MATERIAL SAFETY DATA SHEET 

Germicidal lamps are exempted from the requirements of the OSHA Hazard Communication Standard 
(29 CFR 1910.1200) because they are “articles.” The following information is provided as a courtesy to our customers. 

 

PRODUCT NAME: GERMICIDAL/UV LAMPS

 

 

 

Section I 

MANUFACTURER’S INFORMATION

 

 

 

Manufacturer’s Name & Address: 

 

RGF O

Systems, Inc. 

3875 Fiscal Court 

Telephone Number for Information: 561-848-1826 

West Palm Beach, Florida 33404 

Date Prepared: July 11, 2001  updated June 7, 2003 

 

 
 
 

Section II 

HAZARDOUS INGREDIENTS

 

 

 

THERE ARE NO KNOWN HEALTH HAZARDS FROM EXPOSURE TO LAMPS THAT ARE INTACT. 
If the lamp is broken, the following materials may be released: 

 

Chemical Name

 

CAS Number

 

% by weight

 

Exposure Limits in Air (mg/cubic meter)

 

 

 

 

ACGIH (TLV) 

OSHA (PEL) 

Quartz (Fused Silica) 

60676-86-0 

75-90 

0.1*** 

0.1*** 

Mercury* 

7439-97-6 

<0.1 

0.025 

0.1 (ceiling) 

Tin 

7440-31-5 

0-<1 

2.0 

2.0 

Lead 

7439-92-1 

0-<1 

0.5 

0.05 

Argon 

7440-37-1 

0-<1 

** 

None 

Neon 

7440-01-9 

0-<1 

** 

None 

Xenon 

7440-63-3 

0-<1

**

None 

 

*  This chemical is subject to the reporting requirements of Section 313 of Title III of the Superfund Amendments and 
Reauthorization Act of 1986 and 40 CRF Part 372. 

 

**   The  TLV  for  a  simple  asphyxiant  is  a  minimal  atmospheric  oxygen  content  of  18%  by  volume,  at  1  atmospheric 
pressure. 

 

*** When  quartz  tubing  is  heated  to  working  temperatures,  the  silica  vapors  given  off  condense  as  amorphous  silica. 
Amorphous silica has a TLV of 10 mg/cu.m. and a PEL of 6 mg/cu.m. 

 

 

 

Section III 

PHYSICAL/CHEMICAL CHARACTERISTICS

 

 

 

Not applicable to intact lamp. 

 

Содержание 20001

Страница 1: ...IP 20001 Installation Procedure IP 20001 CAPS COMMUTER SERVICE MANUAL INSTALLATION INSTRUCTIONS 10 08 2020 REV 3...

Страница 2: ...3 2 CAPS Commuter Installation Procedure 3 2 1 Hardware Tools Required 3 2 2 Unit installation 3 3 CAPS Commuter UV PHI Cell Service Maintenance Procedure 6 3 1 Components Tools Required 6 3 2 Procedu...

Страница 3: ...s with a patent pending Photohydroionization PHI process The PHI cell is contained within the CAPS Commuter unit When the CAPS Commuter system is in operation the PHI Cell uses Active Air with RGF PHI...

Страница 4: ...4 IP 20001 Figure 1 CAPS COMMUTER INSTALLATION Figure 2 BOLT PATTERN REFERENCE DIMENSIONS...

Страница 5: ...that the unit is connected to should be switched by the ignition or something similar This will prevent the system from being left on accidentally causing the vehicle battery to die Use external wirin...

Страница 6: ...tinuing with this procedure ensure power to the unit has been disconnected 3 1 Components Tools Required 1 Replacement Cell United Safety P N 83G53043 NN 2 Replacement Install Date Label provided with...

Страница 7: ...6 UNIT COVER REMOVED 3 The UV PHI cell is now exposed as can be seen in Figure 7 By spreading the clamps that are holding the cell the cell can be removed See Figure 7 below Figure 7 BULB REMOVAL 4 W...

Страница 8: ...FROM PLUG 5 Using replacement cell installation and reassembly should happen in the reverse order NOTE Ensure that the pins on the cell line up with the connector properly before pushing together See...

Страница 9: ...6 After reassembly of the unit apply install date label Figure 10 onto the unit over the previously installed label Be sure to add the installation date of the new cell on the label Figure 10 INSTALL...

Страница 10: ...uded from this warranty This warranty also excludes any defect caused in whole or in part by the application of paints or metal finish to any part of the Warranted unit This warranty is provided direc...

Страница 11: ...aims can be made INSPECTION AND VERIFICATION The owner must provide access to each alleged defective Warranted Unit so that UNITED SAFETY s authorized representative can perform an on site inspection...

Страница 12: ...ials may be released Chemical Name CAS Number by weight Exposure Limits in Air mg cubic meter ACGIH TLV OSHA PEL Quartz Fused Silica 60676 86 0 75 90 0 1 0 1 Mercury 7439 97 6 0 1 0 025 0 1 ceiling Ti...

Страница 13: ...The major hazard from broken lamps is the possibility of sustaining glass cuts EFFECTS OF OVEREXPOSURE TO BROKEN LAMPS BY INHALATION INGESTION OR CONTACT WITH SKIN OR EYE Mercury Exposure to high con...

Страница 14: ...N FOR BROKEN LAMPS Ventilation Use adequate general and local exhaust ventilation to maintain exposure levels below the PEL or TLV limits If such ventilation is unavailable use respirators as specifie...

Отзывы: