Section VII                                                   PROCEDURES FOR DISPOSAL OF LAMPS

 

 

 

If lamps are broken, ventilate area where breakage occurred. Clean up with mercury vacuum cleaner or other suitable means 
that avoid dust and mercury vapor generation. Take usual precautions for collection of broken glass. Clean up requires special 
care  due  to  mercury  droplet  proliferation.  Place  materials  in  closed  containers  to  avoid  generating  dust.  It  is  the 
responsibility of the generator to ensure proper classification of waste products. To that end, TCLP tests should be conducted 
on  all  waste  products  to  determine  the  ultimate  disposition  in  accordance  with  all  applicable  federal,  state  and  local 
regulations. 
 
 

 

Section VIII                  SPECIAL HANDLING INFORMATION FOR BROKEN LAMPS

 

 

 

Ventilation: Use adequate general and local exhaust ventilation to maintain exposure levels below the PEL or TLV limits. 
If such ventilation is unavailable, use respirators as specified below. 
Respiratory  Protection:  Use  appropriate  NIOSH  approved  respirator  if  airborne  dust  concentrations  exceed  the  PEL  or 
TLV 
limits. All appropriate requirements set forth in 29 CFR 1910.134 should be 
met. 
Eye Protection: OSHA specified safety glasses, goggles or face shield are recommended if lamps are being 
broken. Hygienic Practices: After handling broken lamps, wash thoroughly before eating, smoking or using 
toilet facilities. 

 
 

 

 

 

 

 

The information herein has been compiled from sources believed to be reliable and is accurate to the best of our knowledge. 
However,  RGF  cannot give any guarantees regarding  information from other sources, and expressly does not make any 
warranties, nor assumes any liability, for its use. 

 
 

 

 

Содержание 20001

Страница 1: ...IP 20001 Installation Procedure IP 20001 CAPS COMMUTER SERVICE MANUAL INSTALLATION INSTRUCTIONS 10 08 2020 REV 3...

Страница 2: ...3 2 CAPS Commuter Installation Procedure 3 2 1 Hardware Tools Required 3 2 2 Unit installation 3 3 CAPS Commuter UV PHI Cell Service Maintenance Procedure 6 3 1 Components Tools Required 6 3 2 Procedu...

Страница 3: ...s with a patent pending Photohydroionization PHI process The PHI cell is contained within the CAPS Commuter unit When the CAPS Commuter system is in operation the PHI Cell uses Active Air with RGF PHI...

Страница 4: ...4 IP 20001 Figure 1 CAPS COMMUTER INSTALLATION Figure 2 BOLT PATTERN REFERENCE DIMENSIONS...

Страница 5: ...that the unit is connected to should be switched by the ignition or something similar This will prevent the system from being left on accidentally causing the vehicle battery to die Use external wirin...

Страница 6: ...tinuing with this procedure ensure power to the unit has been disconnected 3 1 Components Tools Required 1 Replacement Cell United Safety P N 83G53043 NN 2 Replacement Install Date Label provided with...

Страница 7: ...6 UNIT COVER REMOVED 3 The UV PHI cell is now exposed as can be seen in Figure 7 By spreading the clamps that are holding the cell the cell can be removed See Figure 7 below Figure 7 BULB REMOVAL 4 W...

Страница 8: ...FROM PLUG 5 Using replacement cell installation and reassembly should happen in the reverse order NOTE Ensure that the pins on the cell line up with the connector properly before pushing together See...

Страница 9: ...6 After reassembly of the unit apply install date label Figure 10 onto the unit over the previously installed label Be sure to add the installation date of the new cell on the label Figure 10 INSTALL...

Страница 10: ...uded from this warranty This warranty also excludes any defect caused in whole or in part by the application of paints or metal finish to any part of the Warranted unit This warranty is provided direc...

Страница 11: ...aims can be made INSPECTION AND VERIFICATION The owner must provide access to each alleged defective Warranted Unit so that UNITED SAFETY s authorized representative can perform an on site inspection...

Страница 12: ...ials may be released Chemical Name CAS Number by weight Exposure Limits in Air mg cubic meter ACGIH TLV OSHA PEL Quartz Fused Silica 60676 86 0 75 90 0 1 0 1 Mercury 7439 97 6 0 1 0 025 0 1 ceiling Ti...

Страница 13: ...The major hazard from broken lamps is the possibility of sustaining glass cuts EFFECTS OF OVEREXPOSURE TO BROKEN LAMPS BY INHALATION INGESTION OR CONTACT WITH SKIN OR EYE Mercury Exposure to high con...

Страница 14: ...N FOR BROKEN LAMPS Ventilation Use adequate general and local exhaust ventilation to maintain exposure levels below the PEL or TLV limits If such ventilation is unavailable use respirators as specifie...

Отзывы: