User Configerable Settings
18
Filter Cycle 1 (‘FC-1’)
The Filter Cycle 1 setting allows you set the duration and start time for hye
cycle. Pressing ‘Temp Up’ will show the currently set cycle duration, which
can be set from 0 hours (no cycle) to 12 hours by pressing ‘Temp Up’ as
many times as needed to reach the desired setting. Pressing ‘Temp Down’
will then show the cycle’s start time, which can be set from 12 AM to 11 PM
by pressing ‘Temp Up’ as needed to reach the desired setting. The factory
default start time for the first daily filtration cycle is 6 AM.
Filter Cycle 2 (‘FC-2’)
The Filter Cycle 2 setting allows you set the duration and start time for hye
cycle. Pressing ‘Temp Up’ will show the currently set cycle duration, which
can be set from 0 hours (no cycle) to 12 hours by pressing ‘Temp Up’ as
many times as needed to reach the desired setting. Pressing ‘Temp Down’
will then show the cycle’s start time, which can be set from 12 AM to 11 PM
by pressing ‘Temp Up’ as needed to reach the desired setting. The factory
default start time for the first daily filtration cycle is 6 PM.
Filtration Purge (‘PURG’)
When the Purge Setting is turned ‘On’, the control will automatically purge
the plumbing of whatever components the system is programmed to
operate (on low speed where applicable) for 30 seconds each, starting a
minute after the beginning of each cycle. This serves to push any water
currently in those components’ plumbing back into the main body of water
for circulation and filtration.