microswitch 1 11 80709 Room Blower 1 12 88347 High Temp Snapdisc Gasget 2 13 80601 High Temp Snapdisc Air 1 14 80599 T Disc...

Страница 27: ...2022 United States Stove Company 27 1 25A 250V FUSE 7 5A 250V FUSE CORRECT WRONG Ensure the wires are connected to the bottom two prongs of the hopper switch as shown WIRING DIAGRAM...

Страница 28: ...28 2022 United States Stove Company NOTES...

Страница 29: ...______ Engineer Name _____________________________________ License No _________________________________________ Company ___________________________________________ Telephone No _______________________...

Страница 30: ...ed States Stove Company 27 1 25A 250V Fusible 7 5A 250V Fusible CORRECT FAUX Assurez vous que les fils sont connect s aux deux broches inf rieures de l interrupteur de la tr mie comme illustr SCH MA D...

Страница 31: ...nde IR 1 4 69762 Pot de feu 1 5 892668 Couvercles de nettoyage des cendres 2 6 892199 Bo tier contr leur PCBA 1 7 80491 Commutateur de couvercle 1 8 80709 Sou eur de pi ce 1 9 80834 T Disc joint d air...

Страница 32: ...lot de granul s utilis s est peut tre de mauvaise qualit Si possible essayez une autre marque de granul s Essayez aussi une marque compos e d un autre type de bois r sineux plut t que feuillus Des boi...

Страница 33: ...de l arbre de la tari re et essayez de le faire fonctionner Si le moteur tourne c est l arbre qui est coinc sur quelque chose Si le moteur ne tourne pas il est d fectueux Tari re bloqu e Commencez par...

Страница 34: ...e tableau de commande n envoie pas de courant l allumeur V rifiez la tension qui arrive l allumeur lors du d marrage Ce doit tre la tension nominale Si la tension est inf rieure la valeur nominale v r...

Страница 35: ...rm pour permettre l interrupteur de s curit de la tr mie de s activer V rifiez le branchement des fils qui partent de l interrupteur de s curit de la tr mie jusqu au tableau de commande et au moteur d...

Страница 36: ...Retirez ensuite le moteur de la tari re en retirant la goupille de la tari re puis retirez les deux boulons qui fixent le support de tari re au tube de tari re Vous pouvez maintenant retirer le suppo...

Страница 37: ...Panne du ventilateur de combustion Lorsque le po le est en marche v rifiez si le ventilateur de combustion est en fonctionnement Sinon v rifiez l alimentation lectrique du ventilateur de combustion Ce...

Страница 38: ...e po le Si votre cran affiche nouveau E1 fermez la glissi re de 1 4 et recommencez Le ventilateur de convection surchauffe et d clenche l arr t de temp rature interne Enlevez la poussi re des bobinage...

Страница 39: ...propri taire sont sp cifiques votre appareil Lors de la commande de pi ces de rechange les informations contenues dans ce manuel vous aideront vous assurer que les bons articles sont command s Avant d...

Страница 40: ...N UTILISEZ PAS de nettoyants abrasifs N effectuez PAS le nettoyage lorsque la vitre est CHAUDE N essayez pas de faire fonctionner l appareil avec du verre bris Le verre de remplacement peut tre achet...

Страница 41: ...son de chauffage Pour nettoyer la chemin e d connecter l vacuation du po le CENDRES VOLANTES Elles s accumulent dans la portion horizontale du conduit d vacuation Bien qu elles ne soient pas combustib...

Страница 42: ...dans le pot de combustion pour liminer toute accumulation qui peut emp cher l air de se d placer travers le pot de combustion librement Echangeur de chaleur Il y a une plaque nettoyer des deux c t s d...

Страница 43: ...du po le tous les t moins de l cran s teignent et l cran deux chiffres affiche E3 en clignotant RECHARGE EN COMBUSTIBLE AVERTISSEMENT LA TR MIE ET LE COUVERCLE DU PO LE SONT CHAUDS PENDANT LE FONCTION...

Страница 44: ...de combustion ne contient pas de granul s N ouvrez PAS la porte de visualisation Il se peut que le registre doive tre ferm pendant le d marrage N ajoutez PAS de granul s dans le pot de combustion la...

Страница 45: ...particules L interdiction de la combustion de ces mat riaux n interdit pas l utilisation des d marreurs de feu fabriqu s partir de papier de carton de sciure de cire et substances similaires dans le...

Страница 46: ...eaux de production de chaleur changent progressivement sur le diagramme en barres passant du niveau 1 au niveau 5 de chauffage C Touche C F La touche C F fait passer l affichage deux chiffres des degr...

Страница 47: ...ers un tuyau de connecteur de 6 pouces les illustrations ci dessous ne sont que des exemples Veuillez con rmer tous les codes du b timent locaux ou ragulations ayant comp tence avant de demander un in...

Страница 48: ...tion de tuyau d au moins 3 pi 0 91 m doit tre ajout e avec un chapeau horizontal pour achever l installation Un support doit tre plac juste au dessous du chapeau de sortie ou raison d un support tous...

Страница 49: ...e conduit d vacuation pour po le granul s est con u pour tre d mont aux fins de nettoyage et doit tre v rifi plusieurs fois au cours de la saison de chauffage Le conduit d vacuation pour po le granul...

Страница 50: ...ou 101 mm et doit d passer d au moins 36 po 914 mm au dessus de la fa ti re de la maison mobile elle doit tre install e avec un pare feu de plafond et un chapeau anti pluie homologu s UL En cas de d p...

Страница 51: ...A Retour Cuisini re U S A 1 26 CAN 8 204 B C t po le U S A 6 153 CAN 8 204 C De l avant au po le U S A 6 153 CAN 8 204 D Retour Flue 2 51 D GAGEMENTS Votre po le granules a t test et r pertori pour un...

Страница 52: ...ASSAGE ET NE LE COINCEZ PAS SOUS LES MEUBLES ATTENTION ATTENTION LA COMBUSTION DU COMBUSTIBLE G N RE DU MONOXYDE DE CARBONE QUI PEUT S AV RER DANGEREUX POUR LA SANT EN L ABSENCE D UNE VENTILATION APPR...

Страница 53: ...bles comme illustr 2 D ballez les meilleurs contr les de montage et de veiller ce que le faisceau de c blage illustr est fix 3 Connecter les install s en usine faisceaux de c blage sur le panneau de c...

Страница 54: ...n date d inspection du syst me de ventilation existant ___________________________________________________________________ MISE EN SERVICE Confirmer l installation du tapis de foyer conform ment aux i...

Страница 55: ...uel d crit l installation et le fonctionnement du po le bois USSC 5710 XH Cet appareil de chauffage respecte les limites d mission de bois de berceau de l Environmental Protection Agency des tats Unis...

Страница 56: ...ion de ce radiateur Contactez les responsables locaux du b timent ou des pompiers pour conna tre les permis les restrictions et les exigences d installation dans votre r gion NE JAMAIS UTILISER CE PRO...

Отзывы: