background image

IM_1GSW-02

www.ueonline.com

12

Page

Warning Text

Texte d’advertissement

1

Misuse of this product may cause personal injury. These instructions 
must be thoroughly read and understood before unit is installed. 
See the product nameplate information for specific agency certifica-
tions applicable to your product. 

Une mauvaise utilisation de ce produit peut entraîner des blessures. Ces 
instructions doivent être soigneusement lues et comprises avant l’ appareil 
est installé. Voir l’information sur la plaque signalétique du produit pour les 
certifications d’agence spécifiques applicables.

1

Continuous operation should not exceed the designated over range 
pressure or working pressure range stated within the literature and 
on device nameplate. 

Le fonctionnement continu ne doit pas dépasser la pression de dépassement 
ou la plage de pression de fonctionnement indiquée dans la documentation 
et sur la plaque signalétique de l'appareil.

1

For pressure and local temperature models, always hold a wrench 
on the sensor housing hex when mounting the device. Do not 
tighten by turning the enclosure, as this will damage the connection 
between the sensor and housing. 

Pour tous les modèles de température et pression locaux, toujours tenir une 
clé sur l’hexagone du capteur pendant le montage de l’unité. Ne pas serrer 
en tournant l’enceinte, cela pourrait endommager la connexion entre le 
capteur et l’enceinte.

1

Install units where shock, vibration and temperature fluctuations are 

minimal.  Orient unit making sure that the electrical conduit connec-

tion is not facing up to prevent moisture from enternig enclosure.  

Do not mount unit in ambient temperatures exceeding the published 

limits.

Installez des unités là où les chocs, les vibrations et les fluctuations de 
température sont minimes. Orientez l’unité en vous assurant que la con-
nexion du conduit électrique n’est pas orientée vers le haut pour empêcher 
l’humidité de pénétrer dans le boîtier. N’installez pas l’unité à des tempéra-
tures ambiantes dépassant les limites publiées.

1

For differential pressure models (especially low range units), mount 
the sensor level to minimize any pressure reading offsets. The 
offset command may be used to zero the display (see page xx for 
additional information). 

Pour les modèles de pression différentielle (de pressions faibles), montez le 
niveau du capteur afin de minimiser tout décalage de lecture de pression. La 
commande décalée peut être utilisée pour mettre l'affichage à zéro (voir la 
page xx pour plus d'informations).

1

Never insert any object into the pressure sensor opening. Damage 
to the sensor will result, affecting accuracy. 

Ne jamais insérer un objet dans l’orifice du capteur de pression. Les dom-
mages à la membrane de capteur se traduira, à affecter la précision.

2

All models accept 8----50 VDC discrete power source directly from 
digital inputs of PLC’s, DCS and other low power DC loads.  The 
switched output maximum load rating is 0.1A.  Overloading the 
switch may cause failure.

Tous les modèles acceptent une source d’alimentation discrète 8 ---- 50 VDC 
directement à partir des entrées numériques des API, DCS et autres charges 
CC de faible puissance. La capacité de charge maximale de la sortie commu-
tée est de 0,1 A. Une surcharge du commutateur peut provoquer une panne.

2

The device shall be properly grounded in the end use application.

L’appareil doit être correctement mis à la terre dans l’application 
d’utilisation finale.

2

The input power shall be NEC/CEC Class 2, UL/CSA/IEC 60950 LPS 
or UL/CSA/IEC 61010 limited energy.

La puissance d’entrée doit être NEC / CEC Classe 2, UL / CSA / CEI 60950 
LPS ou UL / CSA / CEI 61010 à énergie limitée.

2

Field wiring must be rated 105°C minimum. For ambient tempera-
tures below -10°C, use suitable field wiring.

Câblage sur le terrain doit être évalué à 105°C minimum. Pour une tempéra-
ture ambiante inférieure à -10°C, utiliser le câblage approprié.

5

Use of this option may create a condition where the display may in-
dicate “0.00” when significant pressure or temperature (up to 10% 
of maximum range) exists in the system. Independent verification 
of the process variable should be done prior to maintenance on the 
system when “offset” appears on the display.

L'utilisation de cette option peut créer une condition dans laquelle l'écran 
peut indiquer «0,00» lorsqu'une pression ou une température significative 
(jusqu'à 10% de la plage maximale) existe dans le système. Une vérifica-
tion indépendante de la variable de processus doit être effectuée avant la 
maintenance du système lorsque «offset» apparaît à l'écran.

Warnings: French Translations

Содержание Excela 1GSWLL

Страница 1: ... TO PREVENT MOISTURE FROM ENTERING ENCLOSURE DO NOT MOUNT UNIT IN AMBIENT TEMPERATURES EXCEEDING PUBLISHED LIMITS FOR DIFFERENTIAL PRESSURE MODELS ESPECIALLY LOW RANGE UNITS MOUNT THE SENSOR LEVEL TO MINI MIZE ANY PRESSURE READING OFFSETS THE OFFSET COMMAND MAY BE USED TO ZERO THE DISPLAY SEE PAGE 5 FOR ADDITIONAL INFORMATION Excela is rated for both indoor and outdoor operation IP66 and Nema 4X w...

Страница 2: ...power supply use the test resistor supplied 1 8K Ω with the unit Loosen the four 4 Phillips head screws holding the faceplate to the enclosure Gently remove the faceplate module Dis connect the 8 wire connector from the faceplate to allow easy wiring Pass the wires through the conduit connector and connect to the terminal block You can wire the unit as a Normally Open or a Normally Closed switch T...

Страница 3: ...ax process values and the number of switch trips The dis play will revert back to the Process Display mode after scrolling Note While scrolling you can clear the values by pushing the right g arrow Pushing the right g button once the display will scroll setpoint Rise and Fall The display will revert back to the Process Display mode after scrolling ALARM CONDITION When the process goes beyond the R...

Страница 4: ...when switch trips PASSWRD Add your own 4 digit password for security OFST Allows low range value offset by 10 SPAN Change the high end by 10 LCH1 Latch switch output on rise needs to be reset manually PLUG PORT Monitors pressure fluctuations in process 1 min 1 hr 24 hr FILTER Smoothens transient pressure spikes Programmable from 1 4 to 2 seconds TRIP DELAY Like a switch timer delay trip up to 999 ...

Страница 5: ...mit Span 400 404 x 450 446 rounded LATCH MODE Similar to Manual Reset on mechanical switch The switch output can be configured to latch when the setpoint is reached on rising set point only Set Latching Mode In the Programming Mode set LCH1 to ON When the set point is crossed on increasing process parameter the switch will latch and will remain in the latched state until it is manually reset by th...

Страница 6: ...easure the voltage drop across the switch connected to the terminal block A properly functioning Excela electronic switch will exhibit the following voltage levels Model Voltage when switch is open Voltage when switch is closed 1GSWLL 8 50 VDC 5 VDC DISPLAY MODULE CALIBRATION The Serial on the module and the enclosure must match for proper operation Swapping modules among similar ranges would resu...

Страница 7: ...d clear the error and operate normally If error continues check for sensor damage due to over range exposure Overrange Process input is above 103 of range PRESSURE and TEMPERATURE above range value Automatic Reset when process variable returns to normal Underrange Process input is be low 1 25 of range PRESSURE and TEMPERATURE below range value Automatic Reset when process variable returns to norma...

Страница 8: ...RD CONFIRM PWORD PWORD CONFIRMED IF ON SET BLINKING DIGIT IF OFF DISCARD NEW PWORD POS NEG 8888 POS NEG ON OFF 8888 Both FILTER NOTE while scrolling pressing the right arrow will clear MAX MIN TRIPS values Advanced Menu OFF 1 4S 1 2S 1Sec 2Sec OFF and 1 4 Sec settings not available on temperature models TRIP DELAY ON OFF 8888 ON OFF SAVE CHNG NOTE Ifentriesareoutofrange ERR messagewillflashonscree...

Страница 9: ...IM_1GSW 02 www ueonline com 9 DIMENSIONAL DRAWINGS Model 1GSWLL Gauge Pressure Sensor Model 1GSWLL Differential Pressure Sensor ...

Страница 10: ...IM_1GSW 02 www ueonline com 10 Model 1GSWLL Temperature Model R Sensor Model 1GSWLL Temperature Model L Sensor ...

Страница 11: ...ight arrow button and continue to record new min max values 4 Press the right key to display the switch setpoints Verify that the setpoints are correct 5 To confirm process display on Excela connect calibration gauge to the Excela and verify that both displays match within tolerance If minor adjustment is needed up to 10 of range use the offset and span features within Excela s advanced programmin...

Страница 12: ...be used to zero the display see page xx for additional information Pour les modèles de pression différentielle de pressions faibles montez le niveau du capteur afin de minimiser tout décalage de lecture de pression La commande décalée peut être utilisée pour mettre l affichage à zéro voir la page xx pour plus d informations 1 Never insert any object into the pressure sensor opening Damage to the s...

Страница 13: ...sonnel Electrical ratings stated in literature and on nameplate must not be exceeded Overload on a switch can cause damage even on the first cycle Wire unit according to local and national electrical codes using wire size recommended in installation sheet Do not mount unit in ambient temp exceeding published limits LIMITED WARRANTY Seller warrants that the product hereby purchased is upon delivery...

Отзывы: