UT-201

UNIVERSAL PROCESS INDICATOR & CONTROLLER

3

Flame Proof

 

K

 : -50~1200˚C

R

 : 0~1750˚C 

T

 : 0~400˚C

INPUT

RANGE

High scale / Low scale

Full range  as per input selection

General

Specificaion

Power Supply

110/240V AC, 50Hz, 12/24VDC [Optional on demand]

Power Consumption

4 Watts Maximum

Operating Ambient

Temp. : 0~50˚C, Humidity : Below 90% Non condensing

Input

T/C   

K, J, R, S, T, E

RTD 

Pt-100, Pt-1000, Cu-53 [2 wire, 3 wire]

Linear : 4 ~20mA DC, 0~20mA DC, 0 ~5 Amp AC

CURRENT [Analog]

VOLTAGE [Analog]

Linear : 0.5~2.5VDC, 1~5VDC, 0~10VDC

SPECIAL ON DEMAND

Linear : 0~75m/0~200mVDC, 0~100/200/300VDC

Indication

Display Indication

[Ch:1]

 : 0.56” 4 Digit

 [Ch:2]

: 0.56” 4 Digit, 2 set 7 Segment Red Displays.

Relay Status

Front Red LED for all Relay Alarm status

RTD 

Pt-100 : -50~400˚C
Linear All DC & AC : -1999~9999 Display

CURRENT [Analog]

VOLTAGE [Analog]

Linear All DC : -1999~9999 Display

SPECIAL ON DEMAND

Linear : -1999~9999 Display

T/C   

Accuracy

T/C   

+ 0.25% of Full Scale

RTD 

Class A

+ 0.1% of Full Scale

ANALOG [V & I]

SPECIAL ON DEMAND

+ 0.1% of Full Scale

Automatic Software based self compensation

Cold Junction Comp.

OPEN

” or “

OVER

” indication on display

Sensor Break Info.

AS per Input Range Table

Range Limits

>330 K for Voltage ,mV, and T/C,  100 R for current

Input Impedance

Status indication

Alarm modes

LEDs for Relay status & Communication

Low / High

Control Mode

On Off control

Dead Band controls 

High and Low Set point for level application

Relay / SSR            Max. : 2 Nos.[one for each channel]

Relay Output

SSR [Volt] Output               

Retransmission 

24VDC @ 20 mA ,12VDC @ 20 mA

Linear : 0~20/ 4~20 mA DC, 0~10 VDC

NO-C-NC Contacts , 5A@240 VAC Resistive, 2 Relays for each input

Other Output               

Transmitter Power Supply : Isolated 24VDC@60mA ,Max.

Output

Prog. parameters

Modbus RTU RS- 485/RS- 232 Communication 

Baud rate, Parity, Node address, Stop bit 

Protocols & method 

Max. Connections

Communication

Up to 128 Units

Programmable

Parameters

Display resolution

Setpoint / Hysteresis 

Relay logic

Full range  as per input selection

-1999 to 9999 fully configurable for each linear input

F.S. high & low alarm

Enclosure [If Reqd.]

FC-1

 [1-Compartment] OR 

FC-2

 [2-Comp.] 

IIA, IIB Exter. keys & Cable Entries

TECHNICAL SPECIFICATIONS

INPUT RANGE

J

 : -50~750˚C,

: 0~1750˚C, 

E

 : -50~400˚C,

2.3       Technical Specifications

Type of Input
[Ch-1 & Ch-2]

Содержание UT-201

Страница 1: ...utplindia in www Model No UT 201 DUAL CHANNEL UNIVERSAL PROCESS INDICATOR CONTROLLER INSTRUCTION MANUAL M 96 x 96 Flame Proof UT 201 M COM www utplindia in RL 2 RL 1 RL 4 RL 3 201 0 201 0 UT 201 M COM...

Страница 2: ...ts Applying 240V AC to a controller rated for 12 24VDC will severely damage the controller and is a fire and smoke hazard This controller is suitable for connection to 230 15 VAC 50 Hz or 12 24 VDC po...

Страница 3: ...GRAMMING 3 1 OPERATION INTERFACE 3 2 MODE ACCESS FLOW CHART 4 1 CONFIGURATION MODE 4 OPERATIONAL MODES 4 2 SETUP MODE 4 3 CALIBRATION MODE 4 4 CHANGE PASSWORD MODE 4 5 ERROR MESSAGE 5 COMMUNICATION MO...

Страница 4: ...can do any change in the mode Two different configuration levels provide easy access to parameters A4 digit security code perverts una uthorized changes Parameters can also be hidden to user to preve...

Страница 5: ...ND 0 1 of Full Scale Automatic Software based self compensation Cold Junction Comp OPEN or OVER indication on display Sensor Break Info AS per Input Range Table Range Limits 330 K for Voltage mV and T...

Страница 6: ...0 21 B A 4 20mA 0 20mA CURRENT mA 22 21 0 VDC 5 10 V VOLTAGE 21 22 23 3 WIRE 21 22 9 8 T mA Input TPS 24VDC Transmi er TRANSMITTER 2 WIRE 21 22 9 8 T mA Input TPS 24VDC Transmi er TRANSMITTER OUTPUT R...

Страница 7: ...ey allows enter into the Parameter moving from one parameter to another or saving a new value of parameter or a status of parameter Press to change set points in normal view UP KEY UP Key allows incre...

Страница 8: ...technically competent to do so Local regulations regarding electrical safety must be observed FAILURE TO COMPLY WITH THESE INSTRUCTION COULD BE RESULT IN SERIOUS INJURY OR DEATH Default Password will...

Страница 9: ...the applied Input Change the type Up by key Down by key Range Input Type is as follows TC 4 RTD1 0 20 4 20 10v Default Value 0000 tsp1 L on ALARM 1 RELAY ACTION Alarm Relay activation direction Values...

Страница 10: ...key Decrease by key dp2 0001 CHANNEL 2 DECIMAL POINT LINEAR INPUT Decimal Point resolution for display value Values Default Value 0001 NOTE Applicable for Analog Linear input only tsp3 tsp4 ALARM 3 4...

Страница 11: ...ue 000 2 Hys1 000 2 HYSTERESIS ALARM 1 Value Diff between On and Off of Relay 1 Scroll the digit by key Increase by key Range Values between 199 9 to 999 9 Default Value As per User s set Reqd ALARM S...

Страница 12: ...ration Span High at Span High PV Input NOTE After Span Cal press key for next para Apply High signal as per input press key Lop1 Lop2 CALIBRATION LOW RETRANSMISSION OUTPUT Calibration desired Low Outp...

Страница 13: ...ontroller Controller circuit failed Check the power connection Check the supply voltage 4 4 Change Password Mode 4 5 Error Message Range Values Parameter PAsS 0000 CHANGE PASSWORD MODE PASSWORD Passwo...

Страница 14: ...stem schematic DATA The system schematic for RS 485 Modbus protocol are as follows DATA Ethernet RS 232 or RS 485 CONVERTER D D 1 2 UT 201 Device 1 D D 1 2 D D 1 2 D D 1 2 RS 485 BUS ADD 1 ADD 2 ADD 3...

Страница 15: ......

Отзывы: