Operation manual of solar water controller SR601
--------------------------------------------------------------------------------------------------
~ 13 ~
5.Functions and Operation
Under cut off power supply,Connection sensors, pump or solenoid
valves to the controller!
5.1
“ON/OFF” button
After power is switched-on, as default set controller is open, and
controller displays water temperature and water level, all functional
buttons are ready for setting operational parameters. After controller is
open, press on/off button, then controller entries into close mode, after
two 2 hours controller recovers to work again.
Automatically water loading under Auto mode:
When water temperature is over 60
o
C
and water level is at 20% position
or at 50% or 80% position
,
10 minutes later it starts to load water, but in
the case when man is using water (water level is changing) it starts to load
water 60 minutes later. When water temperature is lower than 55
o
C
or
when water level raises up to 100% position, then it stops to load water.
When water level drops due to using water, tank appears the status of lack
of water, and then it starts to load water to desired position after 30
minutes.
5.2 Water loading
Functional description:
When water isn’t full in tank, and user wants to start water load
immediately, it can be achieve by press"water load" button to start manual
water loading function
Activate and deactivate function:
► press"water load" button,water loading signal displays. Water level area
blinks,
►press"water load" button continuously to set desired water level ( 50% -
100%)