background image

© 202

2 Unit

ed Sta

tes S

tov

e Compan

y

5

INSTALL

ATION

AVIS DE SÉ

CURITÉ

• 

SI CE 

POÊLE 

N’EST 

PAS 

INSTALLÉ 

CORRE

CTEMENT

UN INCENDIE PEUT EN RÉSUL

TER. P

OUR 

RÉDUIRE LE

S RISQ

UES D

’INCENDIE, SUIVEZ LE

INSTR

UCTIONS D

’INSTALL

ATION.

• 

ADRESSEZ

-VO

US A

UX A

UTORITÉ

S LOC

ALES 

DE L’URB

ANISME PO

UR OBTENIR UN PERMIS 

ET DES RENSEIGNEMENT

S SUR T

OUTE A

UTRE 

RESTRIC

TION À L’INS

TALL

ATION ET S

UR LES 

EXIGENCES D

’INSPECTION D

ANS VO

TRE RÉGION.

• 

NE PLA

CEZ AUC

UN VÊTEMENT OU A

UTRE OBJET 

INFLAMMABLE S

UR OU PRÈ

S DU P

OÊLE.

• 

N’UTILISEZ JAMAIS D

’ESSENCE, DE C

OMBU

STIBLE 

À LANTERNE DE TYPE E

SSENCE, DE KÉR

OSÈNE, 

D’E

SSENCE D

’ALL

UME-FEU O

U D’A

UTRES LIQ

UIDES 

SIMILAIRE

S PO

UR ALLUMER O

U RAVIVER LE FEU 

DANS CE P

OÊLE. GARDEZ TO

US CE

S LIQUIDE

ÉLOIGNÉ

S DU P

OÊLE LOR

SQ

U’IL EST EN MAR

CHE.

• 

CET APPAREIL E

ST UN APP

AREIL DE CHAUFF

AGE 

AUT

ONOME. IL N’EST P

AS C

ONÇU P

OUR ÊTRE RELIÉ 

À DE

S COND

UITS 

DE DIS

TRIBUTION 

D’AIR

. CE 

N’EST 

PAS UN F

OURNEA

U.

• 

INSTALLER L'ÉVENT A

UX DÉ

GAGEMENT

S SPÉCIFIÉ

PAR LE F

ABRICANT DE L'ÉVENT

.

• 

N’INSTALLEZ P

AS DE RE

GISTRE DE TIR

AGE S

UR LE 

SYS

TÈME D’ÉV

ACU

ATION DE CET APP

AREIL. 

• 

CE POÊLE DOIT ÊTRE RÉ

GULIÈREMENT ENTRETENU 

ET NETTO

YÉ (VOIR L

A SECTION « ENTRETIEN 

»). LE DÉFAUT D

’ENTRETIEN DU P

OÊLE PEUT 

ENTRAÎNER UN F

ONCTIONNEMENT INAPPR

OPRIÉ 

ET DANGEREU

X.

• 

UN DISJONC

TEUR DOIT ÊTRE INSTALLÉ. CET 

APPAREIL DOIT ÊTRE BR

ANCHÉ SUR UNE PRISE 

MURALE A

VEC TERRE DE 110

-12

0 V, 60 

Z. N’UTILISEZ 

PAS D

’AD

APTA

TEUR DE PRISE ET NE CO

UPEZ PAS 

LA FICHE DE TERRE. N’

ACHEMINEZ P

AS LE C

ORDON 

ÉLECTRIQ

UE SO

US, DEV

ANT OU S

UR LE POÊLE. NE 

FAITE

S PAS C

OURIR LE C

ORDON ÉLECTRIQ

UE DANS 

LES Z

ONES DE P

ASS

AGE ET NE LE C

OINCEZ PAS 

SO

US LE

S MEUBLES.

ATTENTION:

ATTENTION: 

LA C

OMBU

STION D

U COMB

USTIBLE 

GÉNÈRE D

U  MONO

XYDE 

DE CARB

ONE Q

UI PEUT 

S’A

VÉRER DANGEREU

X PO

UR LA S

ANTÉ EN L’AB

SENCE 

D’UNE VENTIL

ATION APPR

OPRIÉE.

ATTENTION:

• 

UN DÉTE

CTEUR 

DE FUMÉE FONC

TIONNEL DOIT 

ÊTRE INSTALLÉ D

ANS LA PIÈ

CE OÙ SE TR

OU

VE LE 

POÊLE.

• 

INSTALLEZ UN DÉTE

CTEUR DE FUMÉE À CHA

QUE 

ÉTAGE DE V

OTRE MAIS

ON; EN CA

S D’INCENDIE 

ACCIDENTEL D

Û À N’IMPOR

TE QUELLE C

AU

SE, 

CE DISPO

SITIF PEUT LAIS

SER LE TEMPS DE 

S’É

CHAPPER.

• 

LE DÉTE

CTEUR 

DE FUMÉE 

DOIT ÊTRE 

INSTALLÉ 

À 

AU MOINS 15 

PIEDS (

4,5

7  M) DE L

’APP

AREIL AFIN 

D’ÉVITER Q

U’IL NE SE DÉCLENCHE INUTILEMENT 

LOR

S DU RE

CHARGEMENT D

U POÊLE.

ATTENTION:

• 

L’UTILIS

ATION D

’AIR EX

TÉRIEUR N’EST P

AS 

NÉCE

SSAIRE P

OUR CET APP

AREIL.

• 

NE DÉBRANCHEZ P

AS 

LE POÊLE 

SI VO

US 

SO

UPÇ

ONNEZ UN 

DYSF

ONCTIONNEMENT

. PLA

CEZ 

LE CONT

ACTEUR ON/

OFF SUR « OFF » PUIS PRENEZ 

CONT

ACT A

VEC LE C

ONCESSIONNAIRE.

• 

LE POÊLE NE F

ONCTIONNE 

PAS PEND

ANT LE

CO

UPURES 

DE CO

URANT

. EN 

CA

S DE 

PANNE 

DE 

CO

URANT

, VEILLEZ AUX ÉMANA

TIONS DE FUMÉE 

DU P

OÊLE ET OU

VREZ UNE FENÊTRE SI LA FUMÉE 

SE RÉPAND D

ANS LA PIÈ

CE.

• 

N’OB

STR

UEZ JAMAIS L

A CIRCUL

ATION DE L

’AIR DE

GRILLES D

’AÉR

ATION O

UVER

TES DE L

’APP

AREIL.

US S

tov

e rec

ommande for

temen

t que votr

e poêle soit ins

tallé 

par un technicien qualifié NFI (

US) ou WET

T (Canada

). Pour 

trouv

er l’ins

talla

teur qualifié le plus pr

oche, ac

céde

z à:

http

s://n

ficer

tified.or

g,

http

s://w

ww

.w

ettinc.

ca/

INSTALL

ATION INC

ORRECTE

L’utilis

ation d’

autr

es compo

san

ts a

utres que c

eux indiqués dans 

le prés

ent doc

ument pourr

ait caus

er des blessur

es corpor

elles, 

des domma

ges a

u radia

teur 

et 

annuler vo

tre 

gar

antie

. Le 

fabric

ant ne s

era pa

s tenu r

esponsable des domma

ges c

aus

és 

par le 

dysf

onctionnemen

t d’

un poêle 

en rais

on d’une v

entila

tion 

ou d’une ins

talla

tion incorr

ecte

.

Содержание KING KP5513

Страница 1: ...r fire officials about permits restrictions and installation requirements in your area NEVER OPERATE THIS PRODUCT WHILE UNATTENDED CAUTION Please read this entire manual before you install or use your...

Страница 2: ...OPERATE THIS WOOD HEATER IN A MANNER INCONSISTENT WITH THE OPERATING INSTRUCTIONS IN THE OWNER S MANUAL Heating Specifications Fuel Burn Rate lowest setting 1 65 lbs hr 0 75 kg hr Pellet size may eff...

Страница 3: ...and_____________________________________________ If no Date of inspection of existing venting system ________________________________________________________________ COMMISSIONING Confirm Hearth Pad I...

Страница 4: ...ed wires out of the top of the stove There will be two wire harnesses as shown 2 Unpack the top mount controls and ensure that the wiring harness shown is attached securely 3 Connect the factory insta...

Страница 5: ...IS REQUIRED THIS UNIT MUST BE PLUGGED INTO A 110 120V 60 HZ GROUNDED ELECTRICAL OUTLET DO NOT USE AN ADAPTER PLUG OR SEVER THE GROUNDING PLUG DO NOT ROUTE THE ELECTRICAL CORD UNDERNEATH IN FRONT OF O...

Страница 6: ...urpelletstovehasbeentestedandlistedforinstallation in residential mobile home in accordance with the clearances given below For safety reasons please adhere to the installation clearances and restrict...

Страница 7: ...mobile home all exterior venting must be removed while the mobile home is being relocated After relocation all venting must be reinstalled and securely fastened Outside Air is mandatory for mobile ho...

Страница 8: ...nd to permit periodic cleaning of the exhaust system 90 degree elbows accumulate fly ash and soot thereby reducing exhaust flow and performance of the stove Each elbow or tee reduces draft potential b...

Страница 9: ...ater is below ground level by simply adding the clean out section and vertical pipe inside until ground level is reached With this installation you have to be aware of the snowdrift line dead grass an...

Страница 10: ...venting system You must have the existing chimney system cleaned and or inspected by a qualified chimney sweep before proceeding with the installation of your pellet stove 2 To the right is an exampl...

Страница 11: ...raph starting from heat range 1 to heat range 5 C C F Button The C F button changes the two digit display from degrees Celsius to degrees Fahrenheit D MODE M T BUTTON The Mode of the stove can be swit...

Страница 12: ...paper cardboard saw dust wax and similar substances for the purpose of starting a fire in an affected wood heater Burning these materials may result in release of toxic fumes or render the heater ine...

Страница 13: ...e will emit an odor as the high temperature paint cures or becomes seasoned to the metal Maintaining smaller fires will minimize this Avoid placing items on the stovetop during this period because the...

Страница 14: ...minutes or longer depending on the heat remaining in the appliance After the stove components stop running all lights on the display will go out and the two digit display will begin flashing E3 REFUE...

Страница 15: ...m and the damper should be open for these settings If the door is opened while the stove is in operation it must be closed within 30 seconds or the stove will shut down If the stove shuts down push th...

Страница 16: ...occurred If creosote has accumulated it should be removed to reduce the risk of a chimney fire Inspect the system at the stove connection and at the chimney top Cooler surfaces tend to build creosote...

Страница 17: ...ing the potential to generate CO CHECK CLEAN THE HOPPER Check the hopper periodically to determine if there is any sawdust fines that is building up in the feed system or pellets that are sticking to...

Страница 18: ...ambers Vacuumed Combustion Blower Blades Vacuumed Brushed Convection Blower Impeller Vacuumed Brushed Vent System Cleaned Gaskets Inspected Glass Wiped Cleaned Hopper end of season Empty Vacuumed For...

Страница 19: ...ose the slide about 1 4 after your stove cools down Restart your stove If your display shows E1 again close the slide another 1 4 and restart The convection blower is overheating and tripping the inte...

Страница 20: ...ombustion blower failure With the stove on check to see if the combustion blower is running If it is not you will need to check for power going to the combustion blower It should be a full current If...

Страница 21: ...move the two bolts that hold the auger bracket to the auger tube The auger bracket will now be able to be removed form the auger tube Remove the two bolts on the side of the auger tube to remove the l...

Страница 22: ...ating the unit be sure the hopper lid is closed so that the hopper safety switch will activate Check the wires leading from the hopper safety switch to the control panel and auger motor for secure con...

Страница 23: ...The Home Possible Causes Possible Remedies Unplug stove first when possible There is a leak in the vent pipe system Inspect all vent pipe connections Make sure they are sealed with RTV silicone that...

Страница 24: ...e caused a jam Loose wire or connector Check all wires and connectors that connector to the auger motor high limit switch and the Molex connector Bad control board If the fuse is good the wires and co...

Страница 25: ...l Burnpot holes are blocked Remove the burnpot and thoroughly clean it Blockage in air intake pipe Visually inspect the air intake pipe that leads into the burnpot for foreign material Combustion blow...

Страница 26: ...er Gasket 2 8 80630 Housing PCBA Controller 1 9 80631 Power Board 1 10 80491 Microswitch 1 11 80709 Room Blower 1 12 88347 High Temp Snapdisc Gasget 2 13 80601 High Temp Snapdisc Air 1 14 80599 T Disc...

Страница 27: ...2022 United States Stove Company 27 1 25A 250V FUSE 7 5A 250V FUSE CORRECT WRONG Ensure the wires are connected to the bottom two prongs of the hopper switch as shown WIRING DIAGRAM...

Страница 28: ...28 2022 United States Stove Company NOTES...

Страница 29: ...______ Engineer Name _____________________________________ License No _________________________________________ Company ___________________________________________ Telephone No _______________________...

Страница 30: ...ed States Stove Company 27 1 25A 250V Fusible 7 5A 250V Fusible CORRECT FAUX Assurez vous que les fils sont connect s aux deux broches inf rieures de l interrupteur de la tr mie comme illustr SCH MA D...

Страница 31: ...nde IR 1 4 69762 Pot de feu 1 5 892668 Couvercles de nettoyage des cendres 2 6 892199 Bo tier contr leur PCBA 1 7 80491 Commutateur de couvercle 1 8 80709 Sou eur de pi ce 1 9 80834 T Disc joint d air...

Страница 32: ...lot de granul s utilis s est peut tre de mauvaise qualit Si possible essayez une autre marque de granul s Essayez aussi une marque compos e d un autre type de bois r sineux plut t que feuillus Des boi...

Страница 33: ...de l arbre de la tari re et essayez de le faire fonctionner Si le moteur tourne c est l arbre qui est coinc sur quelque chose Si le moteur ne tourne pas il est d fectueux Tari re bloqu e Commencez par...

Страница 34: ...e tableau de commande n envoie pas de courant l allumeur V rifiez la tension qui arrive l allumeur lors du d marrage Ce doit tre la tension nominale Si la tension est inf rieure la valeur nominale v r...

Страница 35: ...rm pour permettre l interrupteur de s curit de la tr mie de s activer V rifiez le branchement des fils qui partent de l interrupteur de s curit de la tr mie jusqu au tableau de commande et au moteur d...

Страница 36: ...Retirez ensuite le moteur de la tari re en retirant la goupille de la tari re puis retirez les deux boulons qui fixent le support de tari re au tube de tari re Vous pouvez maintenant retirer le suppo...

Страница 37: ...Panne du ventilateur de combustion Lorsque le po le est en marche v rifiez si le ventilateur de combustion est en fonctionnement Sinon v rifiez l alimentation lectrique du ventilateur de combustion Ce...

Страница 38: ...e po le Si votre cran affiche nouveau E1 fermez la glissi re de 1 4 et recommencez Le ventilateur de convection surchauffe et d clenche l arr t de temp rature interne Enlevez la poussi re des bobinage...

Страница 39: ...propri taire sont sp cifiques votre appareil Lors de la commande de pi ces de rechange les informations contenues dans ce manuel vous aideront vous assurer que les bons articles sont command s Avant d...

Страница 40: ...N UTILISEZ PAS de nettoyants abrasifs N effectuez PAS le nettoyage lorsque la vitre est CHAUDE N essayez pas de faire fonctionner l appareil avec du verre bris Le verre de remplacement peut tre achet...

Страница 41: ...son de chauffage Pour nettoyer la chemin e d connecter l vacuation du po le CENDRES VOLANTES Elles s accumulent dans la portion horizontale du conduit d vacuation Bien qu elles ne soient pas combustib...

Страница 42: ...dans le pot de combustion pour liminer toute accumulation qui peut emp cher l air de se d placer travers le pot de combustion librement Echangeur de chaleur Il y a une plaque nettoyer des deux c t s d...

Страница 43: ...du po le tous les t moins de l cran s teignent et l cran deux chiffres affiche E3 en clignotant RECHARGE EN COMBUSTIBLE AVERTISSEMENT LA TR MIE ET LE COUVERCLE DU PO LE SONT CHAUDS PENDANT LE FONCTION...

Страница 44: ...de combustion ne contient pas de granul s N ouvrez PAS la porte de visualisation Il se peut que le registre doive tre ferm pendant le d marrage N ajoutez PAS de granul s dans le pot de combustion la...

Страница 45: ...particules L interdiction de la combustion de ces mat riaux n interdit pas l utilisation des d marreurs de feu fabriqu s partir de papier de carton de sciure de cire et substances similaires dans le...

Страница 46: ...eaux de production de chaleur changent progressivement sur le diagramme en barres passant du niveau 1 au niveau 5 de chauffage C Touche C F La touche C F fait passer l affichage deux chiffres des degr...

Страница 47: ...ers un tuyau de connecteur de 6 pouces les illustrations ci dessous ne sont que des exemples Veuillez con rmer tous les codes du b timent locaux ou ragulations ayant comp tence avant de demander un in...

Страница 48: ...tion de tuyau d au moins 3 pi 0 91 m doit tre ajout e avec un chapeau horizontal pour achever l installation Un support doit tre plac juste au dessous du chapeau de sortie ou raison d un support tous...

Страница 49: ...e conduit d vacuation pour po le granul s est con u pour tre d mont aux fins de nettoyage et doit tre v rifi plusieurs fois au cours de la saison de chauffage Le conduit d vacuation pour po le granul...

Страница 50: ...ou 101 mm et doit d passer d au moins 36 po 914 mm au dessus de la fa ti re de la maison mobile elle doit tre install e avec un pare feu de plafond et un chapeau anti pluie homologu s UL En cas de d p...

Страница 51: ...A Retour Cuisini re U S A 1 26 CAN 8 204 B C t po le U S A 6 153 CAN 8 204 C De l avant au po le U S A 6 153 CAN 8 204 D Retour Flue 2 51 D GAGEMENTS Votre po le granules a t test et r pertori pour un...

Страница 52: ...ASSAGE ET NE LE COINCEZ PAS SOUS LES MEUBLES ATTENTION ATTENTION LA COMBUSTION DU COMBUSTIBLE G N RE DU MONOXYDE DE CARBONE QUI PEUT S AV RER DANGEREUX POUR LA SANT EN L ABSENCE D UNE VENTILATION APPR...

Страница 53: ...bles comme illustr 2 D ballez les meilleurs contr les de montage et de veiller ce que le faisceau de c blage illustr est fix 3 Connecter les install s en usine faisceaux de c blage sur le panneau de c...

Страница 54: ...n date d inspection du syst me de ventilation existant ___________________________________________________________________ MISE EN SERVICE Confirmer l installation du tapis de foyer conform ment aux i...

Страница 55: ...uel d crit l installation et le fonctionnement du po le bois USSC 5710 XH Cet appareil de chauffage respecte les limites d mission de bois de berceau de l Environmental Protection Agency des tats Unis...

Страница 56: ...ion de ce radiateur Contactez les responsables locaux du b timent ou des pompiers pour conna tre les permis les restrictions et les exigences d installation dans votre r gion NE JAMAIS UTILISER CE PRO...

Отзывы: