4
At power up lighting and decoding are on.
- After a period of inactivity lasting the time specified by the trigger timeout, the
lighting turns off or is dimmed (depending on the scanner used).
- When a new bar code is presented the lighting and decoding restart and stay
on until another period inactivity.
- The trigger can be used in Presentation mode - when you pull the trigger the
scanner functions as if it were in Level mode.
- Only available with 2D models.
Scanning / Triggering - Triggering modes - Presentation
<SW>704006
Presentation threshold
- Only available on 2D models.
- Use this setting when in Presentation Triggering mode to regulate how
sensitive the imager is to movement which automatically wakes up the
scanner.
- The higher the value = the stronger the movement is needed to wake up the
scanner.
Scanning / Triggering - Presentation threshold - 50 (*)
<SW>704932
Trigger timeout (sec)
- The trigger timeout is used in the following trigger modes:
- Pulse
- Flashing
- Autostand
- Value in seconds