background image

 

 

  

 

IP 20001

CAUTION:  THE UV CELL CONTAINED WITHIN THIS UNIT IS DESIGNED TO BE OPERATED WHILE 
THE COVER IS ON THE UNIT.  ANYTIME UV‐C LIGHT/RADIATION IS USED, EXPOSURE TO IT CAN 
CAUSE TEMPERORY EYE AND/OR SKIN IRRITATION IN VARYING DEGREES.   

1

 

CAPS‐Commuter Unit 

The CAPS‐Commuter is designed to help reduce sick commuter syndrome risks by reducing 
airborne microbes, contaminants, and odors, with a patent pending Photohydroionization ® 
(PHI) process.  The PHI cell is contained within the CAPS‐Commuter unit.  When the CAPS‐
Commuter system is in operation, the PHI Cell uses ‘Active Air’ with RGF PHI® Technology, an 
Advanced Oxidation Process to reduce airborne contaminants. 

 

 

2

 

CAPS‐Commuter Installation Procedure 

 

2.1

 

Hardware & Tools Required 

 

1.

 

¼” Hardware 

2.

 

Diagonal cutters 

3.

 

Wire strippers 

 

2.2

 

Unit installation 

 

1.

 

The unit should be mounted using the mounting points depicted in the Figure 1 below 
using ¼” hardware (not provided).  Dimensions of the bolt pattern can be found in 
Figure 2. 
 

Содержание 20001

Страница 1: ...IP 20001 Installation Procedure IP 20001 CAPS COMMUTER SERVICE MANUAL INSTALLATION INSTRUCTIONS 10 08 2020 REV 3...

Страница 2: ...3 2 CAPS Commuter Installation Procedure 3 2 1 Hardware Tools Required 3 2 2 Unit installation 3 3 CAPS Commuter UV PHI Cell Service Maintenance Procedure 6 3 1 Components Tools Required 6 3 2 Procedu...

Страница 3: ...s with a patent pending Photohydroionization PHI process The PHI cell is contained within the CAPS Commuter unit When the CAPS Commuter system is in operation the PHI Cell uses Active Air with RGF PHI...

Страница 4: ...4 IP 20001 Figure 1 CAPS COMMUTER INSTALLATION Figure 2 BOLT PATTERN REFERENCE DIMENSIONS...

Страница 5: ...that the unit is connected to should be switched by the ignition or something similar This will prevent the system from being left on accidentally causing the vehicle battery to die Use external wirin...

Страница 6: ...tinuing with this procedure ensure power to the unit has been disconnected 3 1 Components Tools Required 1 Replacement Cell United Safety P N 83G53043 NN 2 Replacement Install Date Label provided with...

Страница 7: ...6 UNIT COVER REMOVED 3 The UV PHI cell is now exposed as can be seen in Figure 7 By spreading the clamps that are holding the cell the cell can be removed See Figure 7 below Figure 7 BULB REMOVAL 4 W...

Страница 8: ...FROM PLUG 5 Using replacement cell installation and reassembly should happen in the reverse order NOTE Ensure that the pins on the cell line up with the connector properly before pushing together See...

Страница 9: ...6 After reassembly of the unit apply install date label Figure 10 onto the unit over the previously installed label Be sure to add the installation date of the new cell on the label Figure 10 INSTALL...

Страница 10: ...uded from this warranty This warranty also excludes any defect caused in whole or in part by the application of paints or metal finish to any part of the Warranted unit This warranty is provided direc...

Страница 11: ...aims can be made INSPECTION AND VERIFICATION The owner must provide access to each alleged defective Warranted Unit so that UNITED SAFETY s authorized representative can perform an on site inspection...

Страница 12: ...ials may be released Chemical Name CAS Number by weight Exposure Limits in Air mg cubic meter ACGIH TLV OSHA PEL Quartz Fused Silica 60676 86 0 75 90 0 1 0 1 Mercury 7439 97 6 0 1 0 025 0 1 ceiling Ti...

Страница 13: ...The major hazard from broken lamps is the possibility of sustaining glass cuts EFFECTS OF OVEREXPOSURE TO BROKEN LAMPS BY INHALATION INGESTION OR CONTACT WITH SKIN OR EYE Mercury Exposure to high con...

Страница 14: ...N FOR BROKEN LAMPS Ventilation Use adequate general and local exhaust ventilation to maintain exposure levels below the PEL or TLV limits If such ventilation is unavailable use respirators as specifie...

Отзывы: