Operation manual of solar water controller SR601
--------------------------------------------------------------------------------------------------
~ 7 ~
connect red wire
Port2:
connect white wire
Port3:
connect black wire
2.4
Installing electromagnetic valve
Before installing electromagnetic valve, please clean up and wash
pipe.
If water is provided by water tower, please select electromagnetic
valve, which caters the water pressure of water tower. So to avoid the
low flow rate or even no water flows from electromagnetic valve.
Check whether the output voltage of controller caters to the label
voltage of electromagnetic valve; check whether the filter net is
completed, whether the body of electromagnetic valve is completed.
Outlet and inlet of electromagnetic valve should be right installed, the
side with filter net is input, and water flow direction should be same as
the arrow which marked on the body of electromagnetic valve.
Electromagnetic should be
installed in the place where is
easy to maintain and does not
bring other lose, please take
measures for anti-freezing,
anti-sunburn and therefore to
avoid aging of body of valve
and to prolong the lifetime of
valve. Please pay attention to
install the wire coil upwards.
It is forbidden to use wrench to work on the wire coil and on plastic
part. The inlet and outlet pipe of electromagnetic valve should be
keep at a same level, and ensure not to mount valve compulsively
when both connection parts are not at a same level, and therefore to
avoid damaged of valve. It should be not
ed that installed valve doesn’t
bear the torsional strength which caused by wrong mounted pipe.
Two-cores wire should be connected with electromagnetic valve,
when wire need to be prolonged, please select 1.0mm
2
cable.
The pipe, which is connected with valve, should be easy to dismount
or use flexible pipe, it should be easy to clean the filter.