EN
www.uniteck.fr
17/34
CHARGING STEPS
UNICHARGE 1,5.12
1
TEST
Analyzes the state of charge of the battery.
2
BOOST CHARGE
Fast charging at maximum power (battery charged at 75-
80%).
3
EQUALISATION
Equalizes the charge on all the elements of the battery
(battery charged at 100%).
4
100%
Maintains battery charge at 100% (floating).
UNICHARGE 4.12 ET 8.12
1
TEST
Analyzes the state of charge of the battery.
2
REPAIR SB
(max. 4 hours)
Recovers sulphated batteries (prolonged deep discharge).
3
REPAIR LB
(max. 9 4 hours)
Analyzes the state of charge of the battery.
4
BOOST CHARGE
Fast charging at maximum power (battery charged at 75-
80%).
5
EQUALISATION
(4+5 = max. 36
hours)
Equalizes the charge on all the elements of the battery
(battery charged at 100%).
6
RECOND.
(UNICHARGE 8.12
only, max. 30min)
This step is operated when the RECOND mode is selected.
It enables stir the battery in order to avoid stratification.
7
CHARGE
DIAGNOSTIC
(1,5 seconds)
Checks that the battery is properly charged.
8
100%
(4 hours)
Maintains battery at 100% (floating).
9
LIFE+/STORAGE
Compensates the natural self-discharge of the battery, with
a pulse charge for longer battery lifespan.