background image

 

52 

 

 

 

 

 

Code 128 / GS1-128 - ISBT 128 - transmit - Transmit concatenated codes or 

single codes 

 

<SW>435A02 

 

concatenate 

- IMPORTANT:   

  - Codes are not concatenated by default (default transmission   

      setting is "single codes only").   

  - You must select one of the "concatenated codes" transmission   

      options to send concatenated codes (see "transmit" section). 

 

Code 128 / GS1-128 - ISBT 128 - concatenate - Disable (only those specified 

by datasheet) (*) 

 

<SW>435B00 

 

Code 128 / GS1-128 - ISBT 128 - concatenate - Enable 

 

<SW>435B01 

 

GTIN processing 

- GTIN = Global Trade Item Number.   

- GTIN processing transmits GS1-128 as the 14 character GS1 Composite 

GTIN.   

- To use GTIN processing you must also activate the GS1-128 symbology.   

- IMPORTANT: when GS1-128 and GTIN processing are both activated it is not 

possible to read normal GS1-128 codes.

 

 

 

 

Содержание MS920

Страница 1: ...Wireless Pocket 2D Imager Scanner MS920 User Manual ...

Страница 2: ...e 6 CAPS NUM lock state 7 Data Transmission Settings 8 ISCP 8 Data format 8 Extended barcode data format 9 Transmission frame size TFS 9 Event notification 9 ISCP bar code 10 Preprocessing ISCP bar code 10 Unsuccessful decoding 11 Start of read session 11 End of read session 11 Start up 12 Trigger pulled 12 Trigger released 12 Wake up 13 Symbology identifier 13 Preamble 14 Postamble 14 Inter chara...

Страница 3: ...ission 22 Symbology identifier 23 User defined 23 Code mark 23 BPO 23 Symbology identifier 24 UDSI 24 code mark 24 check digit transmission 25 Canada Post 25 Symbology identifier 26 User defined 26 code mark 26 Codabar 26 Symbology identifier 27 User defined 27 code mark 27 Start Stop 27 CLSI library system 28 Check digit 29 Check digit verification 29 Check digit transmission 29 Barcode length 29...

Страница 4: ...its 35 Barcode length 35 Length mode 35 Set length L1 L2 and L3 36 Code 39 36 Symbology identifier 37 User defined 37 Code mark 37 Format 37 Start Stop 38 accepted characters 38 Check digit 39 check digit verification 39 check digit transmission 39 Barcode length 40 Length mode 40 Reading range 40 Reading tolerance 41 Unconventional Code 39 42 Special keys interpretation 42 Code 93 Code 93i 43 Sym...

Страница 5: ... 128 norms 48 Barcode length 49 Length mode 49 Reading tolerance 50 ISBT 128 50 transmit 51 concatenate 52 GTIN processing 52 Unconventional GS1 128 53 Reading range 53 DataMatrix 54 Symbology identifier 54 User defined 54 Code mark 54 Mirrored labels activation 55 Structured append 55 Header transmission 56 Dutch Post 56 Symbology identifier 56 User defined 56 Code mark 57 EAN UPC 57 UPC E1 58 Sy...

Страница 6: ...n 62 UPC A 62 UPC E 63 EAN 8 63 EAN 13 63 UPC number system 64 UPC A 64 UPC E 64 Re encoding UPC A UPC E EAN 8 65 ISBN 66 ISMN 66 ISSN 67 GTIN processing 67 Reading range 68 GS1 Composite 68 CC A B 68 CC C 69 EAN UPC composite message decoding 69 Symbology identifier 70 User defined 70 CC A B 70 CC C 70 Code mark 70 CC A B 70 CC C 71 Linear transmission only 71 ...

Страница 7: ... 75 Symbology identifier 75 User defined 75 Code mark 76 Intelligent mail 76 Symbology identifier 76 User defined 76 Code mark 77 Interleaved 2 of 5 77 Symbology identifier 77 User defined 77 Code mark 78 Check digit 78 Check digit verification 78 Check digit transmission 79 Barcode length 79 Length mode 79 Set length L1 L2 and L3 80 Reading tolerance 80 Japan Post 81 Symbology identifier 81 User ...

Страница 8: ...k 87 code 128 emulation 87 MSI Code 88 Symbology identifier 88 User defined 88 Code mark 88 Check digit 89 Check digit verification 89 Check digit transmission 89 Barcode length 89 Length mode 89 Set length L1 L2 and L3 90 Multicode 90 Activation 90 Bar code separator 91 Symbology identifier 91 User defined 91 Complete Multicode Compose 92 Incomplete Multicode Compose 92 Code mark 92 Complete Mult...

Страница 9: ...ser defined 97 Code mark 97 Check digit transmission 98 Unconventional stop 98 Barcode length 99 Length mode 99 Set length L1 L2 and L3 100 Postnet 100 Symbology identifier 100 User defined 100 Code mark 100 Check digit transmission 101 QR Code 101 Model 1 control 102 Inverse video 102 MicroQR activation 103 Symbology identifier 103 User defined 103 Code mark 104 Structured append 104 Header trans...

Страница 10: ...rk 110 Format 110 Barcode length 111 Length mode 111 TLC 39 112 Symbology identifier 112 User defined 112 Code mark 112 Linear transmission only 113 ECI security 113 6 Operating Settings 1 Pre defined trigger modes 1 Scanning Triggering 2 Triggering modes 2 Presentation threshold 4 Trigger timeout sec 4 Trigger activation 5 Software Trigger 6 Compose start character 7 Turn off after good read 7 Re...

Страница 11: ...14 Beeps LEDs 14 Note tone frequency 14 Power up beeps 15 Good read beeps 15 Number 15 Duration 16 Timing 17 Good read LED duration 17 Disable enable all good read signals 18 Error beep 19 Setup beep and LED 19 Multicode beeps 20 7 Configuration Modes And Utilities 1 Get version info 1 Get decode version info 1 Get all component versions 1 Necessary for upgrade of product firmware 2 Optical setup ...

Страница 12: ...hing is missing or damaged please contact your Unitech representative MS912 scanner Resource CD Quick Guide USB Charging Cable Hand Strap Battery Note 1 The scanner s default power off idle mode time is 3 minutes 2 Please charge scanner for at least 2 hours prior to initial use 2 Scanner Detail ...

Страница 13: ...he Start button and then on the Start menu clicking Devices and Printers 3 Click Add a device and then follow the instructions 4 Click the Bluetooth enabled device Unitech BT XXXXXX you want to add to your computer and then click Next If you don t see the device you want to add make sure the device is turned on and discoverable If you just turned on the device it may take Windows several seconds t...

Страница 14: ...s Switching Between HID and SPP Mode From SPP to HID If your MS920 is on SPP mode 1 Go to Devices and Printers under Control Panel remove the MS920 2 Use MS920 to scan the barcode HID 3 Undertake the procedure of searching new device and then select device Unitech BT XXXXXX and make pairing From HID to SPP If your MS920 is on SPP mode 1 Scan the barcode BT Un pair 2 Scan the barcode SPP 3 Undertak...

Страница 15: ... Inventory Mode Under Batch Mode 1 Scan Erase Inventory Buffer 2 Scan Erase 1 Scan Erase Batch Buffer 2 Scan Erase For detail information about barcodes please refers to section 5 Appendix Bar Code Configuration And Commands ...

Страница 16: ... 13 hours 1 scan 3 seconds Charge Time Fully charged in 4 hours Coverage 330 ft 100m class 1 Operating Temp 0 to 50 C 32 F to 122 F Symbologies 1D EAN UPC GS1 Databar limited expanded omni directional Code 39 Code 128 UCC EAN 128 ISBN ISBT Interleaved Matrix Industrial and Standard 2 of 5 Codabar Code 93 93i Code 11 MSI Plessey Telepen 2D Data Matrix PDF417 Micro PDF 417 Codablock Maxicode QR Azte...

Страница 17: ...gs only apply when using a the following interfaces USB Keyboard HID Keyboard Wedge HID Keyboard Bluetooth device profile Selection Select the keyboard for your application Keyboard settings only apply when using a the following interfaces USB Keyboard HID Keyboard Wedge HID Keyboard Bluetooth device profile Keyboard settings Selection North America SW 674000 Keyboard settings Selection French Win...

Страница 18: ...ection French Canadian Windows 95 98 SW 674003 Keyboard settings Selection French Canadian Windows XP 2000 SW 674004 Keyboard settings Selection Spanish Windows SW 674005 Keyboard settings Selection Italian Windows SW 674006 Keyboard settings Selection Swedish Windows SW 674007 ...

Страница 19: ...ttings Selection Japanese Windows SW 674009 Keyboard settings Selection Brazilian Portuguese Windows SW 67400A Keyboard settings Selection IBM NCR Terminals SW 67400B Keyboard settings Selection Czech QWERTY SW 67400C Keyboard settings Selection Slovakian QWERTY SW 67400D ...

Страница 20: ...W 67400E Keyboard settings Selection Swiss German SW 67400F Keyboard settings Selection Swiss French SW 674010 Keyboard settings Selection Danish SW 674011 Keyboard settings Selection Norwegian SW 674012 Keyboard settings Selection Hungarian SW 674013 ...

Страница 21: ...ection Portuguese SW 674015 Keyboard settings Selection Belgian French SW 674016 Extended ASCLL Keyboard settings only apply when using a the following interfaces USB Keyboard HID Keyboard Wedge HID Keyboard Bluetooth device profile Keyboard settings Extended ASCII Send codes w chars mapped to Windows 1252 SW 674201 ...

Страница 22: ...mbologies support the encoding of other functions keys such as PF1 and PageDown The special keys transmission settings allow you to transmit special keyboard combinations Ctrl char or Alt char as a single keyboard character Alt mode Keyboard settings only apply when using a the following interfaces USB Keyboard HID Keyboard Wedge HID Keyboard Bluetooth device profile Emulates PC AT keyboard Alt de...

Страница 23: ...set the CAPS NUM lock state The autodetect option allows the scanner to automatically detect the state of the CAPS and NUM lock Keyboard settings CAPS NUM state Autodetect SW 674500 Keyboard settings CAPS NUM state CAPS and NUM OFF SW 674501 Keyboard settings CAPS NUM state CAPS OFF NUM ON SW 674502 Keyboard settings CAPS NUM state CAPS ON NUM OFF SW 674503 ...

Страница 24: ...Protocol parameters ISCP ISCP SW 614001 Sending this parameter during online setup will lose the connection click Connect to reestablish the connection ISCP None SW 614000 Data format Barcode data is sent without a frame and no acknowledgement is necessary ISCP Data format Raw format SW 734000 Data is sent to the host in an ISCP frame ISCP Data format Packet format SW 734001 ...

Страница 25: ...tended barcode data format BCDEX SW 734E01 ISCP Data format Extended barcode data format DPS SW 734E02 Transmission frame size TFS Length of the longest frame that can be received by the host Value from 32 up to the maximum transmission frame size MTFS of the scanner ISCP Transmission frame size TFS 2048 SW 73800800 Event notification When active the scanner notifies the host when certain events t...

Страница 26: ...in the help menu in Easyset ISCP Event notification ISCP bar code Enable SW 734301 ISCP Event notification ISCP bar code Disable SW 734300 Preprocessing ISCP bar code When active the scanner informs the host of the following information after reading but BEFORE processing an ISCP bar code GID FID Parameter For information on the event frame received by the host see the ISCP online help available i...

Страница 27: ...decode has taken place ISCP Event notification Unsuccessful decoding Disable SW 734600 ISCP Event notification Unsuccessful decoding Enable SW 734601 Start of read session ISCP Event notification Start of read session Disable SW 734700 ISCP Event notification Start of read session Enable SW 734701 End of read session ISCP Event notification End of read session Disable SW 734800 ...

Страница 28: ...734900 ISCP Event notification Start up Enable SW 734901 Trigger pulled ISCP Event notification Trigger pulled Disable SW 734A00 ISCP Event notification Trigger pulled Enable SW 734A01 Trigger released ISCP Event notification Trigger released Disable SW 734B00 ISCP Event notification Trigger released Enable SW 734B01 ...

Страница 29: ...ent notification Wake up Enable SW 734501 ISCP Event notification Structured append Disable SW 735000 ISCP Event notification Structured append Enable SW 735001 Symbology identifier Symbology identifier Not transmitted SW 604000 Symbology identifier AIM format SW 604002 ...

Страница 30: ...mble None SW 60C00000 Postamble Postamble Carriage Return Line Feed SW 60C100020D0A Postamble None SW 60C10000 Inter character message delay Avoids dropping characters if transmitting decoded data too fast for the host system Inter character delay Inter character message delay Inter character delay 0 SW 60800000 ...

Страница 31: ...20 SW 60800014 Inter character message delay Inter character delay 30 SW 6080001E Inter character message delay Inter character delay 40 SW 60800028 Inter character message delay Inter character delay 50 SW 60800032 Inter message delay Value is in milliseconds Inter character message delay Inter message delay 0 SW 60810000 ...

Страница 32: ...032 Inter character message delay Inter message delay 80 SW 60810050 Inter character message delay Inter message delay 100 SW 60810064 Data editing IMPORTANT The data editing function is only available with STCDecode version 1 1 5 0 or later Your product can edit the data it receives before it transmits it to the host system Define up to 7 input scenarios to intercept the data you want to edit ...

Страница 33: ...ut mask 3 Define the actions editing you want to apply to this input Select a scenario Define the Action list editing for the selected scenario Make sure that the input scenarios you define actually correspond to incoming data conditions Correct input type all all input types Correct input length 0 all input lengths Correct input mask no value all input character combinations Activate scenarios Sc...

Страница 34: ...01 Scenario 3 Data editing Scenario 3 Disable SW 654200 Data editing Scenario 3 Enable SW 654201 Scenario 4 Data editing Scenario 4 Disable SW 654300 Data editing Scenario 4 Enable SW 654301 Scenario 5 Data editing Scenario 5 Disable SW 654400 ...

Страница 35: ... Scenario 5 Enable SW 654401 Scenario 6 Data editing Scenario 6 Disable SW 654500 Data editing Scenario 6 Enable SW 654501 Scenario 7 Data editing Scenario 7 Disable SW 654600 Data editing Scenario 7 Enable SW 654601 ...

Страница 36: ...Australian Post Disable SW 344000 Australian Post Enable SW 344001 Symbology identifier User defined Australian Post Symbology identifier User defined P3 SW 34C000025033 Code mark See Data transmission settings symbology identifier code mark to activate or deactivate code mark transmission Use the default value or compose your code mark for this symbology 1 character ...

Страница 37: ...sional matrix style symbology Can encode around 3000 characters using entire 256 byte ASCII Only available with models equipped with an area imager Aztec Disable SW 534000 Aztec Enable SW 534001 Aztec Runes Aztec Aztec Runes Disable SW 534200 Aztec Aztec Runes Enable SW 534201 ...

Страница 38: ...128 emulation Enable SW 534301 Structured append Aztec Structured append Disable SW 534100 Aztec Structured append Enable SW 534101 Header transmission Aztec Structured append Header transmission Disable SW 534600 Aztec Structured append Header transmission Enable SW 534601 ...

Страница 39: ...y 1 4 characters Aztec Symbology identifier User defined D3 SW 53C000024433 Code mark See Data transmission settings symbology identifier code mark to activate or deactivate code mark transmission Use the default value or compose your code mark for this symbology 1 character Aztec Symbology identifier Code mark SW 53482A BPO British Post Office symbology 4 State postal barcode only available with ...

Страница 40: ... activate or deactivate UDSI transmission Use the default value or compose your custom symbology identifier for this symbology 1 4 characters BPO Symbology identifier UDSI P2 SW 32C000025032 code mark See Data transmission settings symbology identifier code mark to activate or deactivate code mark transmission Use the default value or compose your code mark for this symbology 1 character See Data ...

Страница 41: ...r code mark SW 32482A check digit transmission BPO check digit transmission Enable SW 325401 BPO check digit transmission Disable SW 325400 Canada Post 4 state symbology Canada Post Disable SW 334000 Canada Post Enable SW 334001 ...

Страница 42: ...e or deactivate UDSI transmission Use the default value or compose your custom symbology identifier for this symbology 1 4 characters Canada Post Symbology identifier User defined P6 SW 33C000025036 code mark Canada Post Symbology identifier Code mark SW 33482A Codabar numerical symbology Codabar Disable SW 404000 Codabar Enable SW 404001 ...

Страница 43: ... for this symbology 1 4 characters Codabar Symbology identifier User defined B7 SW 40C000024237 code mark See Data transmission settings symbology identifier code mark to activate or deactivate code mark transmission Use the default value or compose your code mark for this symbology 1 character Codabar Symbology identifier Code mark D SW 404844 Start Stop Codabar Start Stop not transmitted SW 4058...

Страница 44: ...ary system Spaces inserted after characters 1 5 10 in the 14 character label used in the USA by libraries using the CLSI system Example 39990000192148 is transmitted as 3 9990 00019 2148 Start stop can be transmitted or not transmitted as required Codabar CLSI library system Disable SW 405900 Codabar CLSI library system Enable SW 405901 ...

Страница 45: ...git Codabar Check digit check digit transmission Disable SW 405400 Codabar Check digit check digit transmission Enable SW 405401 Barcode length Length mode Use the L1 as minimum length option if you know the minimum length of the codes in your application To optimize decoding performance and increase security select the same length as the minimum length in your application do not select a shorter ...

Страница 46: ...ength mode L1 as min L2 as max SW 405302 Set length L1 L2 and L3 Set barcode length L1 L2 and L3 according to the barcode length mode used Concatenation 2 adjacent Codabar codes scanned in a single sweep can be transmitted as a single message 1 Choose one of the transmission options to activate concatenation 2 Choose a concatenation mode option to indicate when you want adjacent codes to be concat...

Страница 47: ...smit concatenated codes SW 405A01 Concatenation mode Applies concatenation according to the desired start stop configuration Codabar Concatenation Concatenation mode No restriction SW 405B00 Codabar Concatenation Concatenation mode Second code start first code stop SW 405B01 Codabar Concatenation Concatenation mode American blood commission SW 405B02 ...

Страница 48: ... UDSI to activate or deactivate UDSI transmission Use the default value or compose your custom symbology identifier for this symbology 1 4 characters Codablock Codablock A Symbology identifier User defined K0 SW 4DC000024B30 code mark See Data transmission settings symbology identifier code mark to activate or deactivate code mark transmission Use the default value or compose your code mark for th...

Страница 49: ...ined User defined symbology identifier See Data transmission settings symbology identifier UDSI to activate or deactivate UDSI transmission Use the default value or compose your custom symbology identifier for this symbology 1 4 characters Codablock Codablock F Symbology identifier User defined K1 SW 4DC100024B31 code mark Codablock Codablock F Symbology identifier Code mark SW 4D492A ...

Страница 50: ...ransmission Use the default value or compose your custom symbology identifier for this symbology 1 4 characters Code 11 Symbology identifier User defined C1 SW 4AC000024331 Code mark See Data transmission settings symbology identifier code mark to activate or deactivate code mark transmission Use the default value or compose your code mark for this symbology 1 character Code 11 Symbology identifie...

Страница 51: ...um length option if you know the minimum length of the codes in your application To optimize decoding performance and increase security select the same length as the minimum length in your application do not select a shorter length Length mode L1 Codes with as many characters as specified by L1 and longer are read L2 and L3 are not used L2 Only codes that comply with the lengths specified by L1 L2...

Страница 52: ...arcode length Length mode L1 L2 L3 as fixed length SW 4A5301 Code 11 Barcode length Length mode L1 as min L2 as max SW 4A5302 Set length L1 L2 and L3 Set barcode length L1 L2 and L3 according to the barcode length mode used Code 39 Alphanumeric symbology Letter case not defined transmitted in upper case Format standard 43 characters default or full ASCII see format for lists Code 39 Disable SW 424...

Страница 53: ...your custom symbology identifier for this symbology 1 4 characters Code 39 Symbology identifier User defined B1 SW 42C000024231 Code mark See Data transmission settings symbology identifier code mark to activate or deactivate code mark transmission Use the default value or compose your code mark for this symbology 1 character Code 39 Symbology identifier Code mark SW 42482A Format Code 39 Format S...

Страница 54: ...e 39 Start Stop Not transmitted SW 425800 Code 39 Start Stop Transmitted SW 425801 accepted characters Code 39 Start Stop accepted characters only SW 425902 Code 39 Start Stop accepted characters only SW 425901 Code 39 Start Stop accepted characters and SW 425903 ...

Страница 55: ...heck digit verification Modulo 43 SW 424C01 Code 39 Check digit check digit verification French CIP SW 424C02 Code 39 Check digit check digit verification Italian CPI SW 424C03 check digit transmission You can chose to transmit or not transmitted the check digit Code 39 Check digit check digit transmission Disable SW 425400 ...

Страница 56: ...d L3 Codes at least the length specified by L1 and no longer than the maximum length specified by L2 are read L3 is not used Code 39 Barcode length Length mode L1 as Minimal length SW 425300 Code 39 Barcode length Length mode L1 L2 L3 as fixed length SW 425301 Code 39 Barcode length Length mode L1 as min L2 as max SW 425302 Reading range Applies a special algorithm for long distance reading defaul...

Страница 57: ...r codes High most permissive reads codes of variable quality Low least permissive only reads high quality codes that meet official Code 39 standards Quiet zone verification space before and after bar code to ensure correct decoding Code 39 Reading tolerance High SW 424F00 Code 39 Reading tolerance Medium SW 424F01 Code 39 Reading tolerance Low SW 424F02 ...

Страница 58: ... by using dual character combinations This function is also compatible with the Code 39 full ASCII format Example If you want to emulate the keystroke sequence Alt fx close Word file The bar code is encoded as Jfx J Code 39 full ASCII To read this code correctly you MUST activate the special keys interpretation function AND Code 39 full ASCII format Only for use with a USB or keyboard wedge cable ...

Страница 59: ...DUP S PF19 0S ESC T PF20 0T LINE FEED U PF21 0U RESET V PF22 0V CTRL W PF23 0W SHIFT X PF24 0X Code 39 Special keys interpretation Disable SW 425F00 Code 39 Special keys interpretation Enable SW 425F01 Code 93 Code 93i Code 93 Alphanumeric full ASCII symbology letter case defined Code 93i encompasses and extends Code 93 Alphanumeric full and extended ASCII all Unicode characters etc ...

Страница 60: ... See Data transmission settings symbology identifier UDSI to activate or deactivate UDSI transmission Use the default value or compose your custom symbology identifier for this symbology 1 4 characters Code 93 Code 93i Symbology identifier User defined B6 SW 41C000024236 Code mark Code 93 Code 93i Symbology identifier Code mark D SW 414844 ...

Страница 61: ... mode L1 Codes with as many characters as specified by L1 and longer are read L2 and L3 are not used L2 Only codes that comply with the lengths specified by L1 L2 and L3 will be read L3 Codes at least the length specified by L1 and no longer than the maximum length specified by L2 are read L3 is not used Code 93 Code 93i Barcode length Length mode L1 as Minimal length SW 415300 Code 93 Code 93i Ba...

Страница 62: ... GS1 128 Code 128 disable SW 434000 Code 128 GS1 128 GS1 128 enable SW 434201 Code 128 GS1 128 GS1 128 disable SW 434200 Symbology identifier User defined User defined symbology identifier See Data transmission settings symbology identifier UDSI to activate or deactivate UDSI transmission Use the default value or compose your custom symbology identifier for this symbology 1 4 characters ...

Страница 63: ...logy identifier code mark to activate or deactivate code mark transmission Use the default value or compose your code mark for this symbology 1 character Code 128 Code 128 GS1 128 Symbology identifier Code mark Code 128 D SW 434844 GS1 128 Code 128 GS1 128 Symbology identifier Code mark GS1 128 D SW 434944 GS1 128 identifier The C1 AIM identifier for GS1 128 is automatically added by default in fr...

Страница 64: ...character set C Code 128 GS1 128 CIP 128 French pharmaceutical codes Disable SW 434C00 Code 128 GS1 128 CIP 128 French pharmaceutical codes French CIP SW 434C01 FNC1 separator character GS1 128 norms Default GS function character ASCII 29 Used as separator when multiple identifiers and their fields are concatenated Example Useful for keyboard wedge interfaces where the GS character can not be tran...

Страница 65: ...racters to code alphanumerical data and numerical data if you can not read bar codes in your application this may be due to an unsuitable minimum length try entering a shorter length Length mode L1 Codes with as many characters as specified by L1 and longer are read L2 and L3 are not used L2 Only codes that comply with the lengths specified by L1 L2 and L3 will be read L3 Codes at least the length...

Страница 66: ... quality codes that meet official Code 39 standards Code 128 GS1 128 Reading tolerance High SW 434F00 Code 128 GS1 128 Reading tolerance Medium SW 434F01 Code 128 GS1 128 Reading tolerance Low SW 434F02 ISBT 128 International Society of Blood Transfusion Activating ISBT 128 deactivates Code 128 GS1 128 to avoid confusion with Code 128 GS1 128 You can re activate Code 128 or GS1 128 by using the co...

Страница 67: ...128 Disable SW 434100 Code 128 GS1 128 ISBT 128 active SW 434101434000434200 transmit IMPORTANT Codes are not concatenated by default default transmission setting is single codes only You must select one of the concatenated codes transmission options to send concatenated codes see transmit section Code 128 GS1 128 ISBT 128 transmit Disable SW 435A00 Code 128 GS1 128 ISBT 128 transmit Only transmit...

Страница 68: ...oncatenated codes see transmit section Code 128 GS1 128 ISBT 128 concatenate Disable only those specified by datasheet SW 435B00 Code 128 GS1 128 ISBT 128 concatenate Enable SW 435B01 GTIN processing GTIN Global Trade Item Number GTIN processing transmits GS1 128 as the 14 character GS1 Composite GTIN To use GTIN processing you must also activate the GS1 128 symbology IMPORTANT when GS1 128 and GT...

Страница 69: ...bled instructs the scanner to store data from the bar code containing the FNC2 and trnsmit it as a prefix to the date of the next bar code FNC4 ASCII extension disabled FNC4 automatically uses an extended ASCII char This option disables this function Reading range Applies a special algorithm for long distance reading default setting Use the normal setting if distance reading is not required Code 1...

Страница 70: ...fined User defined symbology identifier See Data transmission settings symbology identifier UDSI to activate or deactivate UDSI transmission Use the default value or compose your custom symbology identifier for this symbology 1 4 characters DataMatrix Symbology identifier User defined D0 SW 54C000024430 Code mark See Data transmission settings symbology identifier code mark to activate or deactiva...

Страница 71: ...els can be read as well as normal labels When disabled only normal labels can be read DataMatrix Mirrored labels activation disabled SW 544300 DataMatrix Mirrored labels activation enabled SW 544301 Structured append DataMatrix Structured append Disable SW 544500 DataMatrix Structured append Enable SW 544501 ...

Страница 72: ...code Only available with models equipped with an area imager Dutch Post Disable SW 364000 Dutch Post Enable SW 364001 Symbology identifier User defined User defined symbology identifier See Data transmission settings symbology identifier UDSI to activate or deactivate UDSI transmission Use the default value or compose your custom symbology identifier for this symbology 1 4 characters ...

Страница 73: ...identifier User defined P4 SW 36C000025034 Code mark Dutch Post Symbology identifier Code mark SW 36482A EAN UPC Numerical symbology EAN UPC UPC A enable SW 4B4001 EAN UPC UPC A disable SW 4B4000 EAN UPC UPC E enable SW 4B4101 ...

Страница 74: ...le SW 4B4201 EAN UPC EAN 8 disable SW 4B4200 EAN UPC EAN 13 enable SW 4B4301 EAN UPC EAN 13 disable SW 4B4300 UPC E1 Irregular UPC E with number system equal to 1 usually the first printed character UPC E must be active for UPC E1 to be taken into account ...

Страница 75: ...Data transmission settings symbology identifier UDSI to activate or deactivate UDSI transmission Use the default value or compose your custom symbology identifier for this symbology 1 4 characters UPC A EAN UPC Symbology identifier User defined UPC A A0 SW 4BC000024130 UPC E EAN UPC Symbology identifier User defined UPC E E0 SW 4BC100024530 ...

Страница 76: ...646 EAN 13 EAN UPC Symbology identifier User defined EAN 13 F SW 4BC3000146 Code mark UPC A EAN UPC Symbology identifier Code mark UPC A A SW 4B4841 UPC E EAN UPC Symbology identifier Code mark UPC E E SW 4B4945 EAN 8 EAN UPC Symbology identifier Code mark EAN 8 N SW 4B4A4E ...

Страница 77: ...F SW 4B4B46 Add on digits EAN UPC Add on digits not required but transmitted if read SW 4B5D00 EAN UPC Add on digits required and transmitted SW 4B5D01 add on 2 EAN UPC Add on digits add on 2 Disable SW 4B4500 EAN UPC Add on digits add on 2 Enable SW 4B4501 ...

Страница 78: ...urity level Used with add on not required but transmitted if read option Defines security level for add on 2 and add on 5 range 0 to 100 Higher security level lower decode rate EAN UPC Add on digits security level 10 SW 4B470A Check digit transmission UPC A EAN UPC Check digit transmission UPC A Enable SW 4B5401 ...

Страница 79: ...digit transmission UPC E Enable SW 4B5501 EAN UPC Check digit transmission UPC E Disable SW 4B5500 EAN 8 EAN UPC Check digit transmission EAN 8 Enable SW 4B5601 EAN UPC Check digit transmission EAN 8 Disable SW 4B5600 EAN 13 EAN UPC Check digit transmission EAN 13 Enable SW 4B5701 ...

Страница 80: ...Disable SW 4B5700 UPC number system UPC A EAN UPC UPC number system UPC A Enable SW 4B5801 EAN UPC UPC number system UPC A Disable SW 4B5800 UPC E EAN UPC UPC number system UPC E Enable SW 4B5901 EAN UPC UPC number system UPC E Disable SW 4B5900 ...

Страница 81: ...transmitted number system equal to 0 To transmit the additional leading character country code select the UPC A transmitted as EAN 13 option EAN UPC Re encoding UPC A UPC E EAN 8 UPC A transmitted as EAN 13 SW 4B5A01 EAN UPC Re encoding UPC A UPC E EAN 8 UPC A transmitted as UPC A SW 4B5A00 EAN UPC Re encoding UPC A UPC E EAN 8 UPC E transmitted as UPC E SW 4B5B00 EAN UPC Re encoding UPC A UPC E E...

Страница 82: ...onal Standard Book Number EAN 13 code the first 3 characters 978 or 979 except for 9790 are ignored and the checksum 0 9 X is calculated on the remaining characters EAN UPC ISBN Disable SW 4B4400 EAN UPC ISBN Enable SW 4B4401 ISMN International Standard Music Number EAN 13 code starting with 9790 the first 3 characters 979 are ignored and the first 0 is converted to M ...

Страница 83: ...977 are ignored and the ISBN checksum 0 9 X is calculated on the remaining characters EAN UPC ISSN Disable SW 4B6200 EAN UPC ISSN Enable SW 4B6201 GTIN processing GTIN Global Trade Item Number GTIN processing transmits EAN UPC as the 14 character GS1 Composite GTIN To use GTIN processing you must also activate the desired EAN UPC symbologies ...

Страница 84: ...01 Reading range Applies a special algorithm for long distance reading default setting Use the normal setting if distance reading is not required EAN UPC Reading range Normal SW 4B4D00 EAN UPC Reading range Extended SW 4B4D01 GS1 Composite CC A B GS1 Composite CC A B Disable SW 564000 ...

Страница 85: ...0 GS1 Composite CC C Enable SW 564101 EAN UPC composite message decoding Only applied to composite codes based on EAN UPC GS1 Composite EAN UPC composite message decoding Autodiscriminate imager only SW 565E02 GS1 Composite EAN UPC composite message decoding Always linked SW 565E01 ...

Страница 86: ...A B G0 SW 56C000024730 CC C GS1 Composite Symbology identifier User defined CC C G1 SW 56C100024731 Code mark See Data transmission settings symbology identifier code mark to activate or deactivate code mark transmission Use the default value or compose your code mark for this symbology 1 character CC A B GS1 Composite Symbology identifier Code mark CC A B SW 56482A ...

Страница 87: ...Allows you to decide to only transmit the linear code GS1 Composite Linear transmission only Disable SW 564400 GS1 Composite Linear transmission only Enable SW 564401 Unconventional When enabled the AIM identifier is always removed GS1 Composite Unconventional Disabled SW 564500 GS1 Composite Unconventional Enabled SW 564501 ...

Страница 88: ...ectional Enable SW 4F4001 GS1 DataBar RSS Omni directional Disable SW 4F4000 Symbology identifier User defined User defined symbology identifier See Data transmission settings symbology identifier UDSI to activate or deactivate UDSI transmission Use the default value or compose your custom symbology identifier for this symbology 1 4 characters GS1 DataBar RSS Omni directional Symbology identifier ...

Страница 89: ...isable SW 4F4100 Symbology identifier User defined User defined symbology identifier See Data transmission settings symbology identifier UDSI to activate or deactivate UDSI transmission Use the default value or compose your custom symbology identifier for this symbology 1 4 characters GS1 DataBar RSS Limited Symbology identifier User defined C4 SW 4FC100024334 ...

Страница 90: ...ble SW 4F4200 Symbology identifier User defined User defined symbology identifier See Data transmission settings symbology identifier UDSI to activate or deactivate UDSI transmission Use the default value or compose your custom symbology identifier for this symbology 1 4 characters GS1 DataBar RSS Expanded Symbology identifier User defined C5 SW 4FC200024335 ...

Страница 91: ...mbology identifier Code mark SW 4F4A2A Infomail Infomail Disable SW 394000 Infomail Enable SW 394001 Symbology identifier User defined User defined symbology identifier See Data transmission settings symbology identifier UDSI to activate or deactivate UDSI transmission Use the default value or compose your custom symbology identifier for this symbology 1 4 characters Infomail Symbology identifier ...

Страница 92: ...mark SW 39482A Intelligent mail Intelligent mail Disable SW 3A4000 Intelligent mail Enable SW 3A4001 Symbology identifier User defined User defined symbology identifier See Data transmission settings symbology identifier UDSI to activate or deactivate UDSI transmission Use the default value or compose your custom symbology identifier for this symbology 1 4 characters Intelligent mail Symbology ide...

Страница 93: ...is symbology 1 character Intelligent mail Symbology identifier Code mark SW 3A482A Interleaved 2 of 5 Numerical symbology For GTIN compatibility set barcode length to one fixed length of 14 characters Interleaved 2 of 5 Disable SW 444000 Interleaved 2 of 5 Enable SW 444001 Symbology identifier User defined Interleaved 2 of 5 Symbology identifier User defined B2 SW 44C000024232 ...

Страница 94: ...ode mark I SW 444849 Check digit Especially recommended for variable length Interleaved 2 of 5 and if consecutive same read data validation data decoding security parameters is not activated Check digit verification Interleaved 2 of 5 Check digit Check digit verification Disable SW 444C00 Interleaved 2 of 5 Check digit Check digit verification Modulo 10 SW 444C01 Interleaved 2 of 5 Check digit Che...

Страница 95: ...ved 2 of 5 always encodes an even number of characters For codes with an odd number of characters you can add a last character printed as 5 narrow bars not transmitted For GTIN compatibility set barcode length to one fixed length of 14 characters compose 1 or 2 or 3 fixed lengths provides the best performance and security if the codes in your application have fixed lengths recommended minimum leng...

Страница 96: ...ed length SW 445301 Interleaved 2 of 5 Barcode length Length mode L1 as min L2 as max SW 445302 Set length L1 L2 and L3 Set barcode length L1 L2 and L3 according to the barcode length mode used Reading tolerance Sets the tolerance level for reading hard to read bar codes High most permissive reads codes of variable quality Low least permissive only reads high quality codes that meet official Code ...

Страница 97: ... Post Disable SW 354000 Japan Post Enable SW 354001 Symbology identifier User defined User defined symbology identifier See Data transmission settings symbology identifier UDSI to activate or deactivate UDSI transmission Use the default value or compose your custom symbology identifier for this symbology 1 4 characters Japan Post Symbology identifier User defined P5 SW 35C000025035 ...

Страница 98: ...alue or compose your Code mark for this symbology 1 character Japan Post Symbology identifier Code mark SW 35482A Check digit transmission Japan Post Check digit transmission Enable SW 355401 Japan Post Check digit transmission Disable SW 355400 Matrix 2 of 5 Numerical symbology Matrix 2 of 5 Disable SW 454000 Matrix 2 of 5 Enable SW 454001 ...

Страница 99: ...racters Matrix 2 of 5 Symbology identifier User defined B4 SW 45C000024234 Code mark See Data transmission settings symbology identifier Code mark to activate or deactivate Code mark transmission Use the default value or compose your Code mark for this symbology 1 character Matrix 2 of 5 Symbology identifier Code mark D SW 454844 Matrix stop start char Matrix 2 of 5 Matrix stop start char Regular ...

Страница 100: ...55301 Matrix 2 of 5 Barcode length Length mode L1 as min L2 as max SW 455302 Set length L1 L2 and L3 Set barcode length L1 L2 and L3 according to the barcode length mode used MatrixCode Two dimensional alphanumerical symbology used by UPS Only available with models equipped with an area imager MaxiCode Disable SW 524000 MaxiCode Enable SW 524001 ...

Страница 101: ...r this symbology 1 4 characters MaxiCode Symbology identifier User defined D2 SW 52C000024432 Code mark See Data transmission settings symbology identifier Code mark to activate or deactivate Code mark transmission Use the default value or compose your Code mark for this symbology 1 character MaxiCode Symbology identifier Codemark SW 52482A Mode 0 This mode is obsolete We do not recommend using th...

Страница 102: ... Header Extended Mode 2 3 like SW 524201 MicroPDF417 Two dimensional symbology Alphanumeric full ASCII symbology letter case defined It is highly recommended to select stacked codes in sensor optimization see Operating settings read optimization MicroPDF417 Disable SW 4C4200 MicroPDF417 Enable SW 4C4201 ...

Страница 103: ...bology 1 4 characters MicroPDF417 Symbology identifier User defined C8 SW 4CC100024338 Code mark MicroPDF417 Symbology identifier Code mark SW 4C492A code 128 emulation When active and reading a MicroPDF code containing a special flag the scanner transmits the Code 128 AIM symbology identifier instead of the MicroPDF symbology identifier C instead of L MicroPDF417 Code 128 emulation Disable SW 4C4...

Страница 104: ...fier See Data transmission settings symbology identifier UDSI to activate or deactivate UDSI transmission Use the default value or compose your custom symbology identifier for this symbology 1 4 characters MSI Code Symbology identifier User defined B8 SW 46C000024238 Code mark MSI Code Symbology identifier Code mark D SW 464844 ...

Страница 105: ...ode Check digit Check digit verification Double Modulo 10 SW 464C02 Check digit transmission MSI Code Check digit Check digit transmission Enable SW 465401 MSI Code Check digit Check digit transmission Disable SW 465400 Barcode length Length mode MSI Code Barcode length Length mode L1 as Minimal length SW 465300 ...

Страница 106: ...ansmit them all at once Follow these steps to setup the Multicode function 1 Activate the Multicode function 2 Select the number of bar codes to be included the Multicode 3 Define which bar codes are part of the Multicode by specifying the bar code ID length and or mask 4 Define a separator to be used between bar codes 5 Define the Multicode transmission parameters 6 Define symbology identifiers f...

Страница 107: ...de Bar code separator SW 59D200023C3E Symbology identifier User defined User defined symbology identifier See Data transmission settings symbology identifier UDSI to activate or deactivate UDSI transmission Use the default value or compose your custom symbology identifier for this symbology 1 4 characters Multicode Symbology identifier User defined Complete Multicode default UDM0 SW 59D0000455444D...

Страница 108: ...activate or deactivate Code mark transmission Use the default value or compose your Code mark for this symbology 1 character Multicode Symbology identifier Code mark Complete Multicode default SW 59482A Complete Multicode Compose Multicode Symbology identifier Code mark Incomplete Multicode default SW 59492A Incomplete transmission When active an Incomplete Multicode is transmitted If not active I...

Страница 109: ...ut starts after the last bar code is read Value is in milliseconds Incomplete decode event When active an Incomplete decode event is sent by the host if the trigger is deactivated until all codes in the Multicode are read Multicode Incomplete decode event Disable SW 594300 Multicode Incomplete decode event Enable SW 594301 PDF417 Two dimensional symbology Alphanumeric full ASCII symbology letter c...

Страница 110: ...mission Use the default value or compose your custom symbology identifier for this symbology 1 4 characters PDF417 Symbology identifier User defined C7 SW 4CC000024337 Code mark See Data transmission settings symbology identifier Code mark to activate or deactivate Code mark transmission Use the default value or compose your Code mark for this symbology 1 character PDF417 Symbology identifier Code...

Страница 111: ...ured append Enable SW 4C4101 Header transmission PDF417 Structured append Header transmission Disable SW 4C5800 PDF417 Structured append Header transmission Enable SW 4C5801 Planet Postal symbology Only available with models equipped with an area imager Planet Disable SW 314000 ...

Страница 112: ...om symbology identifier for this symbology 1 4 characters Planet Symbology identifier User defined P1 SW 31C000025031 Code mark See Data transmission settings symbology identifier Code mark to activate or deactivate Code mark transmission Use the default value or compose your Code mark for this symbology 1 character Planet Symbology identifier Code mark SW 31482A Check digit transmission Planet Ch...

Страница 113: ...ology identifier UDSI to activate or deactivate UDSI transmission Use the default value or compose your custom symbology identifier for this symbology 1 4 characters Plessey Code Symbology identifier User defined C2 SW 47C000024332 Code mark See Data transmission settings symbology identifier Code mark to activate or deactivate Code mark transmission Use the default value or compose your Code mark...

Страница 114: ...4 Check digit transmission Plessey Code Check digit transmission Disable SW 475400 Plessey Code Check digit transmission Enable SW 475401 Unconventional stop Plessey Code Unconventional stop Disable SW 474300 Plessey Code Unconventional stop Enable SW 474301 ...

Страница 115: ...aximum length possible 25 characters Length mode L1 Codes with as many characters as specified by L1 and longer are read L2 and L3 are not used L2 Only codes that comply with the lengths specified by L1 L2 and L3 will be read L3 Codes at least the length specified by L1 and no longer than the maximum length specified by L2 are read L3 is not used Plessey Code Barcode length Length mode L1 as Minim...

Страница 116: ...UDSI to activate or deactivate UDSI transmission Use the default value or compose your custom symbology identifier for this symbology 1 4 characters Postnet Symbology identifier User defined P0 SW 30C000025030 Code mark See Data transmission settings symbology identifier Code mark to activate or deactivate Code mark transmission Use the default value or compose your Code mark for this symbology 1 ...

Страница 117: ...Code Two dimensional matrix symbology Only available with models equipped with an area imager Can encode up to 2509 numeric or 1520 alphanumeric characters Offers three levels of error detection Activating QR Code activates Model 2 Use the Model 1Control activation if you are using Model 1 not supported by all scanners Negative image QR Code not supported QR Code Disable SW 554000 ...

Страница 118: ...control Enable SW 554101 Inverse video Normal used for decoding black bar codes printed on white background Inverse used for decoding white bar codes printed on black background Automatic used to decode both types of bar codes QR Code Inverse video Normal SW 554200 QR Code Inverse video Inverse SW 554201 ...

Страница 119: ...le SW 554401 Symbology identifier User defined User defined symbology identifier See Data transmission settings symbology identifier UDSI to activate or deactivate UDSI transmission Use the default value or compose your custom symbology identifier for this symbology 1 4 characters QR Code Symbology identifier User defined D1 SW 55C000024431 ...

Страница 120: ...ompose your Code mark for this symbology 1 character QR Code Symbology identifier Code mark SW 55482A Structured append QR Code Structured append Disable SW 554500 QR Code Structured append Enable SW 554501 Header transmission QR Code Structured append Header transmission Disable SW 554600 QR Code Structured append Header transmission Enable SW 554601 ...

Страница 121: ...ier See Data transmission settings symbology identifier UDSI to activate or deactivate UDSI transmission Use the default value or compose your custom symbology identifier for this symbology 1 4 characters Standard 2 of 5 Symbology identifier User defined B5 SW 48C000024235 Code mark See Data transmission settings symbology identifier Code mark to activate or deactivate Code mark transmission Use t...

Страница 122: ...mat Identicon 6 start stop bars SW 485800 Standard 2 of 5 Format Computer Identics 4 start stop bars SW 485801 Check digit Check digit verification Standard 2 of 5 Check digit Check digit verification Disable SW 484C00 Standard 2 of 5 Check digit Check digit verification Modulo 10 SW 484C01 ...

Страница 123: ...nimum length in your application do not select a shorter length Length barcode data Check digit Minimum length possible 3 characters compose 1 or 2 or 3 fixed lengths provides the best performance and security if the codes in your application have fixed lengths Length mode L1 Codes with as many characters as specified by L1 and longer are read L2 and L3 are not used L2 Only codes that comply with ...

Страница 124: ...fixed length SW 485301 Standard 2 of 5 Barcode length Length mode L1 as min L2 as max SW 485302 Sweden Post Sweden Post Disable SW 374000 Sweden Post Enable SW 374001 Symbology identifier User defined User defined symbology identifier See Data transmission settings symbology identifier UDSI to activate or deactivate UDSI transmission ...

Страница 125: ...er defined P7 SW 37C000025037 Code mark See Data transmission settings symbology identifier Code mark to activate or deactivate Code mark transmission Use the default value or compose your Code mark for this symbology 1 character Sweden Post Symbology identifier Code mark SW 37482A Telepen Telepen Disable SW 494000 Telepen Enable SW 494001 ...

Страница 126: ...y identifier for this symbology 1 4 characters Telepen Symbology identifier User defined C6 SW 49C000024336 Code mark See Data transmission settings symbology identifier Code mark to activate or deactivate Code mark transmission Use the default value or compose your Code mark for this symbology 1 character Telepen Symbology identifier Code mark SW 49482A Format Telepen Format Ascii SW 495800 Telep...

Страница 127: ...aracter Length mode L1 Codes with as many characters as specified by L1 and longer are read L2 and L3 are not used L2 Only codes that comply with the lengths specified by L1 L2 and L3 will be read L3 Codes at least the length specified by L1 and no longer than the maximum length specified by L2 are read L3 is not used Telepen Barcode length Length mode L1 as Minimal length SW 495300 Telepen Barcod...

Страница 128: ...fier See Data transmission settings symbology identifier UDSI to activate or deactivate UDSI transmission Use the default value or compose your custom symbology identifier for this symbology 1 4 characters TLC 39 Symbology identifier User defined H0 SW 4EC000024830 Code mark See Data transmission settings symbology identifier Code mark to activate or deactivate Code mark transmission Use the defau...

Страница 129: ...transmission only TLC 39 Linear transmission only Disable SW 4E4400 TLC 39 Linear transmission only Enable SW 4E4401 ECI security Used to differentiate between TLC 39 and standard Code 39 Higher security level lower decode rate TLC 39 ECI security 10 SW 4E470A ...

Страница 130: ...urns the aimer illumination and decoding on If no decode second pull and release turns the aimer illumination and decoding off Pre defined trigger modes Toggle CCMD 405100 One pull turns on the aimer illumination and decoding If not decode aimer illumination and decoding turn off when the trigger is released Pre defined trigger modes Level CCMD 405101 One pull turns on the aimer only When the trig...

Страница 131: ...line is activated trigger pressed and off when the trigger line is deactivated trigger released Scanning Triggering Triggering modes Level SW 704001 Lighting and decoding are on when the trigger line is activated trigger pressed and stay on until a period of inactivity lasting the time specified by the trigger timeout After the timeout lighting and decoding are turned off Scanning Triggering Trigg...

Страница 132: ... to Flashing 1D models or Presentation 2D models At power up the scanner is in Flashing or Presentation trigger mode no need to activate the trigger line You can put a bar code in front of the scanner and it will be scanned To switch to Level activate the trigger line press the trigger You can scan bar codes by pulling the trigger When in Level trigger mode after a period of inactivity lasting the...

Страница 133: ... functions as if it were in Level mode Only available with 2D models Scanning Triggering Triggering modes Presentation SW 704006 Presentation threshold Only available on 2D models Use this setting when in Presentation Triggering mode to regulate how sensitive the imager is to movement which automatically wakes up the scanner The higher the value the stronger the movement is needed to wake up the s...

Страница 134: ...P terminal or sending an ISCP command Hardware and emulated triggers are disabled The only way to turn the imager on is by sending a decode on decode off control command 20 40 Scanning Triggering Trigger activation Disabled SW 704100 Hardware trigger ONLY is enabled Scanning Triggering Trigger activation Hardware trigger enabled SW 704101 Emulated trigger ONLY is enabled The trigger can only be ac...

Страница 135: ...ers received from the host system This option is NOT compatible with ISCP Scanning Triggering Software Trigger Disable SW 704200 Start read character default STX Stop read character default ETX This option is NOT compatible with ISCP Scanning Triggering Software Trigger Enable SW 704201 Scanning Triggering Software Trigger start character STX 02h SW 704302 ...

Страница 136: ...s Level Pulse Autostand Standard Aim NOTE this parameter is NOT used with continuous and flashing modes Scanning Triggering Turn off after good read Enable SW 704601 Scanning Triggering Turn off after good read Disable SW 704600 Retrigger delay Only valid if Turn off after good read is disabled This setting is a time delay in which the scanner turns off after a good read When the delay is done the...

Страница 137: ...tand Toggle NOTE In Toggle trigger mode one pull aim one pull read does not work as stated Instead one pull turns on the aimer only When the trigger is released decoding begins If no decode second pull turns aimer and decoding off Scanning Triggering Aimer mode Typical aimer SW 704500 Scanning Triggering Aimer mode One pull aim and read SW 704501 Scanning Triggering Aimer mode One pull aim second ...

Страница 138: ... and second pull If you wait longer than the duration before the second pull the cycle starts over with the aiming beam Scanning Triggering Aimer mode Duration ms 500 SW 708101F4 Scanning Triggering Aimer mode Duration ms 1200 SW 708104B0 Bad read message Activation Sends a message to the host if the read is unsuccessful Scanning Triggering Bad read message Activation Disable SW 604100 Scanning Tr...

Страница 139: ...gnore stand detect enable SW 704A01 Double scan prevention When enabled pulling the trigger a second time does not start a new reading session unless the timeout has expired This prevents the user from accidentally scanning the same bar code twice Use the Timeout between identical consecutive codes located in Data decoding security to set the timeout Note The default value of the timeout is not su...

Страница 140: ...an be modified individually Use medium and high security levels for poor quality bar codes or critical applications Increasing the security level reduces the reading speed Auto read count before transmission 300 ms between identical consecutive codes No timeout between different consecutive codes Data decoding security Predefined security levels Normal SW 7140007180012C71810000 2 consecutive same ...

Страница 141: ...only transmitted after repeated reads give the same result Data decoding security Consecutive same read data validation Auto read count before transmission SW 714000 Data decoding security Consecutive same read data validation Single read before transmission SW 714001 Timeout between different consecutive codes ms Prevents unwanted reading of other bar codes on the same label Data decoding securit...

Страница 142: ...4100 Data decoding security Center decoding Activation Enable SW 714101 Tolerance The tolerance level for center decoding allows you to aim the laser close to the bar code to be read rather than be positioned on the bar code 0 No tolerance laser aimer must be positioned on the bar code to be read 100 most permissive laser aimer can be positioned beside the bar code to be read Data decoding securit...

Страница 143: ...e and scan both codes The scanner beeps for each code that is decoded 2 If turn off after good read is enabled the scanner turns off AFTER the last bar code in the sequence is read Compose the number of bar codes for the sequence Data decoding security Bar code sequence 1 SW 714301 Beeps LEDs Note tone frequency Beeps LEDs Note tone frequency high SW 7280082A Beeps LEDs Note tone frequency low SW ...

Страница 144: ...e SW 724000 Beeps LEDs Power up beeps Enable SW 724001 Good read beeps Number Normal bar codes 1 beep default good read Configuration codes 2 beeps good read 6 beeps setup error 3 long beeps EEPROM integrity error contact your Intermec representative Beeps LEDs Good read beeps Number 1 beep SW 724101 Beeps LEDs Good read beeps Number 2 beeps SW 724102 ...

Страница 145: ...724100 Duration Value is in milliseconds Beeps LEDs Good read beeps Duration 60 SW 7281003C Beeps LEDs Good read beeps Duration 80 SW 72810050 Beeps LEDs Good read beeps Duration 200 SW 728100C8 Beeps LEDs Good read beeps Duration 300 SW 7281012C ...

Страница 146: ...ormal IBM OCIA product cable connected Beeps LEDs Good read beeps Timing During transmission SW 724202 Beeps LEDs Good read beeps Timing Before transmission SW 724200 Beeps LEDs Good read beeps Timing After transmission SW 724201 Good read LED duration Read LED green good read Setting a duration of 0 ms no good read LED Value is in milliseconds Beeps LEDs Good read LED duration 80 SW 72820050 ...

Страница 147: ...W 728203E8 Beeps LEDs Good read LED duration 2500 SW 728209C4 Beeps LEDs Good read LED duration 5000 SW 72821388 Disable enable all good read signals This setting can be used to disable all good read signals Beep LED and vibrate Beeps LEDs Disable enable all good read signals Disable SW 725100 ...

Страница 148: ...od read signals Enable SW 725101 Error beep Beeps LEDs Error beep Enable SW 724301 Beeps LEDs Error beep Disable SW 724300 Setup beep and LED Beeps LEDs Setup beep and LED Enable SW 724401 Beeps LEDs Setup beep and LED Disable SW 724400 ...

Страница 149: ...des when using the Multicode function see Symbologies Use this setting to activate beeps when reading bar codes that are part of a Multicode Beeps LEDs Multicode beeps None SW 725000 Beeps LEDs Multicode beeps Good Read Beep SW 725001 Beeps LEDs Multicode beeps Shorter Beep SW 725002 ...

Страница 150: ...1 7 Configuration Modes And Utilities Get version info Get firmware version STR 30C0 Get decode version info Get decode version STR 30C2 Get all component versions Get sub system versions STR 30C4 ...

Страница 151: ...uct to resume normal operation Do not send this command directly from EasySet to your product you must read this command as a configuration code send to the setup sheet and print out See section 1 Using EasySet for details on how to connect up for firmware upgrade with RS 232 cable firmware upgrade with an RS 232 cable CCMD 3001 Optical setup using configuration bar codes Use configuration bar cod...

Страница 152: ...ibit after 1 mn SW 744001 Transparent configuration mode Allows you to use your scanner to set up other products setup commands are transmitted to the other product but do not affect your scanner Read unconcatenated configuration codes from the setup sheet to set up another product in transparent configuration mode not possible with EasySet online Transparent configuration mode Disable SW 744100 T...

Страница 153: ... instructions may cause harmful interference to radio co mmunications However there is no guarantee that interference will not occur in a par ticular installation If this equipment does cause harmful interference to radio or televi sion reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following mea...

Отзывы: