background image

Operation manual of solar water controller SR601 

-------------------------------------------------------------------------------------------------- 

 

~ 12 ~ 

4.Instruction of display illustration

 

 

4.1 Screen display instruction 

 

 

 

 

 

 

 

 

 

 

 

4.2 Code instruction 

 

 

 

 

 

 

 

 

 

 

 

Code 

Code explanation 

E0 

Connection cable between controller and sensor fault  

E4 

Collector pipe high temperature protection 

E6 

Temperature senor fault 

E7 

Water level sensor fault 

Содержание SR601

Страница 1: ...Contents Contents 1 1 Safety information 3 1 1 Installation and commissioning 3...

Страница 2: ...omagnetic valve 7 2 4 1 Faults checking of electromagnetic valve 8 2 5 Installation of water level and temperature sensor 9 2 5 1Installation of Silico Sensor 9 2 5 2 Installation of underside positio...

Страница 3: ...oading 15 5 6 Hot water circulation 15 5 7 Insulation by Tem controlled 16 5 8 Insulation by time controlled 17 6 Protection Function 18 6 1 Collector high temperature protection 18 6 2 Low water pres...

Страница 4: ...tor the compliance with these instructions or the circumstances and methods used for installation operation utilization and maintenance of this controller Improper installation can cause damages to ma...

Страница 5: ...2 Installation 2 1 Installing the controller Note the controller can only be installed in an area having an adequate level of protection Fixing the hang panel of controller Choose a suitable site Mark...

Страница 6: ...pending on the type of installation the cables may enter the device through the rear hole of the case or the lower side hole of the case Cable come from the rear remove the plastic flaps from the rear...

Страница 7: ...must be connected also Inputs T 1 2 3 1 Port T Temperature sensor for heating cable NTC10K 2 Water level and temperature sensor input 1 If silicon sensor B01 or B02 was connected on Port1 connect red...

Страница 8: ...arked on the body of electromagnetic valve Electromagnetic should be installed in the place where is easy to maintain and does not bring other lose please take measures for anti freezing anti sunburn...

Страница 9: ...Whether wire coil of electromagnetic valve has power Measure the resistance with Ohmmeter Change wire coil or change valve if necessary Operation voltage is unstable Measure voltage Change input powe...

Страница 10: ...water level and temperature sensor 2 5 1 Installation of Silico Sensor Insert silicon sensor into overflow outlet of solar tank Tighten the sensor screw Temperature sensor wires connection Red wire co...

Страница 11: ...ide positioned sensor has 2 ways of installation one is upward installed at the collector pipe hole one is upward installed at the bottom of water tank see picture diameter of 47mm and 57mm installed...

Страница 12: ...ration manual of solar water controller SR601 11 3 Introduction of solar system Description this system is water and collector integrated solar water system it is easy for mounting and efficiency is h...

Страница 13: ...ction of display illustration 4 1 Screen display instruction 4 2 Code instruction Code Code explanation E0 Connection cable between controller and sensor fault E4 Collector pipe high temperature prote...

Страница 14: ...or at 50 or 80 position 10 minutes later it starts to load water but in the case when man is using water water level is changing it starts to load water 60 minutes later When water temperature is lowe...

Страница 15: ...ding Functional description Timing load button is used to set the time for triggering the water loading Press Timing load button continuously to set the desired time for triggering water loading adjus...

Страница 16: ...same then water loading will be started after 60 minutes doing like this can avoid water temperature changes so acutely and therefore avoid uncomfortable feeling for customer Press tem Load button co...

Страница 17: ...1o C activate the accompany electrical heating cable P2 When test the temperature T on the pipeline more than turning on temperature 5o C deactivate the accompany electrical heating cable P2 For examp...

Страница 18: ...ot adjustable and then stops for 30minutes can adjustable this process repeats Doing like this can save electricity prolong the lifetime of heating wire and avoid fire accident which caused by aging e...

Страница 19: ...breaking collector pipe which caused by large temperature difference 6 2 Low water pressure protection Functional description During the water loading mode because of low water pressure or no water f...

Страница 20: ...re measuring 0 99 o C Range of temperature display 0 99 o C Can connect loading pump 1pc 600W Can connect electrical heating cable 1pc 800W Ambient temperature 10o C 50o C Water proof grade IP41 Socke...

Страница 21: ...r will exclude the failure caused by production and material selection A correct installation will not lead to failure When a user takes incorrect handling way incorrect installation improper or crud...

Отзывы: